Chromalox UB-752D - Manual

Chromalox UB-752D

Chromalox UB-752D – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
Page: / 6

Table of Contents:

  • Page 2 – WIRING; Hazard of Electric Shock. Any installation; OPERATION; Do not restrict air-flow through the heater by; MAINTENANCE; Turn off all power to service heater. Do not; WIRING DIAGRAMS; Figure 3
  • Page 3 – Figure 5; Figure 6; Figure 7
  • Page 4 – RENEWAL PARTS IDENTIFICATION; Part Number; Fuse Block Barrier; PARTS COMMON TO ALL HEATERS
  • Page 5 – Model
Loading the manual

DIVISION

4

SECTION

UB

SALES

REFERENCE

DATE

SERVICE REFERENCE

Installation, Operation

and

RENEWAL PARTS IDENTIFICATION

PF416-13

JULY, 2002

(Supersedes PF416-12)

161-048444-001

MOUNTING

© 2010 Chromalox

®

, Inc.

UB-502D and UB-752D

Forced-Air Heaters

WARNING:

Hazard of Electric Shock. Disconnect all

power before installing heater.

Note:

These heaters are designed for wall or ceiling mounting

only. Other modes of mounting voids factory warranty.

1.

Height above floor

A.

In areas where ceiling height is more than 12 feet, recom-
mended mounting height is approximately 10 feet to under-
side of heater.

B.

For ceiling heights of 12 feet or less, maximum mounting
height is determined by use of ceiling mounting brackets
offered for these heaters. Minimum spacing to ceiling is 3”
(see Figure 2).

C.

In either case, minimum mounting height is 7 feet from
floor to bottom of heater. (See Figures 1 and 2.)

2.

Spacing to adjacent walls

A.

Rear of case to back wall 4-7/8” minimum (see Figure 2).

B.

Side of case to side wall 6” minimum (see Figure 2).

3.

If two or more units are operated in the same enclosed space,
their discharges should be directed to aid in development of
mass air movement for uniform heat dispersal.

4.

Controlling thermostats to individual heaters should be
mounted at shoulder height on inside walls or columns.

‡ Model Numbers with suffix “T” added (480 volts only) are equipped with a transformer, 480V Primary — 120/240V Secondary.
‡ Model Numbers with suffix “R” added are equipped with a relay.

Horizontal

Model

Voltage and Phase

kW

Air Discharge

(Ft.)

UB-502D

120 (1ø); 208, 240 or 480 (1ø or 3ø)

5

12.5

UB-502D-R

208, 240 or 480 (1ø or 3ø)

5

12.5

UB-752D

120 (1ø); 208, 240 or 480 (1ø or 3ø)

7.5

13

UB-752D-R

208, 240 (3ø); 480 (1ø or 3ø)

7.5

13

Specifications —

Dimensions —

Rubber Feet Provided for

Wall Mount Units Only.

7/8” and 1-13/32”
Dia. Holes in Rear

11-5/8”

13-5/8”

17-3/16”

8-7/8”

7-9/16”

For Lower Height
from Ceiling:
Customer to add
Extension Strap.

11-7/8”

8”

6”

7’-0” Min. Height

Above Floor

Figure 1

Mounting UB using ceiling

mounting brackets*

Ceiling Line

Wall

Back

Wall

6” Min. Spacing to

Adjacent Wall

3”

4-7/8”

8-7/8”

15-9/16”

7’-0” Min. Height

Above Floor

Mounting

Holes

Center

8”

6”

Figure 2

Mounting UB using wall

mounting brackets*

*Wall and/or Ceiling Mounting Brackets are
available as an accessory option — Contact
local sales representative.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - WIRING; Hazard of Electric Shock. Any installation; OPERATION; Do not restrict air-flow through the heater by; MAINTENANCE; Turn off all power to service heater. Do not; WIRING DIAGRAMS; Figure 3

WIRING Note: All wiring should be done in accordance with local codes and the National Electrical Code by a qualified person. WARNING: Hazard of Electric Shock. Any installation involving electric heaters must be effectivelygrounded in accordance with the National ElectricalCode to eliminate shock h...

Page 3 - Figure 5; Figure 6; Figure 7

WIRING DIAGRAMS } C1T1T2 F1F2 L1 L2L3 Alternate 240V Wiring Integral 480V/240V or 120V Transformer Thermal Cutout Ground Heater Bank 1Ø Motor Heater Wiring Comp't Baffle For 3 Phase Only 120V Wiring X1 X3 X2 X4 X1 X3 X2 X4 H1 H2 This Wiring by Customer Control Switch Optional ThermostatWhen Used Con...

Page 4 - RENEWAL PARTS IDENTIFICATION; Part Number; Fuse Block Barrier; PARTS COMMON TO ALL HEATERS

RENEWAL PARTS IDENTIFICATION ‡ Note: Only one thermal cutout is used if a Transformer and/or Relay is used. Note: Part numbers suffixed by a number in ( ) indicates quantity of same part number used. * Fusing Parts Part Number Fuse 3 Amp 600V KTK-3 128-047763-007 (2) Fuse Block Barrier 129-048475-00...

Other Chromalox Models

All Chromalox Other