Page 2 - PowerPanel; U S E R ’ S M A N U A L; An overview of the software capabilities is listed below:
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 1 PowerPanel ® Business Edition U S E R ’ S M A N U A L PowerPanel ® Business Edition provides power management Services. PowerPanel Business Edition consists of Agent and Slave. Agent provides a servi...
Page 3 - CONTENT; MONITOR THE BATTERY BACKUP STATUS AND VIEW THE BATTERY
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 2 CONTENT MONITOR THE BATTERY BACKUP STATUS AND VIEW THE BATTERY BACKUP INFORMATION [AGENT ONLY] ............................................................ 4 Battery Backup status monitoring ...........
Page 4 - MANAGE SCHEDULED SHUTDOWN AND RESTART SETTINGS
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 3 Configure Settings of Event Actions for the Selected Event .......................................... 21 Configure Overall Action Settings ...............................................................
Page 5 - MONITOR THE BATTERY BACKUP STATUS AND VIEW THE; B a t t e r y B a c k u p s t a t u s m o n i t o r i n g
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 4 MONITOR THE BATTERY BACKUP STATUS AND VIEW THE BATTERY BACKUP INFORMATION [AGENT ONLY] • Battery Backup status monitoring • View Battery Backup information B a t t e r y B a c k u p s t a t u s m o n...
Page 7 - V i e w B a t t e r y B a c k u p I n f o r m a t i o n; Information
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 6 • Status: Displays the present operating status of the Battery Backup. o Normal: The system status is normal. o *Fault: The system is in fault state due to an internal malfunction. o *Overheat: The t...
Page 8 - VIEW THE POWER SYSTEM INFORMATION AND; I n t r o d u c t i o n t o P o w e r S y s t e m
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 7 VIEW THE POWER SYSTEM INFORMATION AND CONFIGURE POWER SYSTEM LOCATION [SLAVE ONLY] • Introduction to Power System • View Power System information • Configure Power System address I n t r o d u c t i ...
Page 9 - due to wrong address.
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 8 The Power System Location page lets you configure the power system address and view the connection state of Power System. According to your Power System type, you may need to type Agent's address or ...
Page 10 - CONFIGURE THE BATTERY BACKUP SETTINGS AND; C o n f i g u r e t h e B a t t e r y B a c k u p; Note
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 9 CONFIGURE THE BATTERY BACKUP SETTINGS AND PERFORM DIAGNOSTICS [AGENT ONLY] • Configure the Battery Backup • Run Diagnostics on the Battery Backup C o n f i g u r e t h e B a t t e r y B a c k u p The...
Page 11 - Turn off when utility power fails for minutes: Sets how long the; utility power is restored is enabled.
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 10 o Turn off when utility power fails for minutes: Sets how long the utility power is off before turning off this outlet. The valid value is 0- 120. o Turn on when utility power restores for minutes: ...
Page 12 - Following utility frequency when it is within a tolerance: Sets; Battery
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 11 • *Restore power when the batteries have been charged to a percentage of battery capacity: Sets how much battery capacity must be present for the Battery Backup to restore power. 0% means the Batter...
Page 13 - The Battery Backup alarm is: If you enable this option, the Battery; R u n D i a g n o s t i c s o n t h e B a t t e r y B a c k u p; Battery Test
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 12 • The Battery Backup alarm is: If you enable this option, the Battery Backup alarm will sound when it switches to battery mode. Configuration options: [enabled][disabled] • *Overloaded warning when ...
Page 14 - Estimated Runtime: The estimated runtime of the batteries.
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 13 The runtime calibration synchronizes the runtime estimate with the current load and battery capacity. When a runtime calibration initiates, Calibration is initiated event occurs. A runtime calibrati...
Page 15 - CONFIGURE PROTECTED SYSTEM AND VIEW THE; C o n f i g u r e p r o t e c t e d s y s t e m i d e n t i f i c a t i o n
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 14 CONFIGURE PROTECTED SYSTEM AND VIEW THE SUMMARY • Configure protected system identification • Configure protected system connected equipment • View the system summary C o n f i g u r e p r o t e c t...
Page 16 - C o n f i g u r e p r o t e c t e d s y s t e m c o n n e c t e d e q u i p m e n t
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 15 SNMP-TRAP community key: Find this setting on Network- >Trap Notification page. Add a TrapReceiver and type Slave IP and community key to fill the fields. • SNMP-Request community key: Find thi...
Page 17 - Modify the details of the equipment in those text fields.; Click the Cancel button to cancel modifying an equipment; Select the equipment from the equipment list and click it.; Click the Cancel button to cancel removing an equipment; V i e w t h e s y s t e m s u m m a r y
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 16 2. The details of the equipment will be shown in the text field of name, location, contact, and powered by which outlet. 3. Modify the details of the equipment in those text fields. 4. Click the Mod...
Page 18 - CONFIGURE ACTION SETTINGS FOR DIFFERENT EVENTS
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 17 CONFIGURE ACTION SETTINGS FOR DIFFERENT EVENTS • Configure Settings of Event Actions for Selected Events from the Event List. • Configure Settings of Event Actions in the Event List in Quick Setting...
Page 19 - overloaded
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 18 overloaded Battery-test failure The battery-test failed to provide battery power normally. Batteries are not present Batteries are not present; the Battery Backup cannot provide battery power in thi...
Page 20 - Battery is charging
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 19 Leaves bypass mode Leaves bypass mode and switch to line mode or battery mode, battery power will be used. Battery-test is successful The Battery test was successful, battery power is normal. Batter...
Page 21 - Overview event list
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 20 Output is no longer overloaded Output is normal and no longer overloaded. Bypass is no longer overloaded Output is no longer overloaded in bypass mode. Batteries have installed The batteries have be...
Page 24 - Note: These functions may not be available on all models
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 23 • Shutdown Sequence: o Initiate a shutdown sequence for this event: If you enable this option, the Battery Backup will initiate a shutdown sequence when the event occurs. Initiate a shutdown seque...
Page 25 - openfire
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 24 o SMTP server requires validation: If you enable this option, the e- mail will be sent using the credentials you supply. If you enable this option, complete the account and password field. Please ve...
Page 27 - VIEW THE LOGS AND CONFIGURE LOGGING OPTIONS; Event Log; The display option let you to decide the event logs you want to view.; logs occurred will be displayed.; Status Record
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 26 Note: Google®, Google® Talk, and Gmail™ are either registered trademarks or trademarks of Google® Corporation in the United States and/or other countries. Windows Live ™ Messenger is either register...
Page 28 - Period: Which period you want to view the status records.; occurred will be displayed.; Log Options
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 27 • Runtime: The remaining runtime of the Battery Backup (minutes). D I S P L A Y O P T I O N The display option let you to decide the status records you want to view. • Period: Which period you want ...
Page 29 - MANAGE SCHEDULED SHUTDOWN AND RESTART; Add, Modify and Remove a schedule
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 28 MANAGE SCHEDULED SHUTDOWN AND RESTART SETTINGS [AGENT ONLY] The Schedule page lets you manage your shutdown schedules. An active (enabled) schedule will cause your system to shutdown or hibernate an...
Page 30 - Messages; Correct the shutdown time.
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 29 S H U T D OW N S C H E D U L E M E S S A G E S Messages Description The maximum duration is 30 days. Modify the Shutdown Time and Reboot Time. A schedule with duration over 30 days is not allowed. R...
Page 31 - CHANGE THE AUTHENTICATION USERNAME AND; Detail Information
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 30 CHANGE THE AUTHENTICATION USERNAME AND PASSWORD The Authentication page allows you to change the username or the password. The default username and password are "admin". You can change the u...
Page 32 - CONNECT TO THE SYSTEM FROM REMOTE COMPUTER; You need to know the administrator system host IP.
PowerPanel ® Business Edition Copyright © 2006-2007 Cyber Power Systems, Inc. All rights reserved. 31 CONNECT TO THE SYSTEM FROM REMOTE COMPUTER You can connect to the administrator system from remote computer as following steps. • You need to know the administrator system host IP. • Enter the host ...