- Page 2 – INSTALLATION INSTRUCTIONS; INSTRUCTIONS FOR INSTALLING DISCONNECT SWITCH ON; The disconnect switch kit includes the following parts.
- Page 4 – INSTRUCTIONS FOR INSTALLING WALL MOUNTED STAR-GF; The ground fault sensor has been factory set at .03 Amps,; DO; Table 2; STAR-GF Mounting Dimensions; The Chromalox STAR-GF ground fault sensor provides a reli-; DANGER: Hazard of Electric; MAINTENANCE; GF TROUBLESHOOTING DIAGRAM
- Page 5 – INSTRUCTIONS FOR INSTALLING “STAR-TIP” AND “STAR-TG” ON
- Page 6 – The Chromalox STAR-TG tip over cutout with ground fault; TG TROUBLESHOOTING DIAGRAM
- Page 7 – WIRING; For applicable wiring diagram see Table 1
- Page 8 – RENEWAL PARTS IDENTIFICATION
(Supersedes PG436-1)
PG436-2
VTS
161-304901-004
JUNE, 2010
4
DATE
SALES
REFERENCE
DIVISION
SECTION
Chromalox
®
DS-50600, STAR-GF, STAR-TIP and STAR-TG Kits
For Adding Optional Kits to STAR Radiant Heaters
© 2008 Chromalox, Inc.
Table 1
Kit Model
Used with Heater Model
Kit Function
Installation Instructions
Wiring Diagram
DS-50600
Fixed STAR-06A and STAR-14A
Adds Integral Disconnect Switch
See Page 2
Fig. 1
DS-50600
Portable STAR-06A and STAR-14A
Adds Integral Disconnect Switch
See Page 3
Fig. 1
STAR-GF
All Fixed STAR
Adds Wall Mounted Ground Fault Sensor
See Page 4
Fig. 2
STAR-TIP
Portable STAR-06A and STAR-14A
Adds Tip Over Shut Down
See Page 5
Fig. 3
STAR-TG
Portable STAR-06A and STAR-14A
Adds Tip Over Shut Down with Ground Fault Sensor
See Pages 5 and 6
Fig. 4
GENERAL
To use this instruction sheet from Table 1 select the Installation
Instructions by matching the Kit Model to the Heater Model. If a
match does not exist consult Factory.
The kits are add-on options to STAR Radiant Heaters. The
installation and renewal parts identification for the heater is cov-
ered in the instruction sheet provided with the heater.
SAVE
BOTH COPIES OF THE INSTRUCTION SHEET.
ELECTRIC SHOCK HAZARD. Disconnect all power
to heater before installing or servicing kit(s).
Failure to do so could result in personal injury or
property damage. Kit(s) must be installed by a
qualified person in accordance with the National
Electrical Code, NFPA 70.
Always check to make certain the voltage rating of the kit
matches the voltage rating of the heater (See Nameplates).
Model DS50600
STAR-GF
Model STAR-TIP
STAR-TG
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 Cover(Step 4) 3 Pole Terminal Block w/Ground(Step 8) Opening for 1" Conduit Fitting(Step 8) 3 Pole Disconnect Switch On-Off Handle Chase Nipple and Gasket(Step 5) Cover(Step 3) INSTALLATION INSTRUCTIONS INSTRUCTIONS FOR INSTALLING DISCONNECT SWITCH ON 6 AND 13.5 KW FIXED RADIANT HEATERS 1. Add...
4 INSTRUCTIONS FOR INSTALLING WALL MOUNTED STAR-GF 1. Check voltage on heater nameplate and STAR-GF to make cer-tain voltages are the same. If voltages do not match, consultfactory. 2. The STAR-GF will provide ground fault protection for STARRadiant heaters. The number of heaters serviced by one (1)...
5 VIEW SHOWN WITH TIP OVER SWITCH ASSY COVER REMOVED MOUNTING BRACKET (STEP 4) 3/8" LOCKWASHER AND NUT (STEP 4) SELF TAPPING SCREW (STEP 8) HEAT/NO HEAT 3 POLE CONTACTOR OPENING FOR 1" CORD FITTING (STEP 11) CHASE NIPPLE AND GASKET (STEP 6) COVER (STEP 3) INSTALLATION INSTRUCTIONS INSTRUCTIO...