Table of Contents:
- Page 2 – Dayton Installation, Operation, Maintenance and Parts Manual; Dayton High Intensity Heaters; Limited Warranty
- Page 3 – Safety Symbols; Commercial / Industrial; This heater is; NOT; approved for use in any residential; Not For Residential Use.; property damage, serious injury or death.
- Page 4 – CAUTION; Clearance to Combustibles; Combustible Items Include:; WARNING
- Page 5 – Chart 1.1 - Clearance to Combustibles in Inches; Side; Back; Below; Mount Heater Level; FRONT VIEW; Gas Type; SIDE VIEW
- Page 6 – Dayton
- Page 7 – ayton
- Page 8 – Safety Signs and Labels; Back Panel; SAMPLE; Rating Plate
- Page 9 – Design; Fire sprinkler heads must be located at; to be used in
- Page 10 – Key; Exhauster; Perimeter mounting; Figure 2.1 - Total Area Heating Sample Layout
- Page 11 – Average
- Page 12 – that can support the total force and weight of the heater.; Heater Mounting; The heater must be level
- Page 13 – Figure 2.4 Heater Orientation; must
- Page 14 – Ventilation; consumed must be; Figure 2.6 Hot Flue Discharge
- Page 15 – Gas Supply; Chart 2.3 Manifold Pressure
- Page 17 – Electric Shock Hazard.; Electrical; Thermostat; Proper grounding and polarity are essential; Avoid Equipment Failure.
- Page 18 – Wiring Diagrams
- Page 19 – Lighting Instructions; Rotate the heater’s valve knob to the “ON”; Shutdown Instructions; Upon satisfactory completion of the electrical supply; Sequence of Operation; Upon a call for heat, voltage is
- Page 20 – Main Burner
- Page 21 – Symptom; Chart 4.1 Troubleshooting Guide
- Page 22 – Heater Assembly Components; Replacement burners are called “rayheads”
- Page 23 – Parts Listing; Chart 4.2 - Direct Spark Control Components; Gas type conversions require
- Page 24 – Additional Limited Warranty.
In locations used for the storage of
combustible materials, signs must be
posted to specify the maximum
permissible stacking height to maintain
the required clearances from the heater to the
combustibles. Signs must either be posted adjacent
to the heater thermostats or in the absence of such
thermostats, in a conspicuous location.
Keep these instructions for future reference.
Please read and save these instructions. This heater must be installed and serviced by trained gas installation and service
personnel only! Read carefully before attempting to assemble, install, operate or maintain the product described. Protect
yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury
and/or property damage! Retain these instructions for future reference.
Form 5S4078
Printed in U.S.A.
03460
1006/281/VCPVP
Dayton High-Intensity Heaters
®
Description
Dayton high-intensity heaters become highly efficient generators
of infrared radiation by heating a ceramic refractory material to
incandescence. The principal operation is to pass a gas-air mixture
through a perforated ceramic refractory, and ignite it on the refractory
surface. This causes the ceramic material to be heated to approximately
1780°F and generate large amounts of infrared radiation that may be
directed anywhere heat is desired. Infrared radiation heats people and
objects it strikes and not the intervening air. Included is a direct spark
ignition system, manifold pressure tap, porous ceramic grids, a polished
aluminum reflector and a chain set for hanging the heater. Typical
applications are loading docks, warehouses, service garages, factories,
aircraft hangars, etc.
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone.
• Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier,
call the fire department.
For Your Safety
If you smell gas:
WARNING
!
!
WARNING
!
!
®
Installation, Operation, Maintenance and Parts Manual
3E132
thru 3E134, 3E460 thru 3E462,
5VD57 thru 5VD66, 3VH34 thru 3VH37
Improper installation, adjustment,
alteration, service or maintenance can
cause property damage, injury or death.
Read and understand the installation,
operating and maintenance instructions thoroughly
before installing or servicing this equipment.
This heater must be installed and serviced by trained
gas installation and service personnel only. Failure to
comply could result in personal injury, asphyxiation,
death, fire and/or property damage.
Not for residential use!
This heater is not approved in any
residential application. This includes
(but is not limited to) the home, living
quarters, attached garages, etc. Installation in
residential indoor spaces may result in property
damage, serious injury or death.
WARNING
!
!
E
N
G
L
I
S
H
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Dayton Installation, Operation, Maintenance and Parts Manual Dayton High Intensity Heaters ® 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 E NG L I S H 1.0 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
NOTICE CAUTION ! WARNING ! ! WARNING ! ! Caution indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. WARNING ! ! Improper installation, adjustment, alteration, service or maintenance can cause property damage, serious injury or death. Read and...
CAUTION ! Dayton Installation, Operation, Maintenance and Parts Manual Dayton High Intensity Heaters ® 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 E NG L I S H 4 Clearance to Combustibles A critical safety factor to consider before installation is the clearances to combust...