Chamberlain 942FPC - Manual

Chamberlain 942FPC

Chamberlain 942FPC – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – Tips for Success; CORRECT; Reference; Step 3 Enroll Initial User
  • Page 3 – Step 5 Programming; The unit must have an enrolled user before it can be; The Retry LED will light if another; Step 6 Operation; slowly; If cover is already open, press either the Resend or the
  • Page 4 – Troubleshooting; To prevent possible SERIOUS INJURY or DEATH:
  • Page 5 – Ouverture sans clé à empreintes digitales; Caractéristiques; VERTISSEMENT
  • Page 6 – Conseils utiles; ERRONÉ; Référence
  • Page 7 – Étape 5 Programmation; Étape 6 Fonctionnement
  • Page 8 – Suppression/Réinitialisation; Dépannage
Loading the manual

®

Model 942FPC

Fingerprint Keyless Entry

Overview

The system uses biometric technology that enables an
authorized user to gain access by scanning their fingerprint.
The sensor strip on the unit makes a numeric template of the
fingerprint that is unique to that user. The unit’s memory can
store up to four fingerprints.

The term “enroll” refers to scanning the fingerprint so the
device will recognize the user.

The term “swipe” refers to the movement of the finger across
the sensor strip.

The term “LED” stands for Light Emitting Diode. There are
6 LEDs located on the Fingerprint Keyless Entry.

When unit is on, it is programmed to shut off after a short
period of time. The unit’s sensor strip is sensitive so it is
important to read the Tips for Success before attempting to
use the Fingerprint Keyless Entry.

Carton Inventory

Recei

v

er

Fingerprint Keyless
Entry

ENROLL

SEND

ENROLL

PASS

FAIL

READY

RETRY

Step 1 Install the Receiver

1. Unplug the opener before proceeding.

2. OPEN RECEIVER: Insert a small screwdriver in slot on

receiver front panel as shown. Twist up actuator cover.

3. CONNECT RECEIVER AND OPENER: Remove about 1/4"

(6 mm) of insulation from each end of the 2-strand bell wire.
Connect one end to the receiver screw terminals (polarity is
NOT required). Route wire along the channels and out the
bottom as shown.

4. Connect the other end of the bell wire to the two opener

terminals labeled “2” (white) and “1” (red), “common” and
“command” or the terminals used for the push button control.

5. Use insulated staples to secure bell wire between receiver

and opener. Length of bell wire depends on where the
receiver will be installed. Replace actuator cover.

6. Choose a 120Vac polarized outlet for the receiver which is

OUT OF THE REACH OF CHILDREN. Plug receiver into
selected outlet. Return power to the opener.

Act

u

ator Co

v

er

Po

w

er Indicator Light

Terminals

Bell

W

ire

Channels

“SMART”
Indicator
Light

Connect Bell

W

ire

To Garage Door
Opener Terminals

“SMART”
Act

u

ator

Bell

W

ire

To prevent possible SERIOUS INJURY or DEATH from electrocution:
• Be sure power is not connected BEFORE installing the receiver.
To prevent possible SERIOUS INJURY or DEATH from a moving
gate or garage door:
• Install Keyless Entry Control within sight of the garage door, out of

reach of children at a minimum height of 5 feet (1.5 m), and away
from all moving parts of door.

• ALWAYS keep remote controls out of reach of children. NEVER

permit children to operate, or play with remote controls.

• Activate gate or door ONLY when it can be seen clearly, is properly

adjusted, and there are no obstructions to door travel.

• ALWAYS keep gate or garage door in sight until completely closed.

NEVER permit anyone to cross path of moving gate or door.

NOTICE TO U. S. CONSUMERS:

Some states prohibit the service or repair of garage door openers which
cannot be made to comply with the safety standards contained in UL
325 (1988 revision). In order to comply with both the letter and the spirit
of these laws, this universal radio control should not be used with
any LiftMaster

®

, Chamberlain

®

, or Sears Craftsman

®

garage door

opener manufactured prior to April 1, 1982. To find out if your
Chamberlain-made garage door opener was manufactured prior to or
after April 1, 1982, please call 1-800-528-9131 before installing this
universal radio control.

Step 2 Install the Keyless Entry

1. Remove cover.

2. Fasten bottom screw to mounting surface. Allow 1/8"

(3 mm) to protrude above surface. Position unit on screw
head and adjust for snug fit.

3. Fasten top screw. Replace cover.

1

3

2

1

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Tips for Success; CORRECT; Reference; Step 3 Enroll Initial User

Tips for Success CORRECT 1. Make sure finger is clean and dry. Place finger flat above the sensor strip with the top knuckle above the sensor. 2. Swipe finger straight down keeping firm contact with the sensor. The swipe should be a slow, constant speed. SPECIAL NOTES: Use the same finger for every ...

Page 3 - Step 5 Programming; The unit must have an enrolled user before it can be; The Retry LED will light if another; Step 6 Operation; slowly; If cover is already open, press either the Resend or the

Step 5 Programming NOTE: The unit must have an enrolled user before it can be programmed to the receiver. Due to the 30 second time interval, a second person may be needed to press the “SMART” actuator. 1. Remove the front panel of the receiver case. Press and release the “SMART” actuator on the rec...

Page 4 - Troubleshooting; To prevent possible SERIOUS INJURY or DEATH:

Erase/Reset • To erase users: NOTE: Erasing a user will erase ALL stored fingerprints. User does NOT need to reprogram to opener. 1. Open cover and wait until Ready LED is lit. 2. Enrolled user must slowly and firmly swipe fingerprint. 3. Press and hold the Enroll button for at least 6 seconds. The ...

Other Chamberlain Models