Dayton 3VG79B - Manual

Dayton 3VG79B

Dayton 3VG79B – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 2 – Dayton Operating Instructions and Parts Manual; Product Identification; Thermostat Knob; General Safety Information; IMPORTANT; : Every possible circumstance; Side Cover
  • Page 4 – Fuels; Theory of Operation; THE FUEL SYSTEM; Figure 3 - Cross Section Operational View; Assembly; TOOLS NEEDED; Figure 4 - Wheel and Handle Assembly
  • Page 5 – Square Feet; Ventilation; Figure 5 - Upper Shell Removal; Screw
  • Page 6 – Figure 6 - Fan Cross Section; PUMP PRESSURE ADJUSTMENT; Operation; Figure 8 - Pressure Gauge Plug Removal; FUEL FILTER
  • Page 7 – Figure 10 - Fuel Filter Removal; IGNITOR
  • Page 8 – Figure 13 - Ignitor Replacement; NOZZLE ASSEMBLY; Ignitor; Figure 15 - Nozzle and Nozzle Adapter; Nozzle; PUMP ROTOR; Figure 16 - Rotor Location
  • Page 9 – Sandpaper; Figure 18 - Sanding Rotor; Fuse; Preventative Maintenance Schedule; How Often
  • Page 10 – Please provide following information:; Figure 20 - Motor and Pump Assembly
  • Page 11 – Replacement Parts List - Motor and Pump Assembly - Figure 20
  • Page 12 – Figure 23 - Replacement Parts Illustration
  • Page 13 – Replacement Parts List
  • Page 14 – Replacement Parts List for Handle and Wheel Group; Part; Maintenance Kits; Part Numbers; Accessories; Figure 24 - Handle and Wheel Assembly; Wiring Diagram
  • Page 15 – Troubleshooting Chart; Corrective Action; Ignition Control Assembly,
  • Page 16 – NOT A UPC; LIMITED WARRANTY; LIMITATION OF LIABILITY.
Loading the manual

Operating Instructions & Parts Manual

3VG79B

Dayton Portable Forced
Air Heater

Description

Dayton Model 3VG79B is a 200,000 Btu/Hr heater. This heater uses only Kerosene
or No. 1 fuel oil for combustion and electricity to run the motor. It is primarily
intended for indoor and outdoor temporary heating of well-ventilated buildings
under construction, alteration, or repair. It may be used in agricultural, industrial,
and commercial environments.

®

Form 5S4068

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.

Unpacking

1. Remove all packing items supplied

with heater for shipment.

2. Remove all items from carton.

3. Check items for any shipping

damage. If heater is damaged,
promptly inform dealer where you
bought heater.

Figure 1 - Model 3VG79B

ARL LOGO

G 004

®

Amperage

Electrical Input

(during normal run)

120 Volt/60 Hertz

3.6

ELECTRICAL SPECIFICATIONS

GENERAL SPECIFICATIONS

Output

Hot Air Output

Fuel Tank Capacity

Fuel Consumption

Rating Btu

(CFM Approx)

Fuel

(U.S. Gallons)

(U.S. Gallons/Hr.)

200,000

600

Kerosene or No. 1 fuel oil

13.5

1.4

Air Pump

Heater Weight

Heater Weight

Motor RPM

Pressure (psi)

(Pounds - with fuel)

(Pounds - without fuel)

3400

6.2

77

66

Version B - For Reduction

G016.J

®

Printed in U.S.A.
03430
0700/256/VCPVP

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Dayton Operating Instructions and Parts Manual; Product Identification; Thermostat Knob; General Safety Information; IMPORTANT; : Every possible circumstance; Side Cover

Dayton Operating Instructions and Parts Manual 2 Dayton PortableForced Air Heater ® 3VG79B Figure 2 - Model 3VG79B Product Identification Thermostat Knob General Safety Information Make certain you read and understandall warnings. Keep these instructions forreference. They are your guide to safeand ...

Page 4 - Fuels; Theory of Operation; THE FUEL SYSTEM; Figure 3 - Cross Section Operational View; Assembly; TOOLS NEEDED; Figure 4 - Wheel and Handle Assembly

Dayton Operating Instructions and Parts Manual 4 Dayton PortableForced Air Heater ® 3VG79B Fuels Use only Keroseneor No. 1 fuel oil to avoid risk of fire or explosion. Never usegasoline, naphtha, paint thinners,alcohol, or other highly flammable fuels. Do not use heavy fuels such as No. 2 fueloil or...

Page 5 - Square Feet; Ventilation; Figure 5 - Upper Shell Removal; Screw

Dayton Operating Instructions and Parts Manual 5 Model 3VG79B Version B - For Reduction G016.J ® 4. Place handles on top of fuel tank flange. Insert screws through handles,fuel tank flange, and wheel supportframe. Attach nut finger tight afterinserting each screw. 5. After inserting all screws, tigh...

Other Dayton Models

All Dayton Other