Dayton 3VG79B - Manual
Dayton 3VG79B – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Dayton Operating Instructions and Parts Manual; Product Identification; Thermostat Knob; General Safety Information; IMPORTANT; : Every possible circumstance; Side Cover
- Page 4 – Fuels; Theory of Operation; THE FUEL SYSTEM; Figure 3 - Cross Section Operational View; Assembly; TOOLS NEEDED; Figure 4 - Wheel and Handle Assembly
- Page 5 – Square Feet; Ventilation; Figure 5 - Upper Shell Removal; Screw
- Page 6 – Figure 6 - Fan Cross Section; PUMP PRESSURE ADJUSTMENT; Operation; Figure 8 - Pressure Gauge Plug Removal; FUEL FILTER
- Page 7 – Figure 10 - Fuel Filter Removal; IGNITOR
- Page 8 – Figure 13 - Ignitor Replacement; NOZZLE ASSEMBLY; Ignitor; Figure 15 - Nozzle and Nozzle Adapter; Nozzle; PUMP ROTOR; Figure 16 - Rotor Location
- Page 9 – Sandpaper; Figure 18 - Sanding Rotor; Fuse; Preventative Maintenance Schedule; How Often
- Page 10 – Please provide following information:; Figure 20 - Motor and Pump Assembly
- Page 11 – Replacement Parts List - Motor and Pump Assembly - Figure 20
- Page 12 – Figure 23 - Replacement Parts Illustration
- Page 13 – Replacement Parts List
- Page 14 – Replacement Parts List for Handle and Wheel Group; Part; Maintenance Kits; Part Numbers; Accessories; Figure 24 - Handle and Wheel Assembly; Wiring Diagram
- Page 15 – Troubleshooting Chart; Corrective Action; Ignition Control Assembly,
- Page 16 – NOT A UPC; LIMITED WARRANTY; LIMITATION OF LIABILITY.
Operating Instructions & Parts Manual
3VG79B
Dayton Portable Forced
Air Heater
Description
Dayton Model 3VG79B is a 200,000 Btu/Hr heater. This heater uses only Kerosene
or No. 1 fuel oil for combustion and electricity to run the motor. It is primarily
intended for indoor and outdoor temporary heating of well-ventilated buildings
under construction, alteration, or repair. It may be used in agricultural, industrial,
and commercial environments.
®
Form 5S4068
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Unpacking
1. Remove all packing items supplied
with heater for shipment.
2. Remove all items from carton.
3. Check items for any shipping
damage. If heater is damaged,
promptly inform dealer where you
bought heater.
Figure 1 - Model 3VG79B
ARL LOGO
G 004
®
Amperage
Electrical Input
(during normal run)
120 Volt/60 Hertz
3.6
ELECTRICAL SPECIFICATIONS
GENERAL SPECIFICATIONS
Output
Hot Air Output
Fuel Tank Capacity
Fuel Consumption
Rating Btu
(CFM Approx)
Fuel
(U.S. Gallons)
(U.S. Gallons/Hr.)
200,000
600
Kerosene or No. 1 fuel oil
13.5
1.4
Air Pump
Heater Weight
Heater Weight
Motor RPM
Pressure (psi)
(Pounds - with fuel)
(Pounds - without fuel)
3400
6.2
77
66
Version B - For Reduction
G016.J
®
Printed in U.S.A.
03430
0700/256/VCPVP
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Dayton Operating Instructions and Parts Manual 2 Dayton PortableForced Air Heater ® 3VG79B Figure 2 - Model 3VG79B Product Identification Thermostat Knob General Safety Information Make certain you read and understandall warnings. Keep these instructions forreference. They are your guide to safeand ...
Dayton Operating Instructions and Parts Manual 4 Dayton PortableForced Air Heater ® 3VG79B Fuels Use only Keroseneor No. 1 fuel oil to avoid risk of fire or explosion. Never usegasoline, naphtha, paint thinners,alcohol, or other highly flammable fuels. Do not use heavy fuels such as No. 2 fueloil or...
Dayton Operating Instructions and Parts Manual 5 Model 3VG79B Version B - For Reduction G016.J ® 4. Place handles on top of fuel tank flange. Insert screws through handles,fuel tank flange, and wheel supportframe. Attach nut finger tight afterinserting each screw. 5. After inserting all screws, tigh...