Desa A, B, C - Manual

Desa A, B, C

Desa A, B, C – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
Page: / 40

Table of Contents:

  • Page 2 – TABLE OF CONTENTS; DANGER: Carbon monoxide poisoning may lead; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; WARNINGS; WARNING: Any change to this heater or its controls; OPTIONAL POSITIONING OF
  • Page 3 – SAFETY INFORMATION; Continued; PRODUCT IDENTIFICATION; Figure 1 - Product Identification
  • Page 4 – LOCAL CODES; CAUTION: Do not remove the metal data plates; PROVIDING ADEQUATE VENTILATION; Unusually Tight Construction; PRODUCT FEATURES; OPERATION
  • Page 5 – Confined and Unconfined Space; per kw) of the aggregate input rating; AIR FOR COMBUSTION AND VENTILATION
  • Page 6 – Ventilation Air From Inside Building; Do not provide openings for inlet or outlet air into; Figure 3 - Ventilation Air from Outdoors
  • Page 7 – Vent-free heaters add moisture to the air. Although; CHECK GAS TYPE; LOG SIZING REQUIREMENTS; INSTALLATION
  • Page 8 – Figure 4 - Minimum Clearance for Combustible to Wall; *Minimum 16 inches from Side Wall; Noncombustible; Noncombustible material OK.; Minimum Noncombustible Material Clearances; If Not Using Mantel; Installing Damper
  • Page 9 – Determining Minimum Mantel Clearance; FLOOR CLEARANCES; A. If installing appliance on the floor level, you must maintain; Figure 6 - Minimum Mantel Clearances Without Using Hood; Figure 7 - Minimum Mantel Clearances When Using Hood
  • Page 10 – Area of Various Standard; Chimney; WARNING: You must secure this heater to fire-; Installation Items Needed; Damper; Damper Clamp
  • Page 11 – Mounting Bracket; Remove heater base from fireplace.; Gas Control
  • Page 12 – External Regulator; CONNECTING TO GAS SUPPLY; Figure 15 - External Regulator With Vent Pointing Down; Vent Pointing Down; Install equipment shutoff valve in an accessible
  • Page 13 – WARNING: Test all gas piping and connections; Pressure Testing gas Supply Piping system; Correct all leaks at once.; CHECKING GAS CONNECTIONS
  • Page 14 – Figure 18 - Equipment Shutoff Valve; Open; Pressure Testing Heater Gas Connections; Make sure control knob of heater is in the OFF position.; INSTALLING LOGS; WARNING: Failure to position the parts in accor-
  • Page 15 – Your appliance may vary from model shown but log
  • Page 16 – OPERATING HEATER; WARNING: If you do not follow these instructions; FOR YOUR SAFETY READ; • If fireplace has glass doors, never operate this; Ignitor Electrode; OPERATING HEATER (THERMOSTAT CONTROLLED MODELS); THERMOSTAT-CONTROLLED MODELS
  • Page 17 – Shutting Off Heater; MANUALLY-CONTROLLED MODELS
  • Page 18 – WARNING: Do not operate heater between locked; Control Knob; Shutting Off Burners Only (pilot stays lit)
  • Page 19 – WARNING: Burners will come on automatically; LIGHTING INSTRUCTIONS; WARNING; Figure 29 - Control Knob and Ignitor Button Location
  • Page 20 – CAUTION: Do not try to adjust heating levels by; All remote control accessories must be purchased sepa-; Thermostat Control Operation; OPTIONAL REMOTE OPERATION; Lighting Instructions on page 19.; Do not leave the selector switch in the RE-
  • Page 21 – GHRC Series Operation:; When turning burners off, the pilot will remain lit.; GHRCTA Series Operation:; manual mode when ON is lit.; The hand-held remote control unit must be; To turn the pilot off, manually turn the con-; Flame Adjustment Knob
  • Page 22 – WARNING: If yellow tipping occurs, your heater; If front burner flame pattern is incorrect, as shown in Figure 37; INSPECTING BURNERS; Check pilot flame pattern and burner flame patterns often.; PILOT FLAME PATTERN; If pilot flame pattern is incorrect, as shown in Figure 35; Figure 36 - Correct Front Burner Flame Pattern
  • Page 23 – WARNING: Turn off heater and let cool before; Blow air through the ports/slots and holes in the burner.; LOGS; • If you remove logs for cleaning, refer to Installing Logs, page; Figure 38 - Injector Holder On Outlet Burner Tube
  • Page 24 – POSSIBLE CAUSE; TROUBLESHOOTING
  • Page 25 – OBSERVED PROBLEM
  • Page 26 – IMPORTANT; REMEDY
  • Page 27 – Do not remove the screw. Make sure you tighten the; OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB
  • Page 28 – SPECIFICATIONS
  • Page 29 – When Gas Pressure Is Too Low; TECHNICAL SERVICE; PARTS UNDER WARRANTY; WIRING DIAGRAM; SERVICE HINTS
  • Page 30 – ILLUSTRATED PARTS BREAKDOWN
  • Page 31 – PART NUMBER FOR; PARTS LIST
  • Page 33 – KEY
  • Page 35 – REMOTE-READY VARIABLE CONTROL; PART NUMBERS
  • Page 36 – FIREBOXES; ACCESSORIES; EQUIPMENT SHUTOFF VALVE - GA5010
  • Page 37 – • ACCESSORIES; OWNER'S REGISTRATION FORM
  • Page 38 – Postage
  • Page 39 – NOTES
  • Page 40 – NOT A UPC; KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; LIMITED WARRANTY; For information about this warranty write:
Loading the manual

LO

PILOT

OFF

HI

UNVENTED (VENT-FREE) GAS LOG HEATER

OWNER’S OPERATION AND INSTALLATION MANUAL

Remote-Ready and Variable Manually-Controlled Models

Also Design-Certified As Vented Decorative Appliances

S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .

S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .

WARNING: If the information in this manual
is not followed exactly, a fire or explosion
may result causing property damage, per-
sonal injury, or loss of life.

— Do not store or use gasoline or other

flammable vapors and liquids in the vicinity
of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not

use any phone in your building.

• Immediately call your gas supplier from a

n e i g h b o r ’ s p h o n e . F o l l o w t h e g a s
supplier’s instructions.

• If you cannot reach your gas supplier, call

the fire department.

— Installation and service must be performed

by a qualified installer, service agency, or
the gas supplier.

WARNING: Improper installation, adjust-
ment, alteration, service, or maintenance
can cause injury or property damage. Re-
fer to this manual for correct installation
and operational procedures. For assis-
tance or additional information consult a
qualified installer, service agency, or the
gas supplier.

WARNING: This appliance is for installa-
tion only in a solid-fuel burning masonry
or UL127 factory-built fireplace, or in an
approved ventless firebox. It is design-
certified for these installations in accor-
dance with ANSI Z21.11.2. Exception: Do
not install this appliance in a factory-built
fireplace that includes instructions stat-
ing it has not been tested or should not be
used with unvented gas logs.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which
it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer
to

Air for Combustion and Ventilation section on page 4 of this manual.

F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m

F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m

This appliance may be installed in an aftermarket,* manufactured (mobile) home, where not
prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance
is not convertible for use with other gases.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

("A" Models) 18", 24", and 30"

Remote-Ready

(“C” Models) 18", 24", and 30"

Variable Manually-Controlled

(“B” Models) 18", 24", and 30"

Thermostatically-Controlled

TM

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TABLE OF CONTENTS; DANGER: Carbon monoxide poisoning may lead; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; WARNINGS; WARNING: Any change to this heater or its controls; OPTIONAL POSITIONING OF

104415 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 2 TABLE OF CONTENTS SAFETY INFORMATION ............................................................ 2 PRODUCT IDENTIFICATION ...........

Page 3 - SAFETY INFORMATION; Continued; PRODUCT IDENTIFICATION; Figure 1 - Product Identification

104415 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 3 3 SAFETY INFORMATION Continued PRODUCT IDENTIFICATION Figure 1 - Product Identification 1. This appliance is only for use with the ...

Page 4 - LOCAL CODES; CAUTION: Do not remove the metal data plates; PROVIDING ADEQUATE VENTILATION; Unusually Tight Construction; PRODUCT FEATURES; OPERATION

104415 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 4 LOCAL CODES Install and use heater with care. Follow all local codes. In theabsence of local codes, use the latest edition of The N...