FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN SERIOUS INJURY OR
DEATH

NOTE

: Use minimum 90°C supply wire rating for connections in J-box.

Fixture Orientation Guideline:

Proper orientation of luminaire may vary based upon design requirements
specified per given application. Labels are supplied on top of fixture and
mounting plate for reference to proper fixture alignment. Align quick mount
plate in correct direction by referencing number of fixtures required (double or
single row luminaire installation) to direction of arrows. Direction of arrow(s)
should be in line with direction of traffic.

LUMINAIRE INSTALLATION:
1.

Install quick mount plate on a 4” junction box as shown in (Figure 1).
Note the required position of plate to ensure correct light beam
orientation from fixture. See guidelines above or labels on top of fixture
housing and mounting plate if applicable.

2.

Secure hanging hook into the rear hooks of quick mount plate
(Figure 2 & 3).

3.

Make wiring connection while luminaire is being suspended from hanging
hook.

4.

Push excess wires and connectors up into the junction box through center
access hole.

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation,
operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.

NOTE:

Specifications and dimensions subject to change without notice.

EPL Envoy

Parking Luminaire

Sheet 1 of 5

8/20/08

IMI-694

INSTALLATION INSTRUCTIONS

IMPORTANT

: READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN FOR FUTURE REFERENCE

GENERAL

: Upon receipt of luminaire thoroughly inspect for any freight

damage, which should be brought to the attention of the delivery
carrier. Compare the catalog description listed on the packing slip
with the luminaire label on the housing to assure you have received the
correct merchandise.

SAFETY

: This luminaire must be wired in accordance with the national

electrical code and applicable codes and ordinances. Proper grounding
is required to insure personal safety. Carefully observe grounding
procedure. All work should be done by a qualified electrician.

WARNING

: Make certain power is OFF before starting installation or

attempting any maintenance.

WARNING

: Risk of Electric Shock. Disconnect power at fuse or circuit

breaker before installing or servicing.

WARNING

: Risk of Burn. Disconnect power and allow luminaire to cool

before changing lamp or handling luminaire.

WARNING

: This luminaire is for use with downlight applications only.

WARNING

:

RISK OF FIRE!

DO NOT mount on or near combustible

materials.

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801

ADH080771

Figure 3

Figure 1

Figure 2

CENTER ACCESS
HOLE

#8-32 SCREW

QUICK MOUNT
PLATE

J-BOX

J-BOX

HANGING
HOOK

LUMINAIRE

LIFT UP

THEN PUSH
LUMINAIRE
BACK

FRONT HOOKS

LUMINAIRE
HANGING HOOK

REAR HOOKS

QUICK MOUNT