Chromalox CES-6 - Manual

Chromalox CES-6

Chromalox CES-6 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 2 – DIMENSIONS
  • Page 3 – Model; When installing boiler, allow sufficient room (21” minimum) to
  • Page 4 – Diagram 1; WIRING; Hazard of Electric Shock. Boiler must be; SPECIAL INSTRUCTIONS FOR CUSTOMERS SUPPLY-; Export
  • Page 5 – Diagram 2; TYPICAL WIRING DIAGRAMS; Diagram 3
  • Page 6 – Diagram 4; Diagram 5
  • Page 7 – Diagram 6; Diagram 7
  • Page 8 – Diagram 8; Diagram 9
  • Page 11 – This is to prevent possible element; Turn boiler switch to “ON” position,; pump or solenoid; Checking low water cutout switch operation,; open drain; Turn off boiler. Reinstall contactor; Be sure all electrical connections are tight; Typical Export Boiler; Figure 1; — Automatic Reset Low-Water Cutoff Junction Box
  • Page 12 – CUT OUT; ting minus the differential setting, equals; CUT IN; pressure of the; HIGH LIMIT PRESSURE CONTROL OPERATION; This is for test purposes only!; Figure 2; OPERATION; For best boiler performance, a 1/4” less steam valve; MANUAL BLOWDOWN INSTRUCTIONS; Blowdown is an essential part of boiler operation. It is the best
  • Page 13 – INITIAL TESTING —; Automatic Blowdown Control Cabinet; Display View of Automatic Blowdown Control Cabinet; Wiring Diagram for Automatic Blowdown
  • Page 14 – OPTIONAL EQUIPMENT FOR STEAM BOILERS; Control will not work with de-ionized or de-; Main Setting —; Typical Wiring for; Electronic Resistance Sensing
  • Page 15 – IF A CONTROLLER SEEMS TO OPERATE IMPROPERLY; Solid State Sequencer.; Solid State Sequencer
  • Page 16 – Hazard of Electric Shock. Water feed system; CONDENSATE RETURN SYSTEMS; WATER FEED SYSTEMS; Pump Motor Dimensions
  • Page 17 – Installation; MAINTENANCE; Sequence
  • Page 18 – HEATER ELEMENT CONDITION PROBABLE CAUSE; Faulty weld or braze on element to flange connection or corrosion.; IMMERSION HEATER FAILURE CAUSES
  • Page 19 – RENEWAL PARTS IDENTIFICATION
Loading the manual

3 Phase Voltages*

Output

Quantity and Rating

No./kW

Elec

at

of Contactors

of

Rating Cap.

Vol.

212˚F

Heating

Model

(BHP) (kW) (Gals.) (Lbs./Hr.) 208

240

480† Elements

Type CES — 0-100 PSIG

CES-6

.6

6

6

18

30

30

30

1-6

CES-9

.9

9

6

27

30

30

30

1-9

CES-12

1.22

12

6

36.2

40

30

30

1-12

CES-18

1.73

17

6

51.2

50

50

30

1-17

CES-24

2.45

24

14.3

72.3

2-40

2-30

2-30

2-12

1-40

1-40

1-12

CES-30

2.95

29

14.3

87.4

1-50

1-30

40

1-17

CES-36

3.47

34

14.3

102.5

2-50

2-50

50

2-17

1-40

1-30

1-40

1-12

CES-48

4.69

46

14.3

138.7

2-50

2-50

1-30

2-17

2-50

2-30

2-12

CES-60

5.91

58

14.3

174.8

2-40

2-50

2-40

2-17

CES-72

6.93

68

14.3

205

4-50

4-50

2-50

4-17

CES-100

10.40

102

27.8

307

6-50

6-50

3-50

6-17

CES-135

13.9

136

30.5

410

8-50

4-50

8-17

1-30

CES-160

16.1 157.5

30.5

475

7-60

3-60

7-22.5

CES-180

18.4

180

30.5

543

8-60

4-60

8-22.5

Chromalox

®

DIVISION

4

SECTION

CES

SALES

REFERENCE

DATE

SERVICE REFERENCE

Installation, Operation

and

RENEWAL PARTS IDENTIFICATION

PQ444-1

MAY, 1999

(Supersedes PQ444)

161-562789-002

© 2010 Chromalox, Inc.

Type CES-6 through CES-180 Electric Steam Boiler

Standard Trim is 100 PSI — 0-90 Operating Pressure Range

Boiler Serial Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Circuit Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Control Circuit Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

National Board No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Amps . . . . . . . . . . . . . . . Phase . . . . . . . . . . . Cy . . . . . . . . . .

Important —

This data file contains the National Board Registration Certificate for your boiler. It must be kept near the boiler at all times.

* Single phase available up to and including 24 kW capacity.
† All boilers must have separate 120V Control Circuit or Transformer.
Boilers under 40 amps max are not fused.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - DIMENSIONS

MODEL CES-24 through CES-180 MODEL CES-6 through CES-18 DIMENSIONS DrainBlowdownValve K A C H B D E F G Check Valve L OptionalTransformer Safety ValveOutlet J Manual ResetHigh Limit ControlOptional VacuumBreaker McDonnell & MillerLow Water CutoffPump Control Drain BlowdownValve OperatingPressure...

Page 3 - Model; When installing boiler, allow sufficient room (21” minimum) to

Typical Plumbing Installation of a Steam Boiler with Condensate Return System CES — Dimensions (In.) DIMENSIONS INSTALLATION Model A B* C D E F G H I J K L CES-6 37 22-1/2 30 15-1/4 20 30-1/2 9-1/2 16 1/2 1 1/2 1/2 CES-9 37 22-1/2 30 15-1/4 20 30-1/2 9-1/2 16 1/2 1 1/2 1/2 CES-12 37 22-1/2 30 15-1/4...

Page 4 - Diagram 1; WIRING; Hazard of Electric Shock. Boiler must be; SPECIAL INSTRUCTIONS FOR CUSTOMERS SUPPLY-; Export

Diagram 1 3 Phase Voltage 3 Phase Voltage 3 Phase Voltage Boiler 208 240 480 Boiler 208 240 480 Boiler 208 240 480 WIRING TYPICAL WIRING DIAGRAMS WARNING: Hazard of Electric Shock. Boiler must be suitably grounded according to N.E.C. standard. 1. Be sure to use the proper wire. Electric wiring to bo...

Other Chromalox Models

All Chromalox Other