Dayton 3E219D - Manual

Dayton 3E219D

Dayton 3E219D – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
Page: / 24

Table of Contents:

  • Page 2 – Dayton Operating Instructions and Parts Manual; Amperage; ELECTRICAL SPECIFICATIONS; Product Identification
  • Page 3 – General Safety Information; IMPORTANT; : Every possible circumstance
  • Page 4 – Figure 5 - Cross Section Operational View; Theory of Operation; THE FUEL SYSTEM; Fuels; • clogged fuel filter and nozzle; : Use a KEROSENE ONLY
  • Page 5 – Assembly; Ventilation; TO START HEATER; A cold heater may affect the; TO STOP HEATER
  • Page 6 – Maintenance; UPPER SHELL REMOVAL; Figure 9 - Fan Cross Section
  • Page 7 – Figure 13 - Adjusting Pump Pressure; FUEL FILTER
  • Page 8 – IGNITOR; Figure 17 - Ignitor Replacement
  • Page 9 – NOZZLE; Model
  • Page 10 – Figure 27 - Sanding Rotor; IGNITION CONTROL ASSEMBLY; Figure 28 - Replacing Fuse; PUMP ROTOR
  • Page 11 – Preventative Maintenance Schedule; How Often
  • Page 13 – Burner Head Assembly for All Models - Figure 30
  • Page 16 – Figure 33 - Replacement Parts Illustration for Model 3E218E
  • Page 17 – Replacement Parts List for Model 3E218E
  • Page 19 – Replacement Parts List for Model 3E219D
  • Page 20 – Maintenance Kits; Figure 35 - Handle and Wheel Assembly
  • Page 21 – Wiring Diagram; Figure 36 - Wiring Diagram for All Models; Ignition Control
  • Page 22 – Troubleshooting Chart; Corrective Action; Wiring Diagram, page 21; Symptom
  • Page 24 – NOT A UPC; LIMITED WARRANTY; LIMITATION OF LIABILITY.
Loading the manual

Operating Instructions & Parts Manual

Dayton Portable
Oil-Fired Heaters

®

Form 5S1792

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.

Unpacking

1. Remove all packing items supplied

with heater for shipment.

2. Remove all items from carton.

3. Check heater for any shipping

damage. If heater is damaged,
promptly inform dealer where you
bought heater.

2E510E, 2E511E, 3E218E, and 3E219D

Version B - For Reduction

G016.J

®

Figure 1 – Models 2E510E and 2E511E

Figure 2 – Models 3E218E and 3E219D

Description

Dayton Models 2E510E, 2E511E, 3E218E, and 3E219D are 40,000 to 150,000 Btu/Hr
heaters. These heaters use only Kerosene or No. 1 fuel oil for combustion and
electricity to run the motor. They are primarily intended for indoor and outdoor
temporary heating of well-ventilated buildings under construction, alteration, or
repair. They may be used in agricultural, industrial, and commercial environments.

Output

Fuel Tank Capacity

Fuel Consumption

Model

Rating Btu

Fuel

(U.S. Gallons)

(U.S. Gallons/Hr.)

Motor RPM

2E510E

40,000

Kerosene or No. 1 fuel oil

3.0

0.3

1725

2E511E

60,000

Kerosene or No. 1 fuel oil

5.0

0.44

1725

3E218E

110,000

Kerosene or No. 1 fuel oil

9.0

0.8

3450

3E219D

150,000

Kerosene or No. 1 fuel oil

13.5

1.1

3450

Hot Air

Air Pump

Shipping Weight

Heater Weight

Model

Output (CFM)

Pressure (PSI)

(Pounds)

(Pounds - without fuel)

2E510E

170

3.0

32

28

2E511E

180

3.4

33

29

3E218E

490

5.3

58

49

3E219D

550

5.4

67

56

GENERAL SPECIFICATIONS

Printed in U.S.A.
03430
0 8 9 8 / 1 5 7 / V C P V P

Specifications

ARL LOGO

G 004

®

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Dayton Operating Instructions and Parts Manual; Amperage; ELECTRICAL SPECIFICATIONS; Product Identification

Dayton Operating Instructions and Parts Manual 2 Dayton PortableOil-Fired Heaters ® 104447 2E510E, 2E511E, 3E218E, and 3E219D Amperage Model Electrical Input (during normal run) 2E510E 120 Volt/60 Hertz 2.0 2E511E 120 Volt/60 Hertz 2.0 3E218E 120 Volt/60 Hertz 3.6 3E219D 120 Volt/60 Hertz 3.6 ELECTR...

Page 3 - General Safety Information; IMPORTANT; : Every possible circumstance

3 Models 2E510E, 2E511E, 3E218E, and 3E219D Dayton Operating Instructions and Parts Manual 104447 ® General Safety Information Make certain you read and understandall warnings. Keep these instructionsfor reference. They are your guide tosafe and proper operation of thisheater. Safety information app...

Page 4 - Figure 5 - Cross Section Operational View; Theory of Operation; THE FUEL SYSTEM; Fuels; • clogged fuel filter and nozzle; : Use a KEROSENE ONLY

Dayton Operating Instructions and Parts Manual 4 Dayton PortableOil-Fired Heaters ® 104447 2E510E, 2E511E, 3E218E, and 3E219D General Safety Information(Continued) Figure 5 - Cross Section Operational View CleanHeatedAir Out Air For FuelSystem Air For Combus-tion and Heating Fuel FuelFilter Air Line...