Carrier GAPAAXCC1625- User Manual
Carrier GAPAAXCC1625– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – APPLICATION CONSIDERATIONS; Air Conditioning; NOTE; WARNING; Transitions; GAP
- Page 3 – INSTALLATION; Check Infinity Air Purifier Components; CAUTION; Identify Mounting Location
- Page 4 – Fig. 4 -- Infinity Air Purifier Cabinet Orientation with Transition
- Page 5 – Mount Cabinet; ELECTRICAL SHOCK HAZARD; UNIT DAMAGE HAZARD
- Page 6 – Wiring; Checking Air Purifier Operation
- Page 7 – MAINTENANCE; To replace the air purifier cartridge, complete the; Turn the heating and cooling system power; Turn heating and cooling system power off.
- Page 8 – POINTS ARE SHARP! BE VERY CAREFUL DURING CLEANING.; TROUBLESHOOTING; SAFETY HAZARD
- Page 9 – Table 1 – Troubleshooting
- Page 10 – SPECIFICATIONS AND DIMENSIONS; Table 2 – Specifications and Dimensions; SPECIFICATIONS
- Page 11 – Limited Warranty for Air Purifier
GAPAA
Infinity™ Air Purifier
Sizes 1625 and 2025
Installation Instructions
NOTE
: Read the entire instruction manual before starting the
install.
TABLE OF CONTENTS
PAGE
INTRODUCTION
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HOW IT WORKS
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SAFETY CONSIDERATIONS
1
. . . . . . . . . . . . . . . . . . . . . . . . .
APPLICATION CONSIDERATIONS
2
. . . . . . . . . . . . . . . . . . . .
INSTALLATION
3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
START--UP AND OPERATION
6
. . . . . . . . . . . . . . . . . . . . . . . .
MAINTENANCE
7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TROUBLESHOOTING
9
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SPECIFICATIONS AND DIMENSIONS
10
. . . . . . . . . . . . . . . .
WARRANTY
11
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INTRODUCTION
Congratulations for selecting the Infinity Air Purifier for your
home comfort system! The Infinity Air Purifier is proven to
remove and kill airborne germs and allergens, including viruses,
bacteria, and mold spores. The Infinity Air Purifier is a cornerstone
of Carrier’s Healthy Home Solutions for providing healthier,
cleaner air in your home.
HOW IT WORKS
The Infinity Air Purifier provides extremely high filtration
performance while killing captured contaminants, including
viruses, bacteria, and mold spores. The Infinity Air Purifier treats
the entire air--stream through a state of the art, three--stage process.
In stage one, the particles are electrically charged by a
precision--point ionization array as they enter the Infinity Air
Purifier.
In stage two, the charged particles are electrically attracted to the air
purification cartridge, which is located within an electric field.
In stage three, captured particles are killed by electrical current
flow and ion bombardment.
The Infinity Air Purifier is CSA certified for shock and electrical
fire hazard only.
La Infinity Air Purifier certification CSA vise uniquement les
risques de choc electrique et.
A05265
Fig. 1 -- GAPAA Unit
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service, maintenance,
or use can cause explosion, fire, electrical shock, or other
conditions which may cause death, personal injury or property
damage. Consult a qualified installer, service agency or your
distributor or branch for information or assistance. The qualified
installer or agency must use factory--authorized kits or accessories
when modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,
and work gloves. Have a fire extinguisher available. Read these
instructions thoroughly and follow all warnings and cautions
included in literature and attached to the unit. Consult local
building codes and the current edition of the National Electrical
Code (NEC) NFPA 70.
In Canada, refer to the current editions of the Canadian Electrical
Code CSA C22.1.
Recognize safety information. When you see this symbol
on
the unit and in instructions or manuals, be alert to the potential for
personal injury. Understand the signal words
DANGER
,
WARNING
, and
CAUTION
. These words are used with the
safety--alert symbol.
DANGER
identifies the most serious hazards,
which
will
result in severe personal injury or death.
WARNING
signifies hazards, which
could
result in personal injury or death.
CAUTION
is used to identify unsafe practices, which
may
result
in minor personal injury or product and property damage.
NOTE
is used to highlight suggestions which
will
result in enhanced
installation, reliability, or operation.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 APPLICATION CONSIDERATIONS The Infinity Air Purifier is designed for use in the return air duct ofa forced air heating, cooling, and ventilation system. Models GAPAAXCC1625 and GAPAAXCC2025 are specifically designed for use in systems with a forced air gas furnace. Air Conditioning The Infinity Ai...
3 INSTALLATION Check Infinity Air Purifier Components CUT HAZARD Failure to follow this caution may result in personal injury.Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing and gloves when handling parts. CAUTION ! Carefully remove all items from t...
4 Downflow 14” Furnacewith Top Mount Upflow 14” Furnacewith Bottom Mount Horizontal 14” Furnacewith Side Mount Plenum Box Upflow Furnacewith Plenum Box Horizontal 24” Furnace Downflow 24” Furnacewith Top Mount Upflow 24” Furnace On Standwith Bottom Mount Upflow Furnace Note: When transitioning betwe...