Cooper Lighting C Series - Manual

Cooper Lighting C Series

Cooper Lighting C Series – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual

691

LIGHTING INVER

TERS

C O O P E R L I G H T I N G

COOPER LIGHTING - SURE-LITES

®

• Input 120 or 277VAC

1 phase 2 wire

• Custom voltages available

• Electronic and magnetic

ballast compatible

• Generator compatibility

• Forced air cooling only

during emergency
operation, no filters
required

• 90 minute runtime standard;

other runtimes available
upon request

• 98% efficient PWM/IGBT

technology with micro-
processor control

• User programmable with

password protection

• Self-Testing and Self-

Diagnostic with Event, Test
and Alarm Logs

• RS232 communications port

• UL 924 listed

LIFEWAY II

SINGLE PHASE

C

SERIES

1 . 5 - 1 6 . 7 K V A

H I D , F l u o r e s c e n t a n d

I n c a n d e s c e n t

O N - L I N E P O W E R

I N V E R T E R S Y S T E M S

D I M E N S I O N S

D E S C R I P T I O N

The Sure-Lites Lifeway II C
Series is a single phase
inverter that provides
uninterrupted power. This
pulse width modulated
inverter utilizes IGBT
technology and has a 2
millisecond transfer time. The
unit’s operating efficiency is
98%, well above a typical fast
transfer inverter. The C Series
inverter is UL 924 Listed and
meets NFPA 101 requirements
by providing 90 minutes of
illumination for emergency
egress lighting. Other run
times and voltages are
available. Please consult your
Cooper Lighting
Representative.

A

B

C

H e i g h t

W i d t h

D e p t h

A

B

C

47"

30"

25"

S P E C I F I C A T I O N D A T A

Input Voltage

120 or 277VAC 1-phase 2 wire +10%-15%. Contact factory for all other voltages.

Input Frequency

60Hz, ±3%

Input Protection

Input Circuit Breaker

Input Harmonic Distortion

<10%

Input Power Factor

0.5 lag/lead

Output Voltage

120 or 277VAC 1-phase 2 wire. Contact factory for all other voltages.

Static Voltage

Load current change ±2%, battery discharge ±12.5%

Dynamic Voltage

±2% for ±25% load step change, ±3% for a 50% load step change, recovery within 3
cycles

Output Harmonic Distortion

<3% THD for linear load

Output Frequency

60 Hz. ±0.05Hz during emergency mode

Load Power Factor

0.5 lag to 0.5 lead

Inverter Overload

125% for 5 minutes

Output Protection

Optional Distribution Circuit Breakers

Battery

10 Year Valve-regulated Sealed Lead Calcium (standard)

Environmental

Altitude

<10,000 feet without derating

Operating Temp.

System operates safely from 0° to 40°C (32° to 104°F) up to 95% humidity. UL rating,
20° to 30°C (68° to 86°F), includes battery performance wich can be affected by
temperature. Contact factory for details.

Storage Temp.

-20° to 70°C (Electronics Only)

Humidity

<95% (non-condensing)

L I F E W AY I I S I N G L E P H A S E C S Y S T E M P A R T N U M B E R / R A T I N G / M E C H A N I C A L S P E C I F I C A T I O N S

Part

Pwr Rtg Pwr Rtg

Effic.

Audible Heat Loss UPS Cabinet Dimensions

UPS

Battery

Battery

Battery

Battery Cabinet Dimensions

No. of

Total

Total

Number

kVA

kW

@ full load

Noise

BTU

Width Height

Depth

Weight

Voltage

Current

Run

Width

Height

Depth

Battery

No.

of

System

%

db@1m

in/cm

in/cm

in/cm

lb/kg

VDC

Amperes Minutes

in/cm

in/cm

in/cm

Cabinets Cabinets

Weight (lb/kg)

ISC015

1.5

1.5

98

45

75

30/77

47/120

25/64

250/114

48

39

90

na

2

na

2

na

2

na

2

1

546/249

ISC022

2.25

2.25

98

45

100

30/77

47/120

25/64

265/121

72

38

90

na

2

na

2

na

2

na

2

1

709/323

ISC030

3.0

3.0

98

45

160

30/77

47/120

25/64

295/134

96

38

90

na

2

na

2

na

2

na

2

1

887/403

ISC037

3.75

3.75

98

45

200

30/77

47/120

25/64

305/139

120

37

90

na

2

na

2

na

2

na

2

1

1045/475

ISC048

4.8

4.8

98

45

245

30/77

47/120

25/64

315/143

144

40

90

na

2

na

2

na

2

na

2

1

1203/546

ISC060

6.0

6.0

98

45

300

30/77

47/120

25/64

350/159

180

40

90

30/77

47/120

25/64

1

2

1670/759

ISC080

8.0

8.0

98

45

400

30/77

47/120

25/64

375/171

240

39

90

30/77

47/120

25/64

1

2

2087/949

ISC100

10.0

10.0

98

45

500

30/77

47/120

25/64

435/198

144

82

90

30/77

47/120

25/64

2

3

2631/1195

ISC125

12.5

12.5

98

45

660

30/77

47/120

25/64

465/211

180

82

90

30/77

47/120

25/64

2

3

3105/1409

ISC167

16.7

16.7

98

45

840

30/77

47/120

25/64

530/241

240

80

90

30/77

47/120

25/64

2

3

3954/1795

O R D E R I N G I N F O R M A T I O N

S A M P L E N U M B E R : I S C 0 3 7 1 2 0 1 2 0

Series
ISC

=Single

Phase C

Voltage Input
120
277

ISC

KVA Rating

Voltage Output
120
277

015

=1.5

022

=2.25

030

=3.0

037

=3.75

048

=4.8

060

=6.0

080

=8.0

100

=10.0

125

=12.5

167

=16.7

Options

See page 693 for options

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Cooper Lighting Models

All Cooper Lighting Other