Table of Contents:
- Page 3 – FURNACE COMPONENTS; NOTE
- Page 4 – MODEL NUMBER NOMENCLATURE; CARRIER ACCESSORIES
- Page 6 – THERMOSTAT AND ZONING CONTROL OPTIONS
- Page 7 – Concentric Vent Kit; between the furnace and a combustible floor when no coil box is
- Page 9 – PHYSICAL DATA; PERFORMANCE DATA
- Page 12 – CONDENSATE TRAP
- Page 14 – DOWNFLOW SUBBASE; Assembled; MEDIA FILTER CABINET
- Page 15 – ELECTRICAL DATA; TYPICAL WIRING SCHEMATIC
- Page 18 – WINTER DESIGN TEMPERATURE AMBIENT*
- Page 19 – CLEARANCE TO COMBUSTIBLES
- Page 20 – TYPICAL INSTALLATIONS; Upflow Application
- Page 22 – GUIDE SPECIFICATIONS; General; System Description; Infinity; Operating Characteristics
1
58MVB INFINITY™ 96
DELUXE 4 --- WAY MULTIPOISE VARIABLE --- SPEED
TWO --- STAGE CONDENSING GAS FURNACE
Series 120 Input Rates: 40,000 thru 120,000 Btuh
Product Data
A05069
Comfort Heat
t
technology, the ultimate in
heating comfort . . .
The Carrier Infinity
t
96 with Comfort Heat
t
technology
achieves the optimum combination of comfort and efficency.
The Infinity
t
96 achieves industry--leading ultra--high efficiency
at up to 96.6 percent Annual Fuel Utilization Efficiency (AFUE).
Efficient performance is enhanced through the variable--speed
design. To maintain ideal comfort, Comfort Heat
t
technology
automatically adjusts the heating level, maximizing the use of low
heating levels that produce near silent furnace operation while
meeting the exact heating needs. This unit is designed to keep the
indoor temperature within less than 1 degree of the thermostat
setpoint. Because it operates in low heat most of the time, the
Infinity
t
96 uses up to 80% less power than single--capacity
furnaces.
In addition to providing ultimate comfort, the Infinity
t
96 has a
sealed combustion system. This system brings combustion air to
the furnace and vents flue gases outside the furnace in a safe
manner. Because it is sealed, operational noise is minimal. A sealed
combustion system also means fewer cold drafts and less air
infiltration.
The Infinity
t
96 is available in 6 heat/airflow combinations. The
unit has a 4--way multipoise design and can be installed in upflow,
downflow, or horizontal positions covering up to 24 different
applications. The Infinity
t
96 can be vented as a
Direct
vent/2--pipe furnace or as a non--direct vent/1--pipe application.
The versatile 4--way multipoise design in conjunction with variable
speed makes the Infinity
t
96 ideal for use with split system
cooling, including 2--speed units. A Carrier Infinity
t
air purifier,
humidifier, comfort ventilator, and Comfort Zone II control will
provide year round comfort and efficiency.
Designed for durability, comfort, and reliability, the Infinity
t
96 is
the ultimate in versatile, efficient comfort.
Carrier Infinity
r
System — When the Infinity
t
96
variable--speed gas furnace is matched with the Infinity
t
Control
and an air conditioner or heat pump, the homeowner will
experience the ultimate in Comfort Heat
t
and IdealHumidity
t
through unparalleled control of temperature, humidity, indoor air
quality, and zoning. The Carrier Infinity
t
System also provides
unprecedented ease of use through onscreen, text--based service
reminders and equipment malfunction alerts.
For even greater comfort and convenience, match the Infinity
t
96
furnace with an Infinity air conditioner or heat pump. This will
create a fully communicating system, requiring only 4 thermostat
wires between system components. In some cases, troubleshooting
can even be done from the outdoor unit without entering the home.
Optional remote access through telephone or Internet is also
available when combined with a remote connectivity kit.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
3 FURNACE COMPONENTS 12 6 16 15 17 8 10 6 5 1 13 14 2 4 3 79 11 1819 A02287 NOTE : S The 58MVB Furnace is built for use with natural gas. The furnace can be converted for propane gas with a factory--authorized and listedaccessory conversion kit. S Control location and actual controls may be differen...
4 MODEL NUMBER NOMENCLATURE 58MVB 14 F 100 Deluxe 4 --- Way Multipoise Variable --- Speed Direct --- Vent (2 --- Pipe) or as a Non --- Direct --- Vent (1 --- Pipe) Two --- Stage Condensing Gas Furnace Media Filter Cabinet included Series Input Rates 040 --- 40,000 Btuh 060 --- 60,000 Btuh 080 --- 80...
6 THERMOSTAT AND ZONING CONTROL OPTIONS NON --- PROGRAMMABLE THERMOSTAT SELECTION TC --- NAC or TP --- NAC For use with 1 speed Air Conditioner --- _ F/ _ C, Auto Changeover TC --- NHC or TP --- NHC For use with 1 speed Air Conditioner --- _ F/ _ C, Auto Changeover TP --- NRH* For use with 2 speed A...