Crestron GLS-ODT-W-1200 - Manual

Crestron GLS-ODT-W-1200

Crestron GLS-ODT-W-1200 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
Page: / 2
Loading the manual

FCC Compliance Statement:

This device complies with part 15 and part 18 of the FCC rules. Operation is subject to the following
two conditions: (1) This device must not cause harmful interference, and (2) This device must accept
any interference received, including interference that may cause undesired operation.

Further Inquiries

If you cannot locate specific information or have questions after reviewing this guide, please take
advantage of Crestron's award winning customer service team by calling Crestron at 1-888-CRESTRON
[1-888-273-7876].
You can also log onto the online help section of the Crestron website (www.crestron.com/onlinehelp) to
ask questions about Crestron products. First-time users will need to establish a user account to fully
benefit from all available features.

Future Updates

As Crestron improves functions, adds new features and extends the capabilities of the GLS-ODT-W-1200
units, additional information may be made available as manual updates. These updates are solely
electronic and serve as intermediary supplements prior to the release of a complete technical
documentation revision.
Check the Crestron website periodically for manual update availability and its relevance. Updates are
identified as an “Addendum” in the Download column.

INSTALLATION INSTRUCTIONS

These instructions include three typical installation options (A, B and C). Choose one that
best suits your needs. Other methods may be possible but they are not described here.

Parts Supplied

Sensor (1)
#8-32 x 1/2” screw (2)
#8-32 x 1-1/2” screw (2)
#8x32 Washer and Nut (2)

Tools/Equipment Required (not supplied)

Slotted/Phillips Screwdriver

Electrical Tape

Pliers Pencil
Diagonal Cutters

Model/Features

The Occupancy Sensor is a low-voltage infrared and ultrasonic sensor that works with the

GLS-SIM (or other compatible interface)

to automatically control lighting. The exact behavior

of the sensor can be configured via software, but the sensor is typically used to turn lights on
when a room or area is occupied, and to shut them off when the room or area is vacated.
The sensor continually analyzes and adjusts to changing conditions. The sensor uses the
latest microprocessor-based technology which permits it to continually adjust and optimize its
performance. The combination of ultrasonic (doppler shift) motion detection, which gives
maximum sensitivity, and infrared motion detection, which gives higher false triggering
immunity, yields a sensor with excellent performance.

DESCRIPTION

To be installed and/or used in accordance with appropriate electrical codes and regulations.

• If you are unsure about any part of these instructions, consult a qualified electrician.
• Sensors must be mounted on a vibration free surface.
• All sensors must be mounted at least 6 feet away from air vents.
• Do not mount sensors closer than 10 feet from each other.
• Do not touch the inner surface of the lens. Clean outer surface with a damp cloth only.

WARNINGS, CAUTIONS & NOTES

When wiring the Cresnet

®

network, consider the following:

Use Crestron Certified Wire.

• Use Crestron power supplies for Crestron equipment.

Provide sufficient power to the system.

NETWORK WIRING

CAUTION:

Insufficient power can lead to unpredictable results or damage to the

equipment. Please use the Crestron Power Calculator to help calculate how much power
is needed for the system. (www.crestron.com/calculators).

WARNING:

To avoid fire, shock, or death; turn off power at circuit breaker or fuse and

test that power is off before wiring!

NOTES:

Observe the following points regarding sensor installation.

PREPARING AND CONNECTING WIRES

Strip the ends of the wires approximately 1/2”. Use care to avoid nicking the conductors. Twist together

the ends of the wires that share a connection and tin the twisted connection. Apply solder only to the

ends of the twisted wires. Avoid tinning too far up the wires or the end becomes brittle.

Crestron

GLS-ODT-W-1200

DUAL-TECHNOLOGY WALL MOUNTED
OCCUPANCY SENSOR
Operations & Installation Guide

Coverage

1200 sq. ft

Suggested

Mounting Location

Mount in corner/
over doorway

Model No.

GLS-ODT-W-1200

Description

1-Way Dual-Technology

Operating

Frequency

32KHz

Current

Consumption

30mA

MOUNTING LOCATION DIAGRAM

Mounting to Drop Ceiling Using

Screws, Nuts, and Washers

OPTION A. Wallboard or Drop Ceiling Installation Using Screws

NOTE:

You may use the mounting screws, nuts and washers included, or screws in

combination with commercially available wall anchors.

1. Select the location for mounting of the sensor for your application. (Refer to Mounting

Location Diagram).

2. Make a hole in the wallboard or ceiling tile large enough to pass the wire connections

and wire nuts through (approximately 1" diameter).

3. Drill holes for monting screws using mounting bracket as a guide.
4.

Install the mounting bracket of the wall sensor to the wallboard or ceiling using the

included screws, nuts and washers.

5. P

ass wires through the base cover/neck assembly. (

Refer to the suggested mounting

option illustrations below

.)

6. Connect low voltage wires from the GLS-SIM or other Crestron

®

device as shown in the

wiring diagram. Twist strands of each lead tightly and, with circuit conductors, push firmly
into appropriate wire connector. Screw connectors on clockwise making sure that no
bare conductor shows below the wire connectors. Secure each connector with electrical
tape.

7. Push wire connections through the center hole of the back cover and into the wall or

ceiling.

8.

Snap neck and base cover onto mounting bracket in the desired orientation.

9.

Push wires through the hole and begin to fasten the plastic nut around the

back of the

sensor body. Move the sensor body to the desired orientation and then continue to
tighten the nut around the sensor body.

10. Restore power at the circuit breaker or fuse. INSTALLATION IS COMPLETE.

OPTION B. Wallboard or Drop Ceiling Installation Using Back Box

OPTION C. Surface Mount Raceway Installation

Mounting to Octagon Back Box Installed Flush to Drop Ceiling

TYPICAL APPLICATION DIAGRAMS

Up to Three

in

Parallel

The following illustration provides a typical application example.

1. Select the location for mounting of the sensor for your application.

(Refer to Mounting Location Diagram).

2. Refer to the suggested mounting option illustrations below.

Mounting to Round Fixture with Raceway for Wallboard Ceiling Installation

GLS-ODT-W-1200

GLS-SIM

(Optional)

Mounting to Wallboard Using Screws

Low-Voltage

Wires

Drop Ceiling

Sensor

Base Cover

Screw, Nut and
Washer
(2 places)

Plastic Nut

Mounting

Base

Mounting Screws

(2 places)

Mounting Base

(top view)

Low-Voltage

Wires

Wallboard

Base Cover/

Neck Assembly

Sensor

Plastic Nut

Mounting Screws
(2 places)

4" Octagon

Raised Cover

4" Octagon

Raised Cover

Mounting Base

Octagon Box
4" 1 1/2" deep

Wallboard Ceiling

Mounting to Octagon Back Box Installed Flush to Wallboard

Octagon Box
4" 1 1/2" deep

Wallboard

Mounting Screws
(2 places)

Wallboard

Mounting Screws for Wire Mold Fixture

(2 places)

Wire Mold

Round Fixture

Wire Mold

Back Cover

Wire Mold

Raceway

GLS-ODT-W-1200

GLS-ODT-W-1200

GLS-SIM

(Optional)

GLS-SIM

(Optional)

GLS-SIM
(Optional)

GLS-SIM

Cresnet

®

DIN-IO8

Cresnet

®

Crestron

2-Series Control

Processor or

CLS-C6

Crestron

2-Series Control

Processor

Sensor

#1

24 1 2 G

optional

Sensor

#2

(

)

Red

Black

Black

Red

Red

*

Blue

*

Sensor

#1

Black

Red

Blue*

Connecting Sensors to the GLS-SIM

Connecting Sensors to the DIN-IO8 or Equivalent**

All wires from sensor to GLS-SIM

must be 24 AWG, minimum.

* To incorporate the internal photocell , connect
gray wire to GLS -SIM and cap off blue wire
from sensor.

Gray*

(cap off)

Gray*

(cap off)

–SENSOR–

––– NET–––

24 Y Z G

Use CRESNET-P or

CRESNET-NP wire only

GLS-SIM

Sensor

#1

optional

Sensor

#3

(

)

To Control

System

G 1 2 3 4

––– NET

G 1 2 3 4

24 Y Z G

24 Y Z G

–––

To Control

System

–––

–––

I/O

DIN-IO8

NOTE

: The same Crestron power supply MUST be used to

power both the sensors and the interface device (e.g., DIN-IO8).
Otherwise, there is a risk of damage to the interface device.

*To incorporate the internal photocell, connect the gray wire to
the DIN-IO8 (or other interface device) and cap off the blue wire
from the sensor.

WIRING DIAGRAMS

Black

Blue

Blue*

**The following Crestron devices may be used to
integrate the sensors into a Cresnet system by
following the schematic shown here:

DIN-IO8 DIN-AP2 PAC2

PRO2

AV2 CP2E MP2E CNXIO16

Any Crestron product with Versiports

Use CRESNET-P or

CRESNET-NP wire only

Crestron Electronics, Inc.

Operations &

Installation Guide-DOC. 6771A

15 Volvo Drive Rockleigh, NJ 07647

(2023018)

Tel: 888.CRESTRON

12.08

Fax: 201.767.7576

Specifications subject to

www.crestron.com

change without notice.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Crestron Models

All Crestron Other