(Supersedes PF492)
PF492-1
JULY, 2002
Draft Barrier Heaters
Type CAF-6 and CCAS-8
© 2010 Chromalox, Inc.
TABLE 1 —
Spe
cification
s
CA
F
-6
CCA
S
-8
Dimensions (In.)
Model
Model
Volts
Phase
Watts
Amps
BTUH
Height
Length
Depth
Weight (Lbs.)
CAF-6F205
CCAS-8F205
120
1
500
4.2
1,706
6/7.5
24.3
2.5
7
CAF-6F205
CCAS-8F205
208
1
500
2.4
1,706
6/7.5
24.3
2.5
7
CAF-6F205
CCAS-8F205
240
1
500
2.1
1,706
6/7.5
24.3
2.5
7
CAF-6F205
CCAS-8F205
277
1
500
1.8
1,706
6/7.5
24.3
2.5
7
CAF-6F307
CCAS-8F307
120
1
750
6.3
2,559
6/7.5
36.3
2.5
9.5
CAF-6F307
CCAS-8F307
208
1
750
3.6
2,559
6/7.5
36.3
2.5
9.5
CAF-6F307
CCAS-8F307
240
1
750
3.1
2,559
6/7.5
36.3
2.5
9.5
CAF-6F307
CCAS-8F307
277
1
750
2.7
2,559
6/7.5
36.3
2.5
9.5
CAF-6F410
CCAS-8F410
120
1
1000
8.3
3,412
6/7.5
48.3
2.5
12
CAF-6F410
CCAS-8F410
208
1
1000
4.8
3,412
6/7.5
48.3
2.5
12
CAF-6F410
CCAS-8F410
240
1
1000
4.2
3,412
6/7.5
48.3
2.5
12
CAF-6F410
CCAS-8F410
277
1
1000
3.6
3,412
6/7.5
48.3
2.5
12
CAF-6F512
CCAS-8F512
120
1
1250
10.4
4,265
6/7.5
60.3
2.5
15
CAF-6F512
CCAS-8F512
208
1
1250
6
4,265
6/7.5
60.3
2.5
15
CAF-6F512
CCAS-8F512
240
1
1250
5.2
4,265
6/7.5
60.3
2.5
15
CAF-6F512
CCAS-8F512
277
1
1250
4.5
4,265
6/7.5
60.3
2.5
15
CAF-6F615
CCAS-8F615
120
1
1500
12.5
5,118
6/7.5
72.3
2.5
18
CAF-6F615
CCAS-8F615
208
1
1500
7.2
5,118
6/7.5
72.3
2.5
18
CAF-6F615
CCAS-8F615
240
1
1500
6.3
5,118
6/7.5
72.3
2.5
18
CAF-6F615
CCAS-8F615
277
1
1500
5.4
5,118
6/7.5
72.3
2.5
18
CAF-6F717
CCAS-8F717
208
1
1750
8.4
5,971
6/7.5
84.3
2.5
21.5
CAF-6F717
CCAS-8F717
240
1
1750
7.3
5,971
6/7.5
84.3
2.5
21.5
CAF-6F717
CCAS-8F717
277
1
1750
6.3
5,971
6/7.5
84.3
2.5
21.5
CAF-6F820
CCAS-8F820
208
1
2000
9.6
6,824
6/7.5
96.3
2.5
25
CAF-6F820
CCAS-8F820
240
1
2000
8.3
6,824
6/7.5
96.3
2.5
25
CAF-6F820
CCAS-8F820
277
1
2000
7.2
6,824
6/7.5
96.3
2.5
25
CAF-6F922
CCAS-8F922
208
1
2250
10.8
7,677
6/7.5
108.3
2.5
29
CAF-6F922
CCAS-8F922
240
1
2250
9.4
7,677
6/7.5
108.3
2.5
29
CAF-6F922
CCAS-8F922
277
1
2250
8.1
7,677
6/7.5
108.3
2.5
29
CAF-6F025
CCAS-8F025
208
1
2500
12
8,530
6/7.5
120.3
2.5
33
CAF-6F025
CCAS-8F025
240
1
2500
10.4
8,530
6/7.5
120.3
2.5
33
CAF-6F025
CCAS-8F025
277
1
2500
9
8,530
6/7.5
120.3
2.5
33
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
MODEL NUMBER DESCRIPTION This document explains the correct procedure for the installa- tion and safe operation of all models of Draft Barrier and PedestalMounted Heaters. Draft Barrier Heating Systems are designed to be installed in accordance with the National Electrical Code and with local codesb...
Draft Barrier Heater Installation (Wall)1. Once the correct mounting height is established, scribe or snapa level line on the wall to maintain each heater back plate inhorizontal alignment, when mounting. 2. Remove heater front cover by lifting top rear edge to unsnapcover from back plate (store cov...
2150 N. RULON WHITE BLVD., OGDEN, UT 84404 Phone: 1-800-368-2493 www.chromalox.com Table 3: Service Supply Wiring Sizes Recommended Minimum supply wire sizes are listed in the tablebelow: 1. Wire all heaters and controls in accordance with the appropri-ate wiring diagram provided on page 4. 2. Run a...