Page 2 - FOR THE USER; IMPORTANT; RETAIN THIS MANUAL FOR YOUR REFERENCE.; WARNING; maintenance can cause property; FOR YOUR SAFETY
FOR THE USER IMPORTANT POST IN A PROMINENT LOCATION, INSTRUCTIONS TO BE FOLLOWED IN THE EVENTTHE USER SMELLS GAS. THIS INFORMATION SHALL BE OBTAINED BY CONSULTINGYOUR LOCAL GAS SUPPLIER. KEEP APPLIANCE AREA FREE AND CLEAR FROM COMBUSTIBLES. DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATION AIR....
Page 3 - TABLE OF CONTENTS; Installation; Operating Instructions
TABLE OF CONTENTS Installation Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Shipping Damage Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 4 - GAS; INSTALLATION
1 INSPECTION Before unpacking visually inspect the unit for evidenceof damage during shipping. If damage is noticed, do not unpack the unit, followshipping damage instructions. SHIPPING DAMAGE INSTRUCTIONS If shipping damage to the unit is discovered orsuspected, observe the following guidelines inp...
Page 5 - ELECTRICAL; VENTILATION; CLEANING
2 ELECTRICAL NOTE: Wiring diagram is located on the underside of the unit's control panel. ENSURE THE ELECTRICAL SUPPLY MATCHES THEUNIT'S REQUIREMENTS AS STATED ON THE RATINGLABEL. A cord and plug are supplied with the 115 volt unit.Simply plug the unit into any grounded outlet rated for aminimum of...
Page 7 - OPERATING INSTRUCTIONS
KE95604-2 HI LO 4 OPERATING INSTRUCTIONS General Parts Drawing ITEM # DESCRIPTION FUNCTION 1. HI / OFF / LO Switch Center position - power to the unit is OFF. HI position - unit is in high fire mode (unit heats faster). LO position - unit is in low fire mode (unit heats slower). 2. Temperature Dial ...
Page 8 - OPERATING THE UNIT; OPERATING SUGGESTIONS; HOT
5 OPERATING THE UNIT 1. Ensure the gas and electrical supply to the unit arein the ON position. FOR YOUR SAFETY: This skillet will automatically shut off the gas supplywhen pan is raised more than 8°. Before commencing to cook, ensure pan is in thelowered position. 2. MANUAL TILT ( 4 ) : Cleveland s...
Page 9 - CARE AND CLEANING; NOTE; CLEANING INSTRUCTIONS
6 CARE AND CLEANING Your skillet must be cleaned regularly to maintain itsfast, efficient cooking performance, and to ensure itscontinued safe, reliable operation. WARNING: Do not use chloride base detergents. There is a growing numberof non-chloride cleaners available. Ifunsure of the cleaners chlo...
Page 10 - FAUCET ASSEMBLY; ITEM PART DESCRIPTION; SERVICE PARTS; WARRANTY
7 FAUCET ASSEMBLY ITEM PART DESCRIPTION QTY. NO. NO. 1. KE50825-7 3/4" SPOUT . . . . . . . . . . . . . . . . . . . . . . . .1 2. FA95022 RETAINING RING . . . . . . . . . . . . . . . . . . . .1 3. FA05002-19 "O" RING . . . . . . . . . . . . . . . . . . . . . . . . . . .1 4. KE51736 LONG F...
Page 12 - COMPONENT PLATE ASSEMBLY - POWER TILT
9 COMPONENT PLATE ASSEMBLY - POWER TILT ITEM NO. PART NO. DESCRIPTION QTY. 1. SK00411 COMPONENT PLATE WELDMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. KE54833-4 SNAP-IN BUSHING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 14 - TILT COMPONENTS
11 ITEM NO. PART NO. DESCRIPTION QTY. 1. KE51730 TILT SHAFT BEARING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. FA31010 LOCK WASHER, 3/8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 3. FA20030 HEX NUT, ...
Page 17 - BURNER ASSEMBLY
14 ITEM NO. PART NO. DESCRIPTION QTY. 1. SK00399-1 BURNER PAN ASSEMBLY (30 GALLON) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 SK00389-1 BURNER PAN ASSEMBLY (40 GALLON) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. SK2495500 BURNER ASSEMBLY (30 GALLON) . . . . . . ...
Page 20 - PILOT ASSEMBLY
17 PILOT ASSEMBLY ITEM PART DESCRIPTION QTY. NO. NO. 1. SK00398-1 PILOT ASSEMBLY, NATURAL GAS . . . . . .1 SK00398-2 PILOT ASSEMBLY, LP . . . . . . . . . . . . . . . .1 2. SK2460100 GASKET . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. SK2477000 IGNITOR/PILOT ASSEMBLY . . . . . . . . . . ...
Page 22 - MAINTENANCE; LUBRICATION PROCEDURE; TRUNNION; TRUNNIONS; HINGE ADJUSTMENT INSTRUCTIONS
19 MAINTENANCE WARNING : Any maintenance or service involving disassembly of components should be made by a qualified service technician. Ensure gas, electrical and water supply (if applicable) to the unit are shut off. ! LUBRICATION PROCEDURE Lubricate the following parts every three months to insu...
Page 24 - SEQUENCE OF OPERATIONS
21 SEQUENCE OF OPERATIONS When using these instructions refer to the SGL-TI wiringschematic. 1. 115 VAC is sent through the 3 amp fuse to ■ The primary of the 24 VAC transformer ❏ 24 VAC is sent from the secondary of the 24VACtransformer to the Hi/Off/Low Switch. ■ Contacts of the RI Blower Relay ■ ...
Page 25 - SPARE PARTS LIST
22 PART NO. DESCRIPTION QTY. KE50294-1 MERCURY SWITCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE53838-25 TRANSFORMER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 26 - WIRING DIAGRAM
23 WIRING DIAGRAM ELECTRICAL COMPONENTPART #s FUSE 3A KE52936-6 12 FUSE 1.25A KE52936-8 12 RELAY 1 SK2475500 17 BLOWER SK2476000 14 PILOT IGNITOR SK2477000 17 GAS CONTROL MODULE SK2475300 17 GAS VALVE (NATURAL) SK2488200 15 GAS VALVE (LP) SK2488201 15 TRANSFORMER, 24V KE53838-25 12 AIR SWITCH SK2488...
Page 27 - Symbol Legend
24 ONMARCHEENCENDIDOACCESOAN PAUSE, INTERRUPTIONPAUSE, INTERRUPTIONPAUSA, INTERRUPCIONPAUSA, INTERRUZIONEPAUSE, UNTERBRECHUNG RESETRÉENCLENCHERRECONECTARRESETNULLSTELLEN STOP OF ACTIONARRÊT DE L'ACTIONPARAR FUNCIONAMIENTOARRESTO OPERAZIONEFUNKTION STOPPEN FAST STOP, EMERGENCYARRÊT RAPIDE D'URGENCEPA...