Crown 16-325 500506 - Manual

Crown 16-325 500506

Crown 16-325 500506 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
Page: / 48

Table of Contents:

  • Page 3 – Table of Contents; Knockdown Boiler Assembly Instructions 6; I Product Description
  • Page 4 – II Specifications
  • Page 5 – III Before Installing; National Fuel Gas Code; IV Locating the Boiler; WARNING
  • Page 6 – Figure 2: Minimum Clearances to Combustibles; Boiler Model
  • Page 8 – V Knockdown Boiler Assembly Instructions; punctures due to mishandling.; DO NOT EXCEED THE 50 PSI; pressure gauge and related piping used in the leak test.
  • Page 9 – ) Slide or walk the assembly into its permanent position.; DO NOT DROP; near boiler supply piping.; Figure 4: Boiler Shipping Arrangement With Tapping Locations; Table 4: Tapping Purpose Chart
  • Page 11 – instructions on leak testing the gas piping.; E. Ignition Control & Gas Valve Installation; the other half of the union located on the gas manifold. See Figure 8.
  • Page 12 – Figure 6: Jacket Assembly
  • Page 14 – shown in Figure 4. Control and trim components are as follows:; Figure 9: Temperature-Pressure Gauge Installation
  • Page 15 – VI Air For Combustion and Ventilation; Warning; to assure proper combustion.
  • Page 16 – Figure 10: Boiler Installed In Confined Space, All Air From Inside
  • Page 20 – without; chimney sealed tight.; Do not
  • Page 21 – metal screws and support as required.; Figure 17: Vent Damper Installation Details
  • Page 22 – Removing An Existing Boiler From A Common Chimney; appliance will operate continuously.
  • Page 23 – VIII System Piping; A. Standard Heating System Piping; Installation of Residential Hydronic Systems; CAUTION
  • Page 24 – to drain and refill the entire system.; B. Piping for Special Situations; Radiant systems that employ tubing without an oxygen barrier.
  • Page 27 – IX Gas Piping; Figure 20: Gas Main Piping And Branch Connections To Boiler
  • Page 28 – X Control System Wiring; boiler. Do not install these devices in the 24 volt factory wiring.; Sequence of Operation – Vent Damper (If Used); ) The vent damper is continuously powered at terminal 1.; DANGER
  • Page 30 – Figure 21: Series 16 Standard Boiler Wiring
  • Page 32 – Safety Control Operation
  • Page 33 – XI Start-up and Checkout; ) Make sure that the boiler is filled with water.
  • Page 35 – Figure 25: Gas Valve Detail - Robertshaw 7000DERHC; Repair any leaks found at once.
  • Page 36 – LIGHTING INSTRUCTIONS FOR BASE MODULES EQUIPPED WITH
  • Page 37 – XII Service and Maintenance; The following routine maintenance should be performed:; flow of combustion and ventilation air.
  • Page 39 – XIII PARTS
  • Page 40 – Figur
  • Page 45 – JACKET PANEL CARTON
  • Page 47 – OPTIONAL AUTOMATIC VENT DAMPER KIT
  • Page 48 – Manufacturer of Hydronic Heating Products
Loading the manual

1

D

E

S

I

G

N

E

D

T

O

L

E

A

D

Tel: (215) 535-8900 • Fax: (215) 535-9736 • www.crownboiler.com

Manufacturer of Hydronic Heating Products

P.O. Box 14818 3633 I. Street

Philadelphia, PA 19134

Series 16

Gas-Fired Natural Draft Water Boilers

INSTALLATION AND OPERATING INSTRUCTIONS

These instructions must be affixed on or adjacent to the boiler.

WARNING

: Improper installation,

adjustment, alteration, service or
maintenance can cause property
damage, injury, or loss of life. For
assistance or additional information,
consult a qualified installer, service
agency or the gas supplier. Read
these instructions carefully before
installing.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Table of Contents; Knockdown Boiler Assembly Instructions 6; I Product Description

3 Table of Contents I. Product Description . . . . . . . . . . . . . . . . . . . 1 II. Specifications . . . . . . . . . . . . . . . . . . . . . . . . 2 III. Before Installing . . . . . . . . . . . . . . . . . . . . . . 3 IV. Locating the Boiler . . . . . . . . . . . . . . . . . . . . 3 V. Knockdown ...

Page 4 - II Specifications
Page 5 - III Before Installing; National Fuel Gas Code; IV Locating the Boiler; WARNING

5 III Before Installing 1) Safe, reliable operation of this boiler depends upon installation by a professional heating contractor in strict accordance with this manual and the requirements of the authority having jurisdiction. • In the absence of an authority having jurisdiction, installation must b...

Other Crown Models

All Crown Other