Page 2 - APPLICATION CONSIDERATIONS; Air Conditioning; NOTE; WARNING; Transitions; GAP
2 APPLICATION CONSIDERATIONS The Infinity Air Purifier is designed for use in the return air duct ofa forced air heating, cooling, and ventilation system. Models GAPAAXCC1625 and GAPAAXCC2025 are specifically designed for use in systems with a forced air gas furnace. Air Conditioning The Infinity Ai...
Page 3 - INSTALLATION; Check Infinity Air Purifier Components; CAUTION; Identify Mounting Location
3 INSTALLATION Check Infinity Air Purifier Components CUT HAZARD Failure to follow this caution may result in personal injury.Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing and gloves when handling parts. CAUTION ! Carefully remove all items from t...
Page 4 - Fig. 4 -- Infinity Air Purifier Cabinet Orientation with Transition
4 Downflow 14” Furnacewith Top Mount Upflow 14” Furnacewith Bottom Mount Horizontal 14” Furnacewith Side Mount Plenum Box Upflow Furnacewith Plenum Box Horizontal 24” Furnace Downflow 24” Furnacewith Top Mount Upflow 24” Furnace On Standwith Bottom Mount Upflow Furnace Note: When transitioning betwe...
Page 5 - Mount Cabinet; ELECTRICAL SHOCK HAZARD; UNIT DAMAGE HAZARD
5 Mount Cabinet ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death.Before installing or servicing system, always turn off main power to system. There may be more than 1 disconnect switch. ! WARNING UNIT DAMAGE HAZARD Failure to follow this caution may res...
Page 6 - Wiring; Checking Air Purifier Operation
6 Sample Furnace Circuit Board Power Cordto EAC Terminals Use cable connector to secure power cord to cabinet Power Supply Connector Power Supply Use wire ties to secure power cord to power supply enclosure LHTOFFDLY ON OFF W2 BL W EAC-1 TERMINAL Y1 DHUM G COM 24V W W 1Y/Y2 R TEST/TWIN HUM 1 2 3 PLT...
Page 7 - MAINTENANCE; To replace the air purifier cartridge, complete the; Turn the heating and cooling system power; Turn heating and cooling system power off.
7 d. The power indicator light above the Air Purifier power switch should illuminate (see Fig. 10). e. Check to ensure the light goes off when the Infinity Air Purifier power switch is set to off, when the blower goes off,or when the HVAC system power is turned off. Infinity Control When the Infinit...
Page 8 - POINTS ARE SHARP! BE VERY CAREFUL DURING CLEANING.; TROUBLESHOOTING; SAFETY HAZARD
8 natural bristle) or vacuum cleaner with brush attachment. See Fig.11.Gently stroke the ionization pins on the top plane of each bar with enough brush depth to hit front and back tips of the points in the ionization array. Use a gentle back and forth brushing motion toclean any small accumulations ...
Page 9 - Table 1 – Troubleshooting
9 Be sure to inspect the unit before proceeding with these steps. Start with problem 1, then problem 2 and so on. Table 1 – Troubleshooting Problem: S Possible causes: S You should try this: 1 Infinity Air Purifier power indicator light located on the door is off. S Power switch is not in the on (cl...
Page 10 - SPECIFICATIONS AND DIMENSIONS; Table 2 – Specifications and Dimensions; SPECIFICATIONS
10 SPECIFICATIONS AND DIMENSIONS Table 2 – Specifications and Dimensions SPECIFICATIONS GAPAAXCC1625 GAPAAXCC2025 Color Taupe Metallic Taupe Metallic Cabinet Material 20 Ga. Powder Coated Steel 20 Ga. Powder Coated Steel Electrical 115v/60 Hz (from furnace EAC terminals) 115v/60 Hz (from furnace EAC...
Page 11 - Limited Warranty for Air Purifier
11 39004DP452 01/10 Limited Warranty for Air Purifier FOR WARRANTY SERVICE OR REPAIR: Contact the installer. You may find the installer’s name on the equipment or in your Owner’s Packet. For help, contact: CAC / BDP, Consumer Relations , P.O. Box 4808, Syracuse, New York 13221, Phone 1-800-227-7437 ...