COOPER LIGHTING - LUMARK

®

INDUSTRIAL

527

C O O P E R L I G H T I N G

D I M E N S I O N S

• Easy slide-on die-cast

aluminum mounting box
with tapped opening for
3/4" conduit

• Durable heavy-duty

die-cast aluminum
housing for lasting
performance in the
harshest environments.
Integrally hinged for
ease of maintenance with
optional toolless entry.
Finished in a standard
white polyester powder
paint

• High power factor ballast

with class H insulation.
ECON

TM

electronic

ballast technology
delivers longer lamp life
and improved lumen
output while maintaining
a constant lamp wattage.
Minimum starting
temperature is -40°C
(-40°F) for HPS and
-30°C (-20°F) for MH

• Universal ladder brackets

allow for the flexibility to
change out with other
reflectors / refractors
available in aluminum or
glass

• Mogul-base porcelain

socket

• Easily mounted prismatic

acrylic refractor has
multiple field-adjustable
distribution patterns for
precision control

• Approximate net weight:

37 lbs. (17 kgs.)

D E S C R I P T I O N

The BenchMark HB prismatic
high-bay utilizes a durable
heavy-duty die-cast aluminum
ballast housing and prismatic
acrylic reflector for maximum
durability and photometric
performance. U.L. listed and
CSA certified. Damp location
standard.

The BenchMark HB prismatic
high-bay is perfect for retail
stores, wholesale warehouses,
grocery chains, malls and
auto showrooms.

HB

16", 22" & 25"

PRISMATIC

BENCHMARK

1 7 5 - 1 0 0 0 W

H i g h P r e s s u r e S o d i u m

P u l s e S t a r t M e t a l

M e t a l H a l i d e

H E A V Y - D U T Y

P R I S M A T I C H I G H - B A Y

I N D U S T R I A L L U M I N A I R E

16" [406mm]
22" [559mm]
25" [635mm]

Maximum Height is

16"

=27 15/16" [710mm]

22"

=30 7/16" [773mm]

25"

=31 5/8" [803mm]

See ordering information

for details

NOTES: 1

Not available in 175, 200, 320, 350, 450 and 750W.

2

Approved lamp containment barrier required when enclosed rated MP/ML/MH lamps are used. 2005 NEC

code requires that open luminaires must utilize a safety glass bottom (SGB) accessory or an Open rated socket (OR) and lamp.

3

175, 200, 250, 320, 350 & 400W

only.

4

277V only, not available with HSW, HL or HC options.

5

“MD” option available on PD22 and PD25 with 250, 320, 350 or 400W Pulse Start Metal Halide

only.

6

MD available in 208, 240 or 277V or with “E” option which will operate voltages from 200-277V 50/60 Hz.

7

Factory set for concentrated, medium or wide

distributions only if P (factory pre-set) is in the nomenclature of the fixture.

8

HPS only.

9

Products also available in non-US voltages and 50Hz for international

markets. Consult factory for availability and ordering information.

10

Multi-tap ballast 120/208/240/277V wired 277V.

11

Triple-tap ballast 120/277/347V wired

347V.

12

5-tap ballast 120/208/240/277/480V wired 480V.

13

Add as suffix in the order shown.

14

Specifications and dimensions subject to change without notice.

P o w e r e d b y

t e c h n o l o g y

O R D E R I N G I N F O R M A T I O N

S A M P L E N U M B E R :

H P H B - P D 1 6 - M - 2 5 0 - M T - Q

Lamp Type
HP

=High

Pressure
Sodium

1

MH

=Metal Halide

2

MP

=Pulse Start MH (CWA)

2

ML

=Pulse Start MH (Linear Reactor)

2, 3, 4

MD

=Pulse Start Metal Halide (Electronic)

2, 5, 6

Series
HB

=High-Bay

BenchMark

Refractor Type
PD

=Prismatic

Acrylic

Refractor
Diameter
16

=16"

22

=22"

25

=25"

Socket Position/
Distribution

7

C

=Concentrated

M

=Medium

W

=Wide

Lamp
Wattage
175

=175W

200

=200W

250

=250W

320

=320W

350

=350W

400

=400W

450

=450W

600

=600W

8

750

=750W

1000

=1000W

Voltage

9

120V
208V

6

240V

6

277V

6

347V
480V
MT

=Multi-Tap

10

TT

=Triple-Tap

11

5T

=5-Tap

12

E

=Electronic

6

Options &
Accessories

13

(See Pages 541-545)

% Lamp Sur

vival

LAMP MORTALITY

2000 4000 6000

10000

8000

12000 14000 16000 18000 20000 22000 24000 26000 28000 30000

0

90

80

70

60

50

40

30

20

10

0

100

Lamp Life

[Hours]

Natural White & Uni-Form Pulse Start on ECON TECHNOLOGY Uni-Form Pulse Start on CWA Probe Start Metal Halide on CWA

TM ®

®

% Lumens

LUMEN MAINTENANCE

2000 4000 6000

10000

8000 12000

14000

16000

18000

20000

40

90

80

60

70

50

0

90% Mean Lumens Nat-Wt-ECON 86% Mean Lumens-UPS-ECON 75% Mean Lumens-UPS CWA

65% Mean Lumens-Probe Start

100

Lamp Life

[Hours]

L A M P M O R T A L I T Y A N D L U M E N M A I N T E N A N C E C O M P A R I S O N S

NOTE

: Lamp Mortality and Lumen Maintenance Charts Courtesy of VENTURE

®

Refractor

Lamp

Type

Wattage

105°C

40°C

(ECON)

*

55°C

(Open) or

40°C

(Enclosed)

**

Supply

Wire

(Min.)

Ambient

Environment

PD16

175-400W

PD22

175-450W

PD25

400-1000W

NOTES: *

Electronic Pulse Start Metal Halide.

**

PD16 enclosed is 250W only. PD25 enclosed is 400W only.