Chromalox UB-1502E - Manual

Chromalox UB-1502E

Chromalox UB-1502E – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
Page: / 6

Table of Contents:

  • Page 2 – WIRING; Users should install adequate back-up; OPERATION; MAINTENANCE; Turn off all power to service heater. Do; WIRING DIAGRAMS; Figure 3
  • Page 3 – Figure 4
  • Page 4 – Figure 7
  • Page 5 – RENEWAL PARTS IDENTIFICATION
  • Page 6 – PARTS COMMON TO ALL HEATERS; Ceiling Mounting Support (Includes
Loading the manual

DIVISION

4

SECTION

UB

SALES

REFERENCE

DATE

SERVICE REFERENCE

Installation, Operation

and

RENEWAL PARTS IDENTIFICATION

PF417-14

161-048445-001

July, 2002

(Supersedes PF417-13)

MOUNTING

© 2010 Chromalox

®

, Inc.

WARNING:

Hazard of Electric Shock. Disconnect all

power before installing heater.

Note:

These heaters are designed for wall or ceiling mounting

only. Other modes of mounting voids factory warranty.

1.

Height above floor

A.

In areas where ceiling height is more than 12 feet, recom-
mended mounting height is approximately 10 feet to under-
side of heater.

B.

For ceiling heights of 12 feet or less, maximum mounting
height is determined by use of ceiling mounting brackets
offered for these heaters. Minimum spacing to ceiling is 3”
(see Figure 2).

C.

In either case, minimum mounting height is 7 feet from
floor to bottom of heater (see Figures 1 and 2).

2.

Spacing to adjacent walls

A.

Rear of case to back wall 4-7/8” minimum (see Figure 2).

B.

Side of case to side wall 6” minimum (see Figure 2).

3.

If two or more units are operated in the same enclosed space,
their discharges should be directed to aid in development of
mass air movement for uniform heat dispersal.

4.

Controlling thermostats to individual heaters should be
mounted at shoulder height on inside walls or columns.

‡ Models with suffix “T” added (480 volts only) are equipped with a transformer, 480 volt primary — 120/240 volt secondary.
‡ Models with suffix “R” added are equipped with a relay (Example: UB-1002E-R 240 volt or 480 volt — 3 phase only).

Horizontal

Model

Volts and Phase

kW

Air

Discharge

UB-1002E

208 - 240 - 480 (1 or 3)

10

40’

UB-1252E

208 (3) - 240 (3) - 480 (1 or 3)

12.5

40’

UB-1502E

208 (3) - 240 (1 or 3) - 480 (1 or 3)

15

45’

UB-2002E

240 (1 or 3)

19.9

45’

UB-2002E

208 (3) - 480 (1 or 3)

20

45’

Specifications —

Dimensions —

Rubber Feet Provided for

Wall Mount Model Only.

7/8” and 1-23/32”
Dia. Holes in Rear

13-3/4”

17-1/8”

20-3/4”

11-3/4”

9-5/16”

For Lower Height
from Ceiling:
Customer to Add
Extention Strap

12-1/4”

8”

6”

7’-0” Min.

Height Above

Floor

Figure 1

Mounting UB using

Ceiling Mounting

Brackets*

Ceiling Line

Wall

Back

Wall

6” Min. Spacing to

Adjacent Wall

3”

4-7/8”

Min.

11-3/4”

17-11/16”

7’-0” Min. Height

Above Floor

Mounting

Holes Center

10”

8”

Figure 2

Mounting UB using Wall

Mounting Brackets*

*Wall and/or Ceiling Mounting Brackets are
available as an accessory option — Contact
your local sales representative.

Type UB-1002E, UB-1252E, UB-1502E, UB-2002E

Forced-Air Heaters

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - WIRING; Users should install adequate back-up; OPERATION; MAINTENANCE; Turn off all power to service heater. Do; WIRING DIAGRAMS; Figure 3

WIRING Note: All wiring should be done in accordance with local codes and the National Electrical Code by a qualified person. WARNING: Hazard of Electric Shock. Any installa- tion involving electric heaters must be effectivelygrounded in accordance with the NationalElectrical Code to eliminate shock...

Page 3 - Figure 4

WIRING DIAGRAMS } C1T1 T2F1 F2 L1 L2 L3 Alternate 240V Wiring Integral 480V/240V or 120V Transformer Thermal Cutout Transformer Fusing Ground Heater Bank 1Ø Motor Heater Wiring Comp't Baffle For 3 Phase Only 120V Wiring X1 X3 X2 X4 X1 X3 X2 X4 H1 H2 This Wiring by Customer Control Switch Optional Th...

Page 4 - Figure 7

WIRING DIAGRAMS Integral Contactor Ground Heater Bank 1Ø Motor Heater Wiring Comp't Baffle For 3 Phase Only } This Wiring bny Customer ThermostatWhen Used 1 or 3 Phase, 60 CyclePower Supply 208 or 240 Volts Fused Switch Cutout T1 T2 L1L2 L3 Figure 7 Use with: UB-1002E-R 208V, 1Ø or 3Ø240V, 1Ø or 3Ø ...

Other Chromalox Models

All Chromalox Other