3.

Disconnect PRIMARY QUICK-DISCONNECT by grabbing sides
and pulling away from fixture. (Fig. 3)

NOTE

: Fusing and the cube starter are accessible from

the bottom, exposed side of the POWER TRAY. They
may be serviced without opening the POWER TRAY.

4.

Hold POWER TRAY HANDLE and press POWER TRAY
LATCH away from the power tray. Hinge power tray up
and lift from fixture.
(Fig. 4)

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please
contact your nearest representative.

Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269

IMI-572 AVU040062

Ascent/Strut Fixtures

Sheet 1 of 5

4/26/04 IMI-572

INSTALLATION INSTRUCTIONS

IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE.

General:

Upon receipt of fixture thoroughly inspect for any

freight damage, which should be brought to the attention of
the delivery carrier. Compare the catalog description listed
on the packing slip with the fixture label on the housing to
assure you have received the correct merchandise.

Safety:

This fixture must be wired in accordance with

the national electrical code and applicable local codes
and ordinance. Proper grounding is required to insure
personal safety. Carefully observe grounding procedure.
All work should be done by an electrician.

TM

WARNING:

Risk of Electric Shock. Disconnect power at fuse or circuit breaker panel or
fuse box before installing or servicing.

WARNING:

Risk of Personal Injury. Fixture may become damaged and/or unstable if not
installed properly. Tighten all fixture components to their recommended torque
values.

1.

Open door by depressing LATCH BUTTONS into door and
lifting. (Fig. 1)

2.

Remove DOOR while it is at a 20° - 30° angle to the housing.
This will allow the door to slide over and forward from the
hinges. (Fig. 2)

Fig. 1

Fig. 2

Fig. 3

LATCH
BUTTONS

PRIMARY
QUICK
DISCONNECT

FUSES

STARTER

Fig. 4

POWER TRAY
HANDLE

POWER TRAY
LATCH

DOOR

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.