Cooper Lighting MPWC - Manual

Cooper Lighting MPWC

Cooper Lighting MPWC – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4

Table of Contents:

  • Page 2 – Specifications and Dimensions subject to change without notice.; MPWC; MBC
  • Page 3 – ORDERING INFORMATION
  • Page 4 – PHOTOMETRICS; C a n d l e p o w e r D i s t r i b u t i o n; Zone; C o e f f i c i e n t o f U t i l i z a t i o n
Loading the manual

Catalog #

Project

Comments

Prepared by

Type

Date

SPECIFICATION FEATURES

04/15/2007 12:56:42 PM

Consult your representative for additional options and finishes.

Specifications and Dimensions subject to change without notice.

ADC041675

LAMP CONFIGURATIONS

MOUNTING DIMENSIONS

DESCRIPTION

Fail-Safe's MPWC series combines a multi-function, wall mounted fixture
with contemporary styling. Through innovative features, the MPWC
accommodates multiple applications throughout the healthcare
environment. One fixture supplies the patient room with task lighting,
offering practical solutions to the patient and medical staff for everyday
tasks. The MPWC is separated into two compartments: up light for general
ambient room lighting and down light for reading/direct task lighting to
accommodate the needs of the patient or healthcare professional. The
fixture is UL listed.

Application

The MPWC is designed for use in
healthcare environments,
specifically for use in patient
rooms over beds to facilitate all of
the tasks required by the patient
and medical staff. The MPWC's
aesthetics make it ideal for other
applications such as over vanities,
rest rooms, and hallways.

A ... Lens

Up light: .125" thick, prismatic K12
pattern, acrylic lens is standard
(prisms on the inside for ease of
cleaning). Down light: .125" thick,
prismatic K12 pattern, acrylic lens
is standard (prisms inside).

B ... Fasteners

Nickel-plated thumbscrews are
standard (requires no tools to
remove lens assembly).

C ... Construction

Outer housing is 18 gauge,
die-formed, cold rolled steel with
seam-welded ends. Back pan
housing is 20 gauge, die formed
cold rolled steel. Power tray and
reflector are 20 gauge cold rolled
steel.

D ... Lamps

T8 Linear Fluorescent
T5 HO Linear Fluorescent

E ... Ballast Options

T8 Electronic Instant Start
T5 Electronic Programmed Start
T8 Magnetic-HPF

F ... Finish

High gloss white polyester powder
coat finish is standard on exterior
housing. A multistage cleaning and
painting process is utilized. Interior
reflector is high reflectance white,
minimum reflectance 92%. Custom
colors are available.

Labels

UL/cUL Listed for Damp Locations

MPWC

34W - 216W

Fluorescent

CONTEMPORARY

HEALTHCARE

WALL MOUNTED

LUMINAIRE

C

D

E

B

A

6”

[153mm]

6 1/2”

[165mm]

1 7/8”

[47MM]

1 7/8”

[47MM]

1 7/8”

[47MM]

1 7/8”

[47MM]

24 3/8”[620mm]

36 3/8”[925mm]

22”[559mm]

34”[864]

20”[508mm]

8”[203mm]

6 1/16”

[154mm]

6 1/16”

[154mm]

6 1/16”

[154mm]

3/16 X 11/16”

[4.8 X 17.5mm]

Keyhole Mtg. Holes

3/16 X 11/16”

[4.8 X 17.5mm]

Keyhole Mtg. Holes

3/16 X 11/16”

[4.8 X 17.5mm]

Keyhole Mtg. Holes

2 1/4”

[57mm] Dia.

Access Hole

2 1/4”

[57mm] Dia.

Access Hole

2 1/4”

[57mm] Dia.

Access Hole

48 3/8”[1229mm]

46”[1168mm]

32”[813mm]

16”[406mm]

E N E R G Y D ATA

Input Watts:

T5HO Fluorescent Lamps

Electr onic Ballasts*

(2) 24W T5 HO Lamps: 54W

(3) 24W T5 HO Lamps: 79W

(4) 24W T5 HO Lamps: 104W

(2) 39W T5 HO Lamps: 80W

(3) 39W T5 HO Lamps: 127W

(4) 39W T5 HO Lamps: 174W

(2) 54W T5 HO Lamps: 124W

(3) 54W T5 HO Lamps: 182W

(4) 54W T5 HO Lamps: 240W

*Energy Data calculated using

2 ballasts per each lamp

configuration. (Programmed start,

normal light output, average ballast

factor 0.95 to 1.1)

T8 Fluorescent Lamps

Electr onic Ballasts*

(2) 17W T8 Lamps: 40W

(3) 17W T8 Lamps: 54W

(4) 17W T8 Lamps: 68W

(2) 25W T8 Lamps: 54W

(3) 25W T8 Lamps: 74W

(4) 25W T8 Lamps: 94W

(2) 32W T8 Lamps: 64W

(3) 32W T8 Lamps: 90W

(4) 32W T8 Lamps: 116W

*Energy Data calculated using

2 ballasts per each lamp

configuration. (Instant start, normal

light output, average ballast factor

0.9 to 1.0)

F A I L - S A F E

®

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Specifications and Dimensions subject to change without notice.; MPWC; MBC

Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 04/15/2007 12:56:42 PM Specifications and Dimensions subject to change without notice. ADC041675 MPWC F e a t u r e s , C a t a l o g L o g i c a n d O p t i o n s B a l l a s t...

Page 3 - ORDERING INFORMATION

Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 04/15/2007 12:56:42 PM Specifications and Dimensions subject to change without notice. ADC041675 ORDERING INFORMATION LNL = LED Night Light (50,000 hrs.) provided by Cooper

Page 4 - PHOTOMETRICS; C a n d l e p o w e r D i s t r i b u t i o n; Zone; C o e f f i c i e n t o f U t i l i z a t i o n

Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 04/15/2007 12:56:42 PM Specifications and Dimensions subject to change without notice. ADC041675 PHOTOMETRICS C a n d l e p o w e r D i s t r i b u t i o n Z o n a l L u m e n S...

Other Cooper Lighting Models

All Cooper Lighting Other