CyberPower CPS175SU - Manual

CyberPower CPS175SU

CyberPower CPS175SU – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual

AC Mobile Power Inverter

CPS175SU User Guide

Specifications

Troubleshooting

Fuse Replacement

Important Safety Information

Package Contents

Product Features

• AC Mobile Power Inverter
• Product Registration Card
• User Guide

1. Unplug the inverter from the DC power outlet.

2. Unscrew the contact retainer at the end of the power plug.

3. Replace the 15 amp fuse.

4. Reassemble unit by reversing the instructions above.

Input Voltage

10.5 to 15.5 volts

Output Peak Power

175 Watts

Output Continuous Power 150 Watts
Output Voltage

120 Volts

Output Frequency

60 Hz

USB Voltage

5Vdc

Output Waveform

Simulated Sine Wave

Protection Features

Low Voltage, Overheat,

Overload, Short Circuit

Problem

No AC output power Poor contact with DC power

outlet.

Automotive electrical

system requires ignition to

be on.

Car's DC power outlet fuse

is blown.

Over-heating.

Vehicle's battery voltage is

below 10.5 volts.

Vehicle's battery input

voltage is higher than 15.5

volts.

Inverter is overloaded.

Ensure the inverter is securely

plugged into vehicle's DC power

outlet. Replace the DC power outlet if

necessary.

Turn the vehicle ignition to the

"Accessory" position.

Check the vehicle fuse panel and

replace the damaged fuse.

Allow inverter to cool. Ensure that

there is adequate ventilation around

the unit and load does not exceed the

unit's Continuous Power rating (see

specifications).

Unplug the inverter and start the

vehicle to charge the battery.

Check your vehicle's user guide for

troubleshooting.

Ensure load does not exceed the

unit's Continuous Power rating (see

specifications).

Suggested Solutions

Possible Cause

Before installing and using the CyberPower CPS175SU Mobile

Power Inverter please read and follow these safety instructions:

• Moderate Temperature - Ambient air temperature should be between

32

o

F - 86

o

F (0

o

C - 30

o

C). Keep the inverter out of direct sunlight.

• Free Air Flow - Keep the inverter's ventilation slots unobstructed to

ensure air flow to the unit. Do not place any items on or over the

inverter during operation. The unit will shut down if it overheats.
Storage Tips

• Proper storage temperature range is 50

o

F - 85

o

F (10

o

C - 28

o

C)

• Store and use the inverter in a cool and dry environment.

• Avoid exposing the inverter to heating elements, direct sunlight, or

high humidity.

Operating and Storage Tips

Operating Tips

The inverter should only be operated under the following conditions:
• Dry - Do not allow water or other liquids to come into contact with

the inverter.

• Do not operate the CPS175SU near flammable materials, fumes, or

gases.

• Always use the inverter where there is adequate ventilation. Do not

obstruct the ventilation slots.

• Never immerse the unit in water.

• Proper cooling is essential when operating the inverter. Refrain

from placing the inverter near the vehicle's heat vent, or in direct

sunlight.

• Always turn the inverter off when not in use by removing it from the

DC accessory socket.

• Check the warning labels on battery chargers or adapters before

connecting them to the inverter. Do not connect battery chargers or

adapters with warnings about using with inverters.

Spring

Ring

Contact Pin

Contact Retainer

15A Fuse

12V power plug

Cyber Power S ystems (US A), Inc.

4241 12th Avenue E ast, S uite 400, S hakopee, MN 55379, U.S .A.

TE L: (952) 403-9500 FAX: (952) 403-0009 Toll-Free: (877) 297-6937

E -mail: [email protected] Web: www.cpsww.com

E ntire contents copyright

C

2010 Cyber Power S ystems, Inc.

All rights reserved. Reproduction in whole or in part without permission is

prohibited.

K01-0000157-00

Limited Warranty

Product Registration

Technical Support

Legal notices (FCC Part 15)

CyberPower warrants this CPS175SU (the "Inverter") to be free from material and

manufacturing defects for two years. If a defect results in product failure during its normal

use, CyberPower’s sole responsibility is to repair or replace (at its sole option) the Inverter.

The foregoing Limited Warranty is the consumer’s sole and exclusive remedy and excludes

any incidental or consequential damages. Some States do not allow the exclusion or

limitation of incidental and consequential damages, so certain of the above limitations or

exclusions may not apply to you (the Consumer). This limited warranty gives the Consumer

specific legal rights and the Consumer may have other rights, which vary from State to State.

To make a Limited Warranty claim:

1. Pack and ship the Inverter to CyberPower at 4241 12

th

Ave. E., Suite 400, Shakopee, MN

55379.

2. Clearly indicate on the outside of the packaging that this is a “WARRANTY RETURN”

3. Clearly include your name and address (a) on the outside packaging and (b) on a sheet

of paper enclosed in the box with the Inverter that is being returned.

4. You MUST prepay all shipping costs and you are responsible for packaging and

shipment.

CAUTION: Any changes or modifications not expressly approved by the guarantee of this

device could void the user’s authority to operate the equipment.

This Warranty is provided by:

Cyber Power Systems (USA), Inc.

4241 12th Avenue East, Suite 400, Shakopee, MN 55379, U.S.A.

Thank you for purchasing a CyberPower product. Prompt product registration entitles

coverage under the Limited Warranty and Connected Equipment Guarantee, and also allows

the opportunity to be notified of product enhancements, upgrades, and other

announcements.

Registration is quick and easy at www.cpsww.com/register

Feel free to contact our Tech Support department with installation, troubleshooting, or

general product questions.

CyberPower Technical Support

Phone: 1-877-297-6937

Email: [email protected]

Web: www.CPSww.com

Mail: 4241 12th Avenue E, Suite 400 Shakopee, MN 55379

Hours of Operation: Monday – Friday, 8:00am – 5:00pm (CST)

This equipment has been tested and found to comply with the limits for a Class B Digital

Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide

reasonable protection against harmful interference in residential installation. This

equipment generates, uses and can radiate radio frequency energy and, if not installed and

used in accordance with the instructions, may cause harmful interference to radio

communications. However, there is no guarantee that interference will not occur in a

particular installation. If this equipment does cause harmful interference to radio or

television reception, which can be determined by turning the equipment off and on, the user

is encouraged to try to correct the interference by one or more of the following measures:

(1) Reorient or relocate the receiving antenna. (2) Increase the separation between the

equipment and receiver. (3) Connect the equipment into an outlet on a circuit different from

that to which the receiver is connected. (4) Consult the dealer or an experienced radio/TV

technician for help. Any special accessories needed for compliance must be specified in

the instruction.

CAUTION: A shielded-type power cord is required in order to meet FCC emission limits and

also to prevent interference to the nearby radio and television reception. It is essential that

only the supplied power cord be used. Use only shielded cables to connect I/O devices to

this equipment.

1. 120V AC outlet

2. 12VDC Inlet

3. USB charging port

4. Power LED

5. Cooling Fan

1

4

2

3

5

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other CyberPower Models

All CyberPower Other