Page 3 - Contents; About this Guide
| 3 Contents 1 About this Guide Related Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2 The S6000-Open Networking (ON) System Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 7 - desk mounting, and connecting to a power source.; Related Publications; For more information about the S6000-ON system, refer to the
About this Guide | 7 1 About this Guide This guide provides site preparation recommendations, step-by-step procedures for rack mounting and desk mounting, and connecting to a power source. CAUTION: To avoid electrostatic discharge (ESD) damage, wear grounding wrist straps when handling this equipmen...
Page 9 - Introduction; the PSU and fan modules.
The S6000-Open Networking (ON) System | 9 2 The S6000-Open Networking (ON) System This chapter contains general features, capabilities, and physical configurations the S6000-ON supports. Introduction The S6000-ON is a fully featured switch/router one rack unit (RU) system where you require 10Gb and/...
Page 10 - Features
10 | The S6000-Open Networking (ON) System www.dell.com | support.dell.com Figure 2-2. S6000-ON I/O-Side View 1 - System LED 2 - Thirty-two QSFP+ Ports 3 - Serial Console 4 - Reset 5 - Stack ID 6 - USB-A 7 - USB-B Console 8 - Management NOTE: The system light emitting diodes (LEDs) are on the I/O si...
Page 11 - Physical Dimensions; The S6000-ON has the following physical dimensions:; Chassis Ports; You can view S6000-ON status information with the system LEDs.; LED Displays; As shown in
The S6000-Open Networking (ON) System | 11 Physical Dimensions The S6000-ON has the following physical dimensions: • 434 x 460 x 43.5 mm (W x D x H) • 17.09 x 18.11 x 1.71 inches (W x D x H) Chassis Ports The following is a list of the standard ports located on each S6000-ON chassis: • Serial RS-232...
Page 12 - Basic Installation Requirements; Site Location and Preparation
12 | The S6000-Open Networking (ON) System www.dell.com | support.dell.com 1 - Serial Console 2 - Master LED 3 - Power LED 4 - Fan Status LED 5 - Locator LED 6 - Stack ID 7 - USB-A 8 - USB-B Console 9 - Management Basic Installation Requirements Detailed installation instructions for the S6000-ON ar...
Page 13 - Orderable S6000-ON Components
The S6000-Open Networking (ON) System | 13 Optional components for installation: • Additional power supply units • Additional fan modules • Additional mounting brackets (if installing in a 4-post rack or cabinet) Orderable S6000-ON Components You can order the S6000-ON system in several different co...
Page 15 - Site Selection
Site Location and Preparation | 15 3 Site Location and Preparation The S6000-ON is suitable for installation as part of a common bond network (CBN). It can be installed in: • Network telecommunication facilities • Data centers • Other locations where the national electric code (NEC) applies This cha...
Page 16 - Cabinet Placement; Fans and Airflow; Fan Combinations; the fans is done as part of the factory install based on SKU type.
16 | Site Location and Preparation www.dell.com | support.dell.com Cabinet Placement Install the S6000-ON only in indoor cabinets designed for use in a controlled environment as described in Site Selection . Do not install the S6000-ON in outside plant cabinets. The cabinet must meet the following: ...
Page 17 - Power; Follow these storage guidelines:
Site Location and Preparation | 17 Power To connect the chassis to the applicable power source, use the appropriate power cord with the S6000-ON system. An AC power cord (country/region specific) is included with the system. When installing AC systems, follow the requirements of the National Electri...
Page 19 - Package Contents; Two sets of rail kits (no tools required)
Install the S6000-ON | 19 4 Install the S6000-ON To install the S6000-ON system, Dell Networking recommends completing the installation procedures in the order presented in this chapter. Always handle the S6000-ON and its components with care. Avoid dropping the system or its field replaceable units...
Page 20 - Unpacking Steps; Open the container or remove the container top.; Install Rack or Cabinet Hardware; Rack Mount Safety Considerations
20 | Install the S6000-ON www.dell.com | support.dell.com • At least one AC power cord (country/region specific) • Getting Started Guide • Safety and Regulatory Information • Warranty and Support Information Unpacking Steps 1 Place the container on a clean, flat surface and cut all straps securing t...
Page 21 - Installing the Dell ReadyRails System
Install the S6000-ON | 21 • Reliable earthing — Maintain reliable earthing of rack-mounted equipment. Pay particular attention to the supply connections other than the direct connections to the branch circuit, for example: use of power strips. • Do not mount the equipment with the rear panel facing ...
Page 24 - Configure a Four-Post Thread
24 | Install the S6000-ON www.dell.com | support.dell.com Configure a Four-Post Thread Step Task 1 For this configuration, remove the flange ear castings from each end of the ReadyRails assemblies. To remove the two screws from each flange ear and remove each casting, use a Torx driver. Refer to Fig...
Page 25 - Installing the S6000-ON System; Installing a 1U Front-Rack; You must configure the rails that are attached to the system.
Install the S6000-ON | 25 Installing the S6000-ON System You can mount the system in the 1U front-rack or 1U two-post (flush and center) configurations. The following is an example of a front-rack configuration. For the 1U two-post (flush and center) configurations, slide the system into the rails i...
Page 26 - To connect the ground cable to the system, follow these steps:
26 | Install the S6000-ON www.dell.com | support.dell.com Attaching the Ground Cable (Optional) To attach the ground cable to the chassis, use a single M4x0.7 screw. The cable itself is not included with the S6000-ON. To properly ground the chassis, Dell Networking recommends using a 6AWG one-hole l...
Page 27 - Installing an AC Power Supply
Install the S6000-ON | 27 Installing an AC Power Supply The S6000-ON supports two hot-swappable PSUs with integrated fans that provide cooling for the system. The S6000-ON supports AC power supplies with two air-flow directions (I/O to PSU or PSU to I/O). Two PSUs are required for full redundancy, b...
Page 29 - Installing QSFP+ Optics; To install QSFP+ optics into an open port, follow these steps:; Removing QSFP+ Optics; Power Up the S6000-ON System; Supply power to the S6000-ON after it is mounted in a rack or cabinet.
Install the S6000-ON | 29 Installing QSFP+ Optics The S6000-ON has thirty-two 40Gbps QSFP+ optical ports. . WARNING: ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the S6000-ON and its components. . WARNING: When working with...
Page 30 - Power Up Sequence; system continues to boot up.
30 | Install the S6000-ON www.dell.com | support.dell.com Power Up Sequence When the system powers up, the fans immediately come on at high speed. The fan speed slows as the system continues to boot up.
Page 31 - Power Supplies; Components; The following power supply options are available for the S6000-ON:
Power Supplies | 31 5 Power Supplies The S6000-ON supports two hot-swappable PSUs with integrated fans that provide cooling for the system. The S6000-ON supports AC power supplies with two air-flow directions (I/O to PSU and PSU to I/O). Two PSUs are required for full redundancy, but the system will...
Page 32 - The PSUs are in a single piece with the PSU fans (see; To install an AC power supply, follow these steps:
32 | Power Supplies www.dell.com | support.dell.com The PSUs are in a single piece with the PSU fans (see Figure 5-1 ). You can replace the fan trays individually, but you cannot replace the fans that are integrated in the PSUs—if the fans integrated in the PSU fail, you must replace the entire PSU....
Page 33 - Replacing an AC Power Supply; After Installing the S6000-ON; party operating system documentation to configure your system.
Power Supplies | 33 Replacing an AC Power Supply Caution: Disconnect the power cord before removing the power supplies. Also, disconnect all power cords before servicing. NOTE: The PSU slides into the slot smoothly. Do not force a PSU into a slot as this may damage the PSU or the S6000-ON chassis. N...
Page 35 - Fans; done as part of the factory install based on SKU type.
Fans | 35 6 Fans The S6000-ON comes from the factory with two PSUs and three fan modules installed in the chassis (see Figure 6-1 ). The S6000-ON has SKUs that support the following configurations. Installation of the fans is done as part of the factory install based on SKU type. • AC PSU with fan a...
Page 36 - Installing a Fan Module; module slot 2 is on the right side of the chassis.; Replacing a Fan Module
36 | Fans www.dell.com | support.dell.com Installing a Fan Module The fan modules in the S6000-ON are field replaceable. Module slot 0 is on the left side of the chassis; module slot 2 is on the right side of the chassis. Replacing a Fan Module CAUTION: DO NOT mix airflow directions. All fans must u...
Page 37 - Management Ports; Accessing the RS-232 Console Port
Management Ports | 37 7 Management Ports Besides the 10Gigabit and 40Gigabit switch ports, the S6000-ON provides several ports for management and storage. Accessing the RS-232 Console Port NOTE: Before starting this procedure, be sure that your PC has a 9-pin serial port and that you have a terminal...
Page 38 - Accessing the Console Port; Accessing the USB-B Console Port; No parity
38 | Management Ports www.dell.com | support.dell.com Accessing the Console Port Accessing the USB-B Console Port The terminal settings are the same for the USB-B port and the console port: • 115200 baud rate • No parity • 8 data bits • 1 stop bit • No flow control When you connect the USB-B port, i...
Page 41 - Specifications; This chapter contains the following sections:; Chassis Physical Design
Specifications | 41 8 Specifications This chapter contains the following sections: • Chassis Physical Design • Environmental Parameters • Power Requirements • IEEE Standards • Agency Compliance Caution: Operate the product at an ambient temperature not higher than 40°C. Lithium Battery Caution: Ther...
Page 42 - Power Requirements; AC Input Specification; IEEE Standards; The S6000-ON system complies with the following IEEE standards:; Agency Compliance; USA Federal Communications Commission (FCC) Statement
42 | Specifications www.dell.com | support.dell.com Power Requirements The following represents the PSU’s capabilities and does not represent S6000-ON operation. AC Input Specification IEEE Standards The S6000-ON system complies with the following IEEE standards: • 802.3ab Gigabit Ethernet (1000BASE...
Page 43 - Canadian Department of Communication Statement; Japan: VCCI Compliance for Class A Equipment
Specifications | 43 Canadian Department of Communication Statement European Union EMC Directive Conformance Statement This product is in conformity with the protection requirements of EU Council Directive 2004/108/EC on the approximation of the laws of the Member States relating to electromagnetic c...
Page 44 - Korean Certification of Compliance; Safety Standards and Compliance Agency Certifications
44 | Specifications www.dell.com | support.dell.com Korean Certification of Compliance Korean Package Label Safety Standards and Compliance Agency Certifications • CUS UL 60950-1, 2nd Edition • CSA 60950-1-03, 2nd Edition • EN 60950-1:2006 +A1:2010+A11:2009 +A12:2011/IEC 60950-1:2005 EN 62311:2008 •...
Page 45 - Product Recycling and Disposal
Specifications | 45 Electromagnetic Compatibility (EMC) Emissions • International: CISPR 22: 2006, Class A • Australia/New Zealand: AS/NZS CISPR 22:2009, Class A • Canada: ICES-003, Issue-4, Class A • Europe: EN55022 2006 (CISPR 22: 2006), Class A • Japan: V3/2012.04 Class A • USA: FCC CFR47 Part 15...
Page 47 - Technical Support; The iSupport Website; Accessing iSupport Services; The URL for iSupport is
Technical Support | 47 9 Technical Support This chapter contains the following sections: • The iSupport Website • Contacting the Technical Assistance Center • Requesting a Hardware Replacement The iSupport Website iSupport provides a range of documents and tools to assist you with effectively using ...
Page 48 - Contacting the Technical Assistance Center; To request replacement hardware, follow these steps:
48 | Technical Support www.dell.com | support.dell.com Contacting the Technical Assistance Center Requesting a Hardware Replacement To request replacement hardware, follow these steps: How to Contact Dell Networking TAC Log in to iSupport at http://www.dell.com/support/my-support and select the Serv...