Installation, Operation
and
Maintenance Instructions
PD437-4
161-074306-001
SEPTEMBER, 1998
(Supersedes PD437-3)
© 2010 Chromalox, Inc.
Tuff-Tube
™
One and Tuff-Tube
™
Three
PFA Teflon
®
Thermoplastic Covered Metal Sheath
Over-the-Side Immersion Heater
TUFF-TUBE
™
ONE (TPR)
Dimensions (In.)
Model
Watts
Volts
Phase
A
B*
C**
D
TPR-101
1000
120
1
13
6
7
15
TPR-102
240
1
TPR-202
2000
240
1
21
12
9
23
TPR-204
480
1
TPR-302
3000
240
1
26
17
9
28
TPR-304
480
1
TPR-402
4000
240
1
31
22
9
33
TPR-404
480
1
TPR-602
6000
240
1
42
33
9
44
TPR-604
480
1
TPR-802
8000
240
1
53
44
9
55
TPR-804
480
1
Specifications — Type TPR — Figure 1
TUFF-TUBE
™
THREE (TPF)
Dimensions (In.)
Model
Watts
Volts
Phase
A
B*
C**
D
TPF-302
3000
240
3
20
11
9
22
TPF-304
480
3
TPF-402
4000
240
3
23
14
9
25
TPF-404
480
3
TPF-602
6000
240
3
30
21
9
32
TPF-604
480
3
TPF-802
8000
240
3
37
28
9
39
TPF-804
480
3
TPF-1002
10000
240
3
44
35
9
46
TPF-1004
480
3
Specifications — Type TPF — Figure 2
*B Dimension is heated section.
**C Dimension is cold section.
*B Dimension is heated section.
**C Dimension is cold section.
A
C
B
D
7/8 Dia. each side
for 1/2 in. conduit
Tank Lip
Plastic guard cover removed
for illustration purposes.
D
Plastic guard cover removed
for illustration purposes.
Mounting Hole Location
7/8 Dia. each side
for 1/2 in. conduit
Tank Lip
A
C
B
Mounting Hole Location
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
GENERAL WARNING: This heater is not intended for use in hazardous atmospheres where flammable vapors,gases, liquids or other combustible atmospheres arepresent as defined in the National Electrical Code.Failure to comply can result in explosion or fire. Chromalox type TPR and TPF over-the-side immer...
Cutout Ground 120V or 240VControl Circuit Factory Field Green Line Voltage 3 Pole Contactor (Customer Supplied) 1 2 1 3 2 3 C1 C2 1 2 Cutout Ground Factory Field Green 120V Line Voltage C2 C1 WIRING DIAGRAMS 1 2 C2 C1 Line Voltage 2 Pole Contactor (Customer Supplied) Cutout Ground Factory Field Gree...
Cutout Ground 120V or 240VControl Circuit Factory Field Green Line Voltage 3 Pole Contactor (Customer Supplied) 1 2 3 1 2 3 C1 C2 2150 N. RULON WHITE BLVD., OGDEN, UT 84404 Phone: 1-800-368-2493 www.chromalox.com T A - Q 0 - E F Litho in U.S.A. WIRING DIAGRAMS Figure 6 Three Phase (TPF-602, -604, -8...