Page 4 - S60 Specifications
4 | www.d e ll .co m | s u p po rt.d ell .co m Access the RJ-45 Console Port (RS-232). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Access the RJ-45 Console Port with a DB-9 Adapter . . . . . . . . . . . . . . . . . . . . 29 Access the USB-B Console Port. . . . . . . . . . . . ...
Page 5 - About this Guide; for software; Related Publications
About this Guide | 5 1 About this Guide This guide provides site preparation recommendations, step-by-step procedures for rack mounting and desk mounting, inserting optional modules, and connecting to a power source. After you have completed the hardware installation and power-up of the S60 system, ...
Page 6 - The S60 System; Introduction; The front of the S60 (
The S60 System | 6 2 The S60 System Introduction The Dell Networking S60 system is a high-performance, high-capacity, low-cost, stackable, Layer 2 switch/Layer 3 router that supports 44 built-in 10/100/1000 Base-T ports, four Small Form-Factor Pluggable (SFP) ports, an optional Small Form-Factor Plu...
Page 7 - Orderable S60 Systems
The S60 System | 7 Orderable S60 Systems You can order the S60 in several different configurations. You can order optional modules separately. To successfully install the S60 system, ensure that you have the following: • S60 chassis (or multiple chassis, if stacking) • At least one grounded AC or DC...
Page 8 - Features; show; FTOS Command Line Reference Guide for the S60 System; LED Displays
The S60 System | 8 Features The S60 offers the following: • S60 CPU and switch processor • Up to 12 stacked systems • Stackable switch features • 19-inch rack-mountable • Standard 1U chassis height • Hot-swappable optional modules, PSUs, and fan modules • Integrated PSU/fan module (three fans per mo...
Page 10 - In addition to the system LEDs, each port has status indicator LEDs.
The S60 System | 10 In addition to the system LEDs, each port has status indicator LEDs. Table 2-2 lists the port LED displays. Table 2-2. Port LED Displays Feature Description 10/100/1000 Port LEDs • Link LED (on the left side of each port): Green—1000M Yellow—10/100M Off—No link • Activity LED (on...
Page 11 - Install the S60 System; This chapter describes the installation procedures as follows:; Install the S60 System in a Rack or Cabinet; Attach the Mounting Brackets
Install the S60 System | 11 3 Install the S60 System To install the S60 system, Dell Force10 recommends completing the installation procedures in the order presented in this chapter. Always handle the S60 system and its components with care. Avoid dropping the system or its Field Replaceable Units (...
Page 12 - To attach the brackets to the chassis, follow these steps:; Install the Chassis into the Rack or Cabinet
Install the S60 System | 12 To attach the brackets to the chassis, follow these steps: Install the Chassis into the Rack or Cabinet To permit access and airflow, ensure that there is adequate clearance surrounding the rack or within the cabinet. When you install two S60 systems near each other, to p...
Page 13 - Attach the Ground Cable; To connect the ground cable to the system, follow these steps:
Install the S60 System | 13 Attach the Ground Cable The S60 system is shipped with two 10-32 screws to attach a ground cable to the system. The cable is not included. To properly ground the system, Dell Networking recommends using a 6AWG two-hole lug, #10 hole size, 63" spacing (not included). T...
Page 14 - Insert Optional Modules; lists the optional
Install the S60 System | 14 Insert Optional Modules The S60 system has expansion slots at the front left and rear right of the system that you can use for stacking modules or for Small Form-Factor Pluggable Plus (SFP+) devices. Table 3-1 lists the optional modules that you can install into these exp...
Page 15 - Install the SFP and SFP+ Optics; To install SFP or SFP+ optics into an open port, follow these steps:; and; Important Points to Know; To connect the systems, use only the supported stacking cables.
Install the S60 System | 15 Install the SFP and SFP+ Optics In addition to the optional SFP+ optical modules, the S60 system has four Small Form-Factor Pluggable (SFP) optical ports in the front of the system. WARNING: ESD damage can occur if the components are mishandled. Always wear an ESD-prevent...
Page 16 - or
Install the S60 System | 16 Figure 3-1. S60 Stacking Topology with 2-port, 12G Stacking Modules Figure 3-2. S60 Stacking Topology with 1-port, 24G Stacking Modules While the diagram shows A-to-B connections, the ports are bi-directional so you can connect A-to-A or B-to-B, as shown in the examples o...
Page 17 - Connect Two S60 Systems
Install the S60 System | 17 Connect Two S60 Systems 2-port, 12G Stacking Modules As an option, when using the 2-port, 12G stacking modules, insert a second cable into the other open stack ports ( Figure 3-4 ). The second cable provides both backup connectivity and increased data transfer between the...
Page 18 - Connect Three or More S60 Systems
Install the S60 System | 18 Connect Three or More S60 Systems 2-port, 12G Stacking Modules As an option, when using the 2-port, 12G stacking modules, insert a second cable into the other open stack ports ( Figure 3-5 ). The second cable provides both backup connectivity and increased data transfer b...
Page 19 - Supply Power and Power Up the System; the equipment rack is properly mounted and grounded.; Power Up Sequence
Install the S60 System | 19 Figure 3-6. Three S60 Systems with 1-port, 24G Stacking Modules Connected in a Ring Topology Supply Power and Power Up the System Supply power to the S60 system after you have mounted them in a rack (or on a table) and have installed the optional modules. Dell Networking ...
Page 20 - AC Power; Connect the plug to each AC receptacle (; DC Power; To connect DC power (
Install the S60 System | 20 The PWR Light Emitting Diode (LED) blinks until the boot-up sequence is complete. When the boot up is complete, the PWD LED is steadily lit. The Stack ID LED displays a digit to show the position of the unit in a stacking chain. For a single chassis, a 0 displays. AC Powe...
Page 21 - Hot-swap Units in a Stack; unit number renumber
Install the S60 System | 21 Hot-swap Units in a Stack You can add, remove, or swap units in an existing stack. The units in the stack and the new units can be already powered up or they can be powered down. All units in a stack must run the same version of the operating system. If you attempt to att...
Page 22 - Power Supplies; Chapter 5, Fans and Filters; Components; AC power supply with integrated fans
Power Supplies | 22 4 Power Supplies The S60 system is designed to support two hot-swappable power supply units (PSUs) with integrated fans that provide the cooling for the system. There are two types of power supplies (AC or DC) and there are two airflow directions (normal and reverse). Two PSUs ar...
Page 23 - Install an AC or DC Power Supply
Power Supplies | 23 Figure 4-2. DC Power Supply Power supply 0 (PSU0) is on the left side of the system; power supply 1 (PSU1) is on the right side of the system. Install an AC or DC Power Supply The PSUs in the S60 system are field replaceable. When both PSUs are up and running, you can remove one ...
Page 24 - Replace an AC or DC Power Supply
Power Supplies | 24 Replace an AC or DC Power Supply NOTE: If a PSU fails, you must completely replace it. There are no field servicable components in the PSU. To request a hardware replacement, refer to Chapter 8, Technical Support . To replace a PSU, follow these steps: 6 For DC PSUs, replace the ...
Page 25 - Fans and Filters; Reverse—airflow is from the PSU to the I/O panel
Fans and Filters | 25 5 Fans and Filters The S60 system comes from the factory with one Power Supply Unit (PSU) and one fan module installed in the system ( Figure 5-1 ). If a second (redundant) PSU is installed and running, both the fan module and the integrated fan/PSU are hot-swappable. With redu...
Page 26 - S60 Fan module; Install a Fan Module; Chapter 4, Power Supplies; Replace a Fan Module; Grab Handle
Fans and Filters | 26 Components • S60 Fan module • S60 Fan module - Reverse flow • S60 Fan filter • The fan filters are used on the reverse flow (R) fan modules only. Figure 5-1. The S60 Fan Module Module slot 0 is on the left side of the system; module slot 1 is on the right side of the system. In...
Page 27 - To replace a fan module, follow these steps:; Install a Fan Filter; To install a fan filter, follow these steps:
Fans and Filters | 27 Error messages appear when the fan tray is removed and when the temperature approaches the threshold. • When a fan tray is removed, the system displays the following message: 00:00:37: %STKUNIT0-M:CP %CHMGR-2-FAN_TRAY_BAD: Major alarm: fan tray 0 in unit 0 is missing or down • ...
Page 28 - Access the Console Ports; For the console port pin assignments, refer to
Access the Console Ports | 28 6 Access the Console Ports You can access the S60 system directly through the console port at rear of the system ( Figure 6-1 ). Access the RJ-45 Console Port (RS-232) NOTE: Before starting this procedure, be sure you have a terminal emulation program already installed ...
Page 29 - Access the RJ-45 Console Port with a DB-9 Adapter; lists the pin assignments.; Access the USB-B Console Port
Access the Console Ports | 29 Access the RJ-45 Console Port with a DB-9 Adapter If the DTE has a DB-9 interface, you can connect to the console port using an RJ-45 to DB-9 adapter along with the RJ-45 rollover cable. Table 6-1 lists the pin assignments. Access the USB-B Console Port The S60 system h...
Page 31 - This chapter the following sections:; Chassis Physical Design; Environmental Parameters
S60 Specifications | 31 7 S60 Specifications This chapter the following sections: • Chassis Physical Design • Agency Compliance Chassis Physical Design Environmental Parameters AC Power Requirements Parameter Specifications Height 1.7 inches (4.3 cm) Width 17.32 inches (44.0 cm) Depth 16.73 inches (...
Page 32 - DC Power Requirements; Agency Compliance; Network Equipment Building Systems (NEBS) Compliance
S60 Specifications | 32 DC Power Requirements IEEE Standards The S60 complies with the following IEEE standards: • 802.3ae 10 Gigabit Ethernet • 802.3ab 1000Base-T • 802.1p L2 Prioritization • 802.1Q VLAN Tagging, Double VLAN Tagging (Q in Q), GVRP • 802.1s Multiple Spanning Tree Protocol • 802.1w R...
Page 33 - USA Federal Communications Commission (FCC) Statement
S60 Specifications | 33 WARNING: Electrostatic discharge (ESD) damage can occur if the components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the S60 system and its components. CAUTION: The intra-building port(s) of the equipment or sub-assembly is suitable...
Page 34 - European Union EMC Directive Conformance Statement; European Community Contact; For regulatory compliance, refer to; Japan: VCCI Compliance for Class A Equipment
S60 Specifications | 34 European Union EMC Directive Conformance Statement This product is in conformity with the protection requirements of EU Council Directive 2004/108/EC on the approximation of the laws of the Member States relating to electromagnetic compatibility. Dell Networking cannot accept...
Page 35 - Korea Compliance; China Compliance
S60 Specifications | 35 Korea Compliance Korea Information China Compliance Safety Standards and Compliance Agency Certifications • CUS UL 60950-1, 1st Edition • CSA 60950-1-03, 2nd Edition • EN 60950-1, 2nd Edition • EN 60825-1, 1st Edition • EN 60825-1 Safety of Laser Products—Part 1: Equipment Cl...
Page 36 - Product Recycling and Disposal
S60 Specifications | 36 • EN 60825-2 Safety of Laser Products—Part 2: Safety of Optical Fibre Communication Systems • FDA Regulation 21CFR 1040.10 and 1040.11 • IEC 60950-1, 2nd Ed, including all National Deviations and Group Differences Electromagnetic Compatibility (EMC) Emissions • International:...
Page 37 - Contacting; SD Card Removal; To remove the SD card, follow these steps:
S60 Specifications | 37 Figure 7-1. The European WEEE symbo l In accordance with the European WEEE Directive, electrical and electronic equipment (EEE) is to be collected separately and to be reused, recycled, or recovered at end of life. Users of EEE with the WEEE marking per Annex IV of the WEEE D...
Page 38 - Battery Replacement and Recycling; To remove the battery, follow these steps:
S60 Specifications | 38 Battery Replacement and Recycling CAUTION: The lithium battery is not field replaceable. Only authorized personnel should remove and replace the lithium battery. If the battery requires replacement, contact Dell Networking Technical Support. WARNING: ESD damage can occur if t...
Page 40 - Perchlorate Material; — Special handling may apply.
S60 Specifications | 40 For California: Perchlorate Material — Special handling may apply. See: http://www.dtsc.ca.gov/hazardouswaste/perchlorate The foregoing notice is provided in accordance with California Code of Regulations Title 22, Division 4.5 Chapter 33. Best Management Practices for Perchl...
Page 41 - Technical Support; This appendix contains the following sections:; The iSupport Website; Accessing iSupport Services; The URL for iSupport is
Technical Support | 41 8 Technical Support This appendix contains the following sections: • The iSupport Website • Contacting the Technical Assistance Center • Requesting a Hardware Replacement The iSupport Website iSupport provides a range of documents and tools to assist you with effectively using...
Page 42 - Contacting the Technical Assistance Center
Technical Support | 42 Contacting the Technical Assistance Center How to Contact Dell Networking TAC Log in to iSupport at http://support.dell.com/force10 and select the Service Request tab. Information to Submit When Opening a Support Case • Your name, company name, phone number, and E-mail address...
Page 43 - Requesting a Hardware Replacement; To request replacement hardware, follow these steps:
Technical Support | 43 Requesting a Hardware Replacement To request replacement hardware, follow these steps: Step Task 1 Determine the part number and serial number of the component. To list the numbers for all components installed in the chassis, use the show hardware command. 2 Request a Return M...