Table of Contents:

  • Page 5 – TABLE 1.1: SUMMARY OF HORIZONTAL VENTING OPTIONS
  • Page 6 – Termination fittings are never counted.; CAUTION
  • Page 8 – Crown
  • Page 11 – FIGURE 1.9c: POSITIONING VENT TERMINAL UNDER OVERHANGS
  • Page 12 – FIGURE 1.10: SNORKEL TERMINAL CONFIGURATION
  • Page 13 – TABLE 1.12: SUMMARY OF VERTICAL VENTING OPTIONS
  • Page 14 – FIGURE 1.13: WALL PENETRATION CLEARANCES FOR PVC VENT PIPE
  • Page 16 – WARNING
  • Page 22 – C. Condensate Trap and Drain Line; Insert the hose
  • Page 24 – D. Removing an Existing Boiler From a Common Chimney; section does not apply to the installation of a BWC boiler.; NEVER COMMON VENT A BWC BOILER WITH OTHER APPLIANCES.
  • Page 25 – IMPORTANT; installation of side-wall vented gas appliances as follows:
  • Page 26 – Manufacturer of Hydronic Heating Products
Loading the manual

BWC Series

Direct Vent Condensing Boilers

InStallatIon SUPPlEMEnt FoR BoIlERS

VEntED WItH CPVC/PVC PIPE

These instructions must be affixed on or adjacent to the boiler.

Models:

BWC070

BWC090

BWC120

BWC151

BWC150

BWC225

WaRnIng

: Improper installation, adjustment, alteration,

service or maintenance can cause property damage, injury,

or loss of life. For assistance or additional information, con-

sult a qualified installer, service agency or the gas supplier.

This boiler requires a special venting system. Read these

instructions carefully before installing.

D

E S I G N E D T O

L

E A D

Manufacturer of Hydronic Heating Products

P.O. Box 14818 3633 I. Street

Philadelphia, PA 19134

Tel: (215) 535-8900 • Fax: (215) 535-9736 • www.crownboiler.com

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 5 - TABLE 1.1: SUMMARY OF HORIZONTAL VENTING OPTIONS

2 3 TABLE 1.1: SUMMARY OF HORIZONTAL VENTING OPTIONS VENT OPTION # 1 2 3 4 CLASSIFICATION USED IN THIS MANUAL HORIZONTAL TWIN PIPE HORIZONTAL TWIN PIPE HORIZONTAL TWIN PIPE HORIZONTAL TWIN PIPE ILLUSTRATED IN FIGURE 1.2 1.3 1.4 1.4 VENT PIPE PENETRATION THROUGH STRUCTURE WALL WALL WALL WALL AIR INTA...

Page 6 - Termination fittings are never counted.; CAUTION

4 5 Approved vent components and materials - The adaptor kits listed in Table 1.5 are required to connect the venting 2. to the boiler. Starting at the boiler, the first 30 inches of the vent system, and the first elbow, must be CPVC . In addition, use only pipe that meets the following standards: C...

Page 8 - Crown

6 7 Horizontal Vent and Air Intake Terminal Location 6. - Observe the following limitations on the vent terminal location (also see Figure 1.9). When locating a concentric terminal, observe the limitations outlined below for “vent terminals”. Vent terminal must be at least 1 foot from any door, wind...

Other Crown Models

All Crown Other