Environment Sensor

ENVIROSENSOR

User’s Manual

Package Contents

Flat Head Screw (M3x20)

with Plastic Nylon Anchor

CAT5 RJ45 Ethernet Cable

(10 feet/3.05 m)

ENVIROSENSOR

Hook and Loop Tape

Cyber

Power

Relia

bility. Qual

ity. Va

lue.

R

User'

s M

anua

l

User’s Manual

Product Features

K01-0000207-00

Overview

The CyberPower environmental sensor (ENVIROSENSOR)

along with select SNMP/HTTP cards (RMCARDXXX) or most

Switched and Monitored PDUs enables users to monitor the

temperature and humidity of a server closet and/or datacenter

remotely. With CyberPower's PowerPanel Business Edition

software, users can establish thresholds that will automatically

notify users when an event has occurred via email, SMS and

SNMP traps. Additionally, the ENVIROSENSOR provides 4 input

dry contacts that enable users to monitor the status of connected

devices, such as door switch sensors.

Features include:

• Real time environment monitoring

• Remote management and configuration of the sensor via Web

Browsers or NMS

• Automatic events notification via email, SMS and SNMP traps

• 4 input dry contacts application interface provided

• Displays the name and location of the sensor and

connected devices

A. LED

B. Input Dry Contact 1-4

C. Common Connection

D. RJ45 Port

(connect to RMCARD/PDU)

NOTE:

Please refer to Appendix

for Input Dry Contact Application.

A

DATA

STATUS

COM

4

1

2

3

C

B

D

Technical Specification

Installation Guide

Method 1- Hook and Loop Tape

Mounting

Step 1. Clean the surface of the

area where the sensor will

be installed. Apply one side

of the hook and loop tape

to the bottom of the sensor

and the other side to the

sensor location.

Step 2. Attach the sensor on the

surface and hold for about 5

seconds to ensure cohesion.

NOTE:

Once the sensor is installed,

you will want to leave it in place to

ensure the the hook and loop tape

maintains its adhesiveness.
Step 3. To connect the sensor with

RMCARD/PDU, use the

attached RJ45 Ethernet

Cable. Plug one end into the

RJ45 Port and the other end

into the RMCARD/PDU.

NOTE:

If the distance of

RMCARD/PDU and the sensor is

longer than 10 feet/3.05 m, use a

standard RJ45 Ethernet Cable as

needed (max 50 feet/15 m).

Universal

RX/TX

Link

RMCARD203

Copyright © 2011 CyberPower Systems, Inc.

ENVIROSENSOR

Input Voltage

7V - 28V

Halt mode 72 mW/

Power Dissipation

Normal mode 110 mW

(Default 12V input)

Measurement Range and Accuracy

Temperature

32-158

with accuracy ± 1.8

/

0-70

with accuracy ± 1

Humidity

10-90 RH with accuracy ± 2%

Communication

Connection Port

RJ45 Port

Input Dry Contact

4

Physical

Dimensions (L x W x H)

2.32 x 1.77 x 1.14 inches/

59 x 45 x 29 mm

Weight

1.46 oz /41.5 g

Safety Approvals

FCC Class B, CE, C-Tick

Warranty

3 Year Limited