Delta GBR80H - Manual

Delta GBR80H

Delta GBR80H – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual

4405 Cushing Parkway | Fremont, CA 94538 | tel 1.888.979.9889 | www.deltabreez.com

DC Motor Technology

Built -in soft start function to increase bearings life

Automatically

powers OFF when

impeller is locked

abnormally.

Model

Quantity

Comments

Project:

Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:

MODEL GBR

80

H

(80 CFM)

Allows fan to operate in full speed mode or humidity

control mode by manual switch.

For humidity control mode, when humidity is above

the user-adjustable set-point, fan runs at full speed

(80 CFM). When humidity is below the set-point, the

fan runs continuously at a pre-set lower level (0 or

50 CFM).

GreenBuilder GBR

80

H

Continuous low speed

Full speed

Static Pressure (inches w.g.)

0.1

0.25

0.1

0.25

Air Flow (CFM)

50

37

80

68

2

.

1

8

.

0

0

.

1

3

.

0

<

s

e

n

o

S
Power Consumption (Watts)

4.0

6.0

9.7

11.8

Energy Efficiency (CFM/Watt)

12.5

6.1

8.2

5.7

Current (Amps)

0.16 Max

0.22 Max

0

6

/

0

2

1

)

z

H

/

V

(

g

n

it

a

R

r

e

w

o

P

Full Speed:

80 CFM/0.8 Sones @ 0.1 SP, 9.7 Watts

68 CFM/1.2 Sones @ 0.25 SP, 11.8 Watts

Low Speed:

50 CFM/<0.3 Sones @ 0.1 SP, 4.0 Watts

37 CFM/1.0 Sones @ 0.25 SP, 6.0 Watts

%RH

50

50

0

60

70

80

CFM

50ft

40ft

30ft

20ft

10ft

0.90

0.80

0.70

0.60

0.50

0.40

0.30

0.20

0.25

0.10

Ai

r P

ress

ur

e (IN

H

2

O

)

0

0

30.0

60.0

90.0

120.0

150.0

Air Flow (CFM)

Fan Curve

Full Speed

80CFM

Low Speed

50CFM

Description

Low noise ceiling mount ventilating fan, rated for continuous

running. Fan has been awarded ENERGY STAR® Most Efficient in

2014. It is HVI, UL, and cUL certified, and can be used to comply

with ASHRAE 62.2 (local and whole building continuous and

intermittent operation), CA Title 24, and CALGreen requirements.

Motor/Blower

Power rating of 120 volts/60Hz

DC brushless motor engineered to run continuously

Motor equipped with thermal cutoff fuse.

Removable with permanently lubricated plug-in motor

Housing

• Galvanized steel body

• Detachable 4” diameter duct adapter

• Built-in backdraft damper

• Easy installation with expandable extension bracket

Grille

• Attractive design using ABS material

• Attaches directly to housing with torsion springs

LED Indicator

• Blue and amber LED indicator lights to show humidity

sensor and full speed modes

Warranty

• 3-year limited warranty

Features

• Adjustable humidity set points between ~50% to ~80% RH
• Adjustable low speed airflow
• For ceiling mount only, airflow of 80 CFM(±10%) and 0.8 Sones

at 0.1” static pressure

• Power consumption approximately 9.7 Watts with an efficiency

rating approximately 8.2 CFM/Watt at 0.1” static pressure

• UL and cUL listed for tub/shower enclosure when used with

GFCI-protected branch circuit wiring

Control Options

8.0”

8.25”

4.0”

5.75”

10.75"

10.75"