FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN SERIOUS INJURY OR DEATH

NOTE

: Use minimum 90°C supply wire rating for connections.

WALL MOUNT ARM ACCESSORY (ENVOY PARKING LUMINAIRE) INSTALLATION:

(Figure 1)

1.

Affix wall mount arm on the wall with (4) four bolts (provided by others).

Note

: Use RTV or liquid sealant to seal back of arm if necessary.

2.

Remove quick mount plate from the luminaire and install it on the wall mount arm with provided #8-32 screws. Quick mount plate will only mount in one
direction. Align (2) bosses on arm with (2) slots on plate.

3.

To install luminaire, secure hanging hook into the front hooks of quick mount plate.

4.

Make wiring connections while luminaire is suspended on hanging hook.

5.

Lift up luminaire onto the (4) four hooks of quick mount plate while guiding the wires through center access hole.

6.

Pull luminaire forward for engagement. When it reaches the full-engaged position, a “CLICK” can be heard.

CAUTION

: If full engagement is not reached, it is not yet rigidly installed.

7.

Install arm cover with provided #10-24 flat head screws.

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation,
operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.

NOTE:

Specifications and dimensions subject to change without notice.

EPL/WM Envoy

Wall Mount Arm

Sheet 1 of 1

4/7/08

IMI-695B

INSTALLATION INSTRUCTIONS

IMPORTANT

: READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN FOR FUTURE REFERENCE

GENERAL

: Upon receipt of luminaire thoroughly inspect for any freight

damage, which should be brought to the attention of the delivery
carrier. Compare the catalog description listed on the packing slip
with the luminaire label on the housing to assure you have received the
correct merchandise.

SAFETY

: This luminaire must be wired in accordance with the national

electrical code and applicable codes and ordinance. Proper grounding
is required to insure personal safety. Carefully observe grounding
procedure. All work should be done by a qualified electrician.

WARNING

: Make certain power is OFF before starting installation or

attempting any maintenance.

WARNING

: Risk of Electric Shock. Disconnect power at fuse or circuit

breaker before installing or servicing.

WARNING

: Risk of Burn. Disconnect power and allow luminaire to cool

before changing lamp or handling luminaire.

WARNING

: This luminaire is for use with downlight application only.

WARNING

:

RISK OF FIRE!

DO NOT mount on or near combustible

materials.

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801

ADH080773

Figure 1

ARM BOSSES

FRONT HOOKS

WALL MOUNT ARM

MIN. 1/4” BOLT
(BY OTHERS)

ARM COVER

QUICK MOUNT
PLATE

#8-32 SCREW

LUMIINAIRE
HANGING HOOK

#10-24 FLAT HEAD
SCREWS

CENTER ACCESS HOLE

4.75

[120.6]

2.38

[60.5]

MOUNTING HOLE

PATTERN