Page 3 - Contents
Technical Guide Book for PowerVault MD3200MD3220 1 Contents Product Overview .......................................................................................................4 6Gb Serial Attached SCSI (SAS 2.0) ......................................................................................
Page 6 - Product Overview; applications and IT environments.
Technical Guide Book for PowerVault MD3200MD3220 4 Product Overview The PowerVault MD3200 is the next generation series of directly connected shared SAS arrays replacing the MD3000 product in the product portfolio. The MD3200 series of arrays provides vastly superior functionality over its predecess...
Page 7 - Controller Architecture
Technical Guide Book for PowerVault MD3200MD3220 5 Key features of SAS 2.0 • 6Gb/s SAS Signaling – doubles the transfer rate from 3Gb to 6Gb • DFE (Decision Feedback Equalization) – increases cable limit to 10m ( 2 – 4 is typical) • Supports SAS mini connectors (SFF-8088 and SFF-8087) • SSC (Spread ...
Page 8 - creating; MD3200 RAID Controller Module View – LEDs; Location LED Term
Technical Guide Book for PowerVault MD3200MD3220 6 the firmware, and protect data until it can be written safely to the hard disk drives. The MD3200’s architecture is designed to excel in multi-host systems environments. Its I/O system core provides built-in hardware XOR for high-speed RAID parity c...
Page 10 - Selected Controller Features; Chassis; Dimensions and Weight
Technical Guide Book for PowerVault MD3200MD3220 8 Table 1. Selected Controller Features Automated I/O path protection with host-based, multipath failover drivers One or more virtual disks per disk group Automatic drive failure detection and rebuild using a global hot spare drive Up to 256 virtual d...
Page 11 - Front View and Features; MD3200 Front View and Features
Technical Guide Book for PowerVault MD3200MD3220 9 Figure 3. MD3200 and MD3220 Dimensions PowerVault™ MD3200: Weight (maximum configuration) 29.3 kg (64.6 lb) PowerVault™ MD3220: Weight (maximum configuration) 24.2 kg (53.4 lb) Front View and Features Figure 4. MD3200 Front View and Features
Page 13 - MD3220 Front Panel Indicators; FRONT PANEL / BEZEL INDICATOR AND FETAURE DESCRIPTION
Technical Guide Book for PowerVault MD3200MD3220 11 Figure 7. MD3220 Front Panel Indicators Table 3. MD3200 and MD3220 Front Panel Feature Description FRONT PANEL / BEZEL INDICATOR AND FETAURE DESCRIPTION Item Indicator, Button, or Connector Icon Description 1 Enclosure status LED The enclosure stat...
Page 15 - Power Supply Indicator Codes; RAID Controller Module 0
Technical Guide Book for PowerVault MD3200MD3220 13 Figure 9. MD3200 and MD3220 Rear View Figure 10. Power Supply Indicator Codes RAID Controller Module 0 RAID Controller Module 1 Power Supply / Cooling Fan Modules
Page 16 - Power Indicator Description; POWER INDICATOR AND FETAURE DESCRIPTION; Hard Drives
Technical Guide Book for PowerVault MD3200MD3220 14 Table 4. Power Indicator Description POWER INDICATOR AND FETAURE DESCRIPTION Item Indicator, Button, or Connector Icon Description 1 DC Power The LED lights green when the DC output voltage is within the limit. If this LED is off, it indicates that...
Page 17 - Supported Drives; Form Factor; from Dell’s factory.
Technical Guide Book for PowerVault MD3200MD3220 15 Table 5. Supported Drives Form Factor Speed (rpm) Capacity (GB) 2.5” SAS HDDs up to 6Gb/s SSDs up to 3Gb/s 7,200 500 GB 10,000 146 GB 300 GB 600GB (post RTS) 15,000 73 GB 146 GB SSD 150 GB 3.5” SAS HDDs up to 6Gb/s 7,200 500 GB 1 TB 2 TB 15,000 300...
Page 18 - Hard Drive Indicators; Hard Drive Indicators (includes HDD and SSD)
Technical Guide Book for PowerVault MD3200MD3220 16 Hard Drive Indicators Figure 11. Hard Drive Indicators (includes HDD and SSD) Table 6. Drive Indicator Description Drive-Status Indicator Pattern (RAID Only) Condition Blinks green two times per second Identify drive/preparing for removal Off Drive...
Page 19 - Storage Capacity Expansion; cable JBODs to the MD32X0 storage arrays.; Expansion and cabling
Technical Guide Book for PowerVault MD3200MD3220 17 Storage Capacity Expansion Both the MD3200 and MD3220 systems are capable of supporting up to 96 total hard drives. Adding additional drives past what the base platforms hold is a simple matter of connecting either MD1200 and/or MD1220 JBODs to the...
Page 20 - SAS Cables; Mini-SAS Cable Transition; Gb SAS HBA
Technical Guide Book for PowerVault MD3200MD3220 18 SAS Cables The MD3200 and MD3220 arrays and the MD1200 and MD1220 JBODs standardize on the 6Gb/s (SAS 2.0) Mini-SAS cable (SFF 8088). The Mini-SAS cable is unique from the SAS cable used with the previous MD3000 array and MD1000 JBOD. Figure 13. Mi...
Page 22 - Enterprise Window; Within the; MD Storage Manager: Enterprise Window; The Enterprise Window; Setup tab window, a user can upgrade
Technical Guide Book for PowerVault MD3200MD3220 20 Enterprise Window The Enterprise Window is the main window that opens when the MD Storage Manager is initially launched. Within the Device tab, it provides a view of all of the storage arrays, including partially managed storage arrays, in the over...
Page 23 - MD Storage Manager: Setup Tab; Clicking the; Devices tab and double-click on a storage array; Array Window; quickly adapt their array to meet their needs.
Technical Guide Book for PowerVault MD3200MD3220 21 Figure 15. MD Storage Manager: Setup Tab There are two ways to select an array to manage from the Enterprise Window. This includes; Clicking the Manage a Storage Array in the Setup tab, then select the desired storage array; or, go to the Devices t...
Page 24 - MD Storage Manager: Array Window; Status
Technical Guide Book for PowerVault MD3200MD3220 22 Figure 16. MD Storage Manager: Array Window The Summary tab (shown above) provides administers with a quick look at all the pertinent information regarding the selected MD3200 or MD3220 storage array as well as links to various management tasks. Th...
Page 25 - MD Storage Manager: Logical Tab
Technical Guide Book for PowerVault MD3200MD3220 23 The Hosts & Mappings area provides information about the number of hosts, virtual disk mappings, and storage partitions that have been configured. There is also a link provided to allow the user to get more detailed information about the hosts ...
Page 26 - Physical tab which will be covered next.; MD Storage Manager: Physical Tab
Technical Guide Book for PowerVault MD3200MD3220 24 component, and selecting “View Associated Physical Components”. This physical view can also be retrieved by selecting the Physical tab which will be covered next. The Physical tab provides both a physical view of the storage array as well as detail...
Page 27 - Mappings window includes both a; MD Storage Manager: Mappings Tab; Topology
Technical Guide Book for PowerVault MD3200MD3220 25 Next, is the Mappings tab which provides an overall view of the host-to-virtual disk mappings configured on the storage array. The Mappings window includes both a Topology pane as well as a Defined Mappings pane. Figure 19. MD Storage Manager: Mapp...
Page 29 - MD Storage Manager: Access to Tasks
Technical Guide Book for PowerVault MD3200MD3220 27 It is important to note that many tasks can also be accessed from the pull down menus across the top; or, by going to the Logical, Physical or Mappings tabs in the Array Window and right-clicking on the appropriate object (i.e. storage array, virtu...
Page 30 - The final tab is the; MD Storage Manager: Support Tab; Gather Support Information; Recovery Guru
Technical Guide Book for PowerVault MD3200MD3220 28 The final tab is the Support tab which provides a central location when storage array recovery, support information or a description of the storage array components are needed. Figure 22. MD Storage Manager: Support Tab Gather Support Information s...
Page 32 - RAID Configuration Support; Virtual Disk Configuration; maximum of 256 virtual disks
Technical Guide Book for PowerVault MD3200MD3220 30 Table 7. RAID Configuration Support RAID-0 RAID-1 and 1+0 RAID-5 RAID-6 Description Data is striped across multiple physical disks. Data is “mirrored” to another physical disk. Physical disks operated independently with data and parity blocks distr...
Page 33 - Configuration Metadata; region; Global Hot Spares; LUN; Logical; Host A
Technical Guide Book for PowerVault MD3200MD3220 31 Configuration Metadata MD3200 series of controllers store configuration metadata in a private 512 MB region on every configured physical disk. This metadata area contains physical disk state and status information, virtual disk state and status inf...
Page 34 - Snapshot; snapshot; Virtual Disk Copy
Technical Guide Book for PowerVault MD3200MD3220 32 application. A given host can concurrently have virtual disks with different capacities, different RAID levels, and different physical disk types. This flexibility enables hosts with different capacity, performance or data protection demands to eff...
Page 35 - Online Administration; attached hosts. Online capabilities include:
Technical Guide Book for PowerVault MD3200MD3220 33 background operation with five user-defined priority settings, enabling administrators to minimize either copy time or the overall I/O impact to the storage system. As virtual disk copy is controller based, it requires no host interaction or CPU cy...
Page 36 - Host Operating System Support; RedHat Enterprise Linux
Technical Guide Book for PowerVault MD3200MD3220 34 transferred to the first controller, its flash memory is updated, and the controller is rebooted. The firmware is then passed from the first controller to the second, and the process is repeated. With a multi- path driver installed, access to all s...
Page 37 - Supported Servers; Environmental; ranging from 100 – 240 V, auto-switching to the sensed line level.
Technical Guide Book for PowerVault MD3200MD3220 35 Table 8. Supported Servers R910 R410 R905 R210 R900 PE2970 R815 PE2950 III R810 PE1950 III R805 T710 R715 T610 R710 T410 R610 T310 R510 PE2900 III Please consult with the MD3200/MD3220 Support Matrix for the most up to date list of supported server...
Page 38 - Power Supply Specifications; AC Characteristics; Thermal management
Technical Guide Book for PowerVault MD3200MD3220 36 Table 9. Power Supply Specifications AC Characteristics INPUT PARAMETER Requirement Input Voltage Range 90 – 264 VAC Input Frequency 47 – 63 Hz Peak Inrush Current 55 A for 10ms or less, 25 A for 10-150ms Power Factor over full AC input range 0.9 @...
Page 39 - Environmental Specifications; One shock pulse in the positive z axis (one pulse on each side of
Technical Guide Book for PowerVault MD3200MD3220 37 Table 10. Environmental Specifications Temperature Operating 10° to 35°C (50° to 95°F) with a maximum temperature gradation of 10°C per hour Note: For altitudes above 2950 feet, the maximum operating temperature is de-rated 1°F/550 ft. Storage -40°...
Page 40 - one or more virtual disks per disk group.
Technical Guide Book for PowerVault MD3200MD3220 38 Configuration Guidelines General Configuration Rules The MD3200 and MD3220’s extensive configuration flexibility enables customized performance tuning, maximum capacity utilization and the highest data protection to support application servers with...