Page 2 - Commercial, Forced Draft; Apartments and other; Commercial Hot Water
1. Optimum for large installations – Available in ten sizes from 342,000 to 1,852,000 BTU/hr output. 2. Gas, oil or combination gas/oil fired – Customer’s preference in the choice of fuels for economy and availability may be an important part of the purchase decision. 3. Hot water or steam – The Seri...
Page 3 - Standard Equipment; All Boilers; Steam Trim; Gas Boilers; Optional Equipment
Standard Equipment All Boilers – Sections unassembled, flush insulated jacket, burner mounting plate, burner adapter plate, rear flue damper (top outlet optional), flue canopy, rear observation port cover, target wall (V-903A), and miscellaneous plugs, bushings and fittings. Steam Trim – 15 PSI safety v...
Page 4 - Series 24 Dimensions; Tankless Heater
Series 24 Dimensions (in inches) SAFETY/RELIEF VALVE ‘F’ O.D. COLLAR (STD. REAR OUTLET) 3 ‘C’ ‘A’ 4 ‘D’ INSULATED JACKET COMBINATION LABEL RATING LABEL � HIGH PRESSURE LIMIT CONTROL/MR � HIGH PRESSURE LIMIT CONTROL/MR NWL 57 MM#67 LWCO LOWEST PERMISSIBLE WATER LEVEL PLATE (STEAM ONLY) FLOOR FRONT VI...
Page 5 - Burner Mounting Plates and Adapter Plates; Control Tappings; Impact of System Piping; RTC Return Temperature Control; Commercial Hot Water or Steam Boiler
Burner Mounting Plates and Adapter Plates FRONT VIEW SIDE VIEWS 4” STANDARD IDENTIFICATION NUMBER ‘A’ DIA HOLE ‘B’ DIA BOLT CIRCLE ‘C’ (REF) 4 8 8” EXTENDED CAST IRON BURNER MOUNTING PLATES STANDARD BURNER ADAPTER PLATE I.D. ‘A’ ‘B’ ‘C’ BOILER MODEL PART NO. NO. DIA. DIA. REF. 24-03 THRU 24-05 33040...
Page 6 - Series 24 Minimum Piping Recommendations – Water Boiler; Recommendation 1; Recommendation 2
Series 24 Minimum Piping Recommendations – Water Boiler Recommendation 1 is used when the load is constant and not varied due to mixing or multiple zones. Use when: ■ system return water is not less than 135° F for prolonged periods of time ■ system flow does not impact flow through the boiler DRAIN V...
Page 7 - Recommendation 3; Series 24 Minimum Piping Recommendations – Steam Boiler
Recommendation 3 is used when the return water temperature goes below 135°F for prolonged periods of time. This is also primary-secondary piping, but includes the addition of a 3-way valve, return water sensor and boiler-mounted RTC Return Temperature Control. RETURN PIPING SIZE (IN) SUPPLY RETURN R...
Page 8 - Series 24 Specifications; Since 1949, homeowners have depended on us; Beckett Gas Burners
Series 24 Specifications BURNER HEATING WATER BOILER WEIGHT NET I=B=R RATING INPUT SURFACE NET PRESSURE CONTENT w/ WATER GROSS (SQ. FT.) FIREBOX IN (GAL.) (LBS.) VENT BOILER HORSE- OUTPUT SQ. FT. MBH MBH OIL GAS VOLUME FIREBOX DIA. MODEL POWER (MBH) STEAM STEAM WATER (GPH) (MBH) STEAM WATER (CU. FT.)...