Crown 29PT9467S - Manual
Crown 29PT9467S – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Commercial, Forced Draft; Apartments and other; Commercial Hot Water
- Page 3 – Standard Equipment; All Boilers; Steam Trim; Gas Boilers; Optional Equipment
- Page 4 – Series 24 Dimensions; Tankless Heater
- Page 5 – Burner Mounting Plates and Adapter Plates; Control Tappings; Impact of System Piping; RTC Return Temperature Control; Commercial Hot Water or Steam Boiler
- Page 6 – Series 24 Minimum Piping Recommendations – Water Boiler; Recommendation 1; Recommendation 2
- Page 7 – Recommendation 3; Series 24 Minimum Piping Recommendations – Steam Boiler
- Page 8 – Series 24 Specifications; Since 1949, homeowners have depended on us; Beckett Gas Burners
■
Cast iron sectional heat exchanger
and push nipples
■
Vertical flue design
■
Easily assembled with short individual draw rods
■
Optional tankless heater for domestic hot water
■
Top or rear vent connections
■
Side clean out plates
■
Optional Return Temperature Control (RTC)
■
Sizes from 342,000 to 1,852,000 BTU/hr output
Heat exchanger constructed
and tested in accordance with
ASME Section IV standard.
Commercial, Forced Draft
Hot Water or Steam Boiler
Commercial, Forced Draft
Hot Water or Steam Boiler
For Businesses, Institutions,
Apartments and other
commercial buildings
For Businesses, Institutions,
Apartments and other
commercial buildings
Commercial Hot Water
or Steam Boiler
Commercial Hot Water
or Steam Boiler
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
1. Optimum for large installations – Available in ten sizes from 342,000 to 1,852,000 BTU/hr output. 2. Gas, oil or combination gas/oil fired – Customer’s preference in the choice of fuels for economy and availability may be an important part of the purchase decision. 3. Hot water or steam – The Seri...
Standard Equipment All Boilers – Sections unassembled, flush insulated jacket, burner mounting plate, burner adapter plate, rear flue damper (top outlet optional), flue canopy, rear observation port cover, target wall (V-903A), and miscellaneous plugs, bushings and fittings. Steam Trim – 15 PSI safety v...
Series 24 Dimensions (in inches) SAFETY/RELIEF VALVE ‘F’ O.D. COLLAR (STD. REAR OUTLET) 3 ‘C’ ‘A’ 4 ‘D’ INSULATED JACKET COMBINATION LABEL RATING LABEL � HIGH PRESSURE LIMIT CONTROL/MR � HIGH PRESSURE LIMIT CONTROL/MR NWL 57 MM#67 LWCO LOWEST PERMISSIBLE WATER LEVEL PLATE (STEAM ONLY) FLOOR FRONT VI...