Carrier Condensing gas furnace- User Manual

Carrier Condensing gas furnace

Carrier Condensing gas furnace– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
Page: / 22

Table of Contents:

  • Page 3 – FURNACE COMPONENTS; NOTE
  • Page 4 – MODEL NUMBER NOMENCLATURE; CARRIER ACCESSORIES
  • Page 6 – THERMOSTAT AND ZONING CONTROL OPTIONS
  • Page 7 – Concentric Vent Kit; between the furnace and a combustible floor when no coil box is
  • Page 9 – PHYSICAL DATA; PERFORMANCE DATA
  • Page 12 – CONDENSATE TRAP
  • Page 14 – DOWNFLOW SUBBASE; Assembled; MEDIA FILTER CABINET
  • Page 15 – ELECTRICAL DATA; TYPICAL WIRING SCHEMATIC
  • Page 18 – WINTER DESIGN TEMPERATURE AMBIENT*
  • Page 19 – CLEARANCE TO COMBUSTIBLES
  • Page 20 – TYPICAL INSTALLATIONS; Upflow Application
  • Page 22 – GUIDE SPECIFICATIONS; General; System Description; Infinity; Operating Characteristics
Loading the manual

1

58MVB INFINITY™ 96

DELUXE 4 --- WAY MULTIPOISE VARIABLE --- SPEED

TWO --- STAGE CONDENSING GAS FURNACE

Series 120 Input Rates: 40,000 thru 120,000 Btuh

Product Data

A05069

Comfort Heat

t

technology, the ultimate in

heating comfort . . .

The Carrier Infinity

t

96 with Comfort Heat

t

technology

achieves the optimum combination of comfort and efficency.
The Infinity

t

96 achieves industry--leading ultra--high efficiency

at up to 96.6 percent Annual Fuel Utilization Efficiency (AFUE).
Efficient performance is enhanced through the variable--speed

design. To maintain ideal comfort, Comfort Heat

t

technology

automatically adjusts the heating level, maximizing the use of low

heating levels that produce near silent furnace operation while

meeting the exact heating needs. This unit is designed to keep the
indoor temperature within less than 1 degree of the thermostat

setpoint. Because it operates in low heat most of the time, the
Infinity

t

96 uses up to 80% less power than single--capacity

furnaces.
In addition to providing ultimate comfort, the Infinity

t

96 has a

sealed combustion system. This system brings combustion air to

the furnace and vents flue gases outside the furnace in a safe
manner. Because it is sealed, operational noise is minimal. A sealed

combustion system also means fewer cold drafts and less air
infiltration.
The Infinity

t

96 is available in 6 heat/airflow combinations. The

unit has a 4--way multipoise design and can be installed in upflow,
downflow, or horizontal positions covering up to 24 different

applications. The Infinity

t

96 can be vented as a

Direct

vent/2--pipe furnace or as a non--direct vent/1--pipe application.
The versatile 4--way multipoise design in conjunction with variable
speed makes the Infinity

t

96 ideal for use with split system

cooling, including 2--speed units. A Carrier Infinity

t

air purifier,

humidifier, comfort ventilator, and Comfort Zone II control will
provide year round comfort and efficiency.
Designed for durability, comfort, and reliability, the Infinity

t

96 is

the ultimate in versatile, efficient comfort.

Carrier Infinity

r

System — When the Infinity

t

96

variable--speed gas furnace is matched with the Infinity

t

Control

and an air conditioner or heat pump, the homeowner will

experience the ultimate in Comfort Heat

t

and IdealHumidity

t

through unparalleled control of temperature, humidity, indoor air

quality, and zoning. The Carrier Infinity

t

System also provides

unprecedented ease of use through onscreen, text--based service
reminders and equipment malfunction alerts.
For even greater comfort and convenience, match the Infinity

t

96

furnace with an Infinity air conditioner or heat pump. This will

create a fully communicating system, requiring only 4 thermostat
wires between system components. In some cases, troubleshooting

can even be done from the outdoor unit without entering the home.
Optional remote access through telephone or Internet is also
available when combined with a remote connectivity kit.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - FURNACE COMPONENTS; NOTE

3 FURNACE COMPONENTS 12 6 16 15 17 8 10 6 5 1 13 14 2 4 3 79 11 1819 A02287 NOTE : S The 58MVB Furnace is built for use with natural gas. The furnace can be converted for propane gas with a factory--authorized and listedaccessory conversion kit. S Control location and actual controls may be differen...

Page 4 - MODEL NUMBER NOMENCLATURE; CARRIER ACCESSORIES

4 MODEL NUMBER NOMENCLATURE 58MVB 14 F 100 Deluxe 4 --- Way Multipoise Variable --- Speed Direct --- Vent (2 --- Pipe) or as a Non --- Direct --- Vent (1 --- Pipe) Two --- Stage Condensing Gas Furnace Media Filter Cabinet included Series Input Rates 040 --- 40,000 Btuh 060 --- 60,000 Btuh 080 --- 80...

Page 6 - THERMOSTAT AND ZONING CONTROL OPTIONS

6 THERMOSTAT AND ZONING CONTROL OPTIONS NON --- PROGRAMMABLE THERMOSTAT SELECTION TC --- NAC or TP --- NAC For use with 1 speed Air Conditioner --- _ F/ _ C, Auto Changeover TC --- NHC or TP --- NHC For use with 1 speed Air Conditioner --- _ F/ _ C, Auto Changeover TP --- NRH* For use with 2 speed A...

Other Carrier Models