Carrier AQUAZONE 50PCH- User Manual
Carrier AQUAZONE 50PCH– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 3 – Table 1 — Physical Data — 50PCH,PCV Units; CAUTION
- Page 4 – UNIT HANGER DETAIL; Fig. 1 — 50PCH Unit Dimensions
- Page 5 – Fig. 2 — Typical Installation — 50PCH Units; UNIT HANGER ISOLATION DETAIL
- Page 6 – Fig. 3 — 50PCV Unit Dimensions
- Page 7 – Step 3 — Locate Unit —; Fig. 4 — Typical Vertical Installation of 50PCV Unit; Side Discharge to Back Discharge
- Page 8 – Fig. 7 — Horizontal Hanger Bracket; COMPRE; Fig. 8 — 50PCV Unit Mounted with
- Page 9 – Step 7 — Pipe Connections —; Table 2 — Metal Hose Minimum Bend Radii; NOTE: Unit does not need to be sloped toward drain.; Fig. 11 — Vertical Condensate Connection
- Page 15 – with Deluxe
- Page 16 – WH
- Page 18 – — WSHP Op
- Page 19 – Table 3 — 50PCH,PCV Unit Electrical Data; Fig. 21 — Typical Single-Phase Line Voltage Power Connection
- Page 20 – Step 9 — Wire Field Controls; only; NOTE: Low voltage connector may be removed for easy installation.; TERMINAL STRIP P2
- Page 21 – view; WARNING; OUTER JACKET
- Page 22 – System Checkout —; Table 8 — 50PCV Blower Performance with; COIL FACE VELOCITY; CONNECT THE BLUE WIRE TO:; Fig. 28 — Blower Speed Selection
- Page 25 – Operating Limits; When the disconnect switch is closed, high voltage is
- Page 26 – Table 13 — Operating Limits — 50PCH,PCV Units; Scroll Compressor Rotation —; Table 14 — Water Temperature Change; Dry Bulb
- Page 31 – Display Interface
- Page 32 – Table 26 — Coaxial Water Pressure Drop; Antifreeze —
- Page 33 – Table 28 — Antifreeze Percentages by Volume; OPERATION
- Page 36 – COMPLETE C AND DELUXE D BOARD
- Page 37 – Retry Mode —; Table 29 — Complete C Control Current LED
- Page 40 – Fig. 32 — Thermistor Nominal Resistance; Fig. 33 — FP1 and FP2 Thermistor Location; COAX —
- Page 41 – Table 32 — Troubleshooting
- Page 43 – APPENDIX A — WSHP OPEN SCREEN CONFIGURATION
- Page 44 – APPENDIX A — WSHP OPEN SCREEN CONFIGURATION (cont)
- Page 46 – APPENDIX A — WSHP SCREEN OPEN CONFIGURATION (cont)
- Page 52 – HEATING CYCLE ANALYSIS; = SUCTION TEMPERATURE – SUCTION SATURATION TEMPERATURE; SUBCOOLING; = DISCHARGE SATURATION TEMPERATURE – LIQUID LINE TEMPERATURE
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53500094-01
Printed in U.S.A.
Form 50PC-3SI
Pg 1
3-11
Replaces: 50PC-2SI
Installation, Start-Up, and
Service Instructions
CONTENTS
Page
SAFETY CONSIDERATIONS
. . . . . . . . . . . . . . . . . . .1,2
GENERAL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INSTALLATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22
Step 1 — Check Jobsite
. . . . . . . . . . . . . . . . . . . . . . . . 2
Step 2 — Check Unit
. . . . . . . . . . . . . . . . . . . . . . . . . . . 2
• STORAGE
• PROTECTION
• INSPECT UNIT
Step 3 — Locate Unit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
• FIELD CONVERSION OF DISCHARGE AIR
Step 4 — Mount the Unit
. . . . . . . . . . . . . . . . . . . . . . . . . 8
• HORIZONTAL UNITS
• VERTICAL UNITS
Step 5 — Check Duct System
. . . . . . . . . . . . . . . . . . . . 8
• SOUND ATTENUATION
• EXISTING DUCT SYSTEM
Step 6 — Install Condensate Drain
. . . . . . . . . . . . . . . 8
• HORIZONTAL UNITS
• VERTICAL UNITS
• VENTING
Step 7 — Pipe Connections
. . . . . . . . . . . . . . . . . . . . . . 9
• WATER LOOP APPLICATIONS
• GROUND LOOP APPLICATIONS
• INSTALLATION OF SUPPLY AND RETURN HOSE
KIT
Step 8 — Wire Field Power Supply
. . . . . . . . . . . . . . 10
• POWER CONNECTION
• SUPPLY VOLTAGE
• 208-VOLT OPERATION
• 460-VOLT OPERATION
Step 9 — Wire Field Controls
. . . . . . . . . . . . . . . . . . . . 20
• THERMOSTAT CONNECTIONS
• WATER FREEZE PROTECTION
• AIR COIL FREEZE PROTECTION
• ACCESSORY CONNECTIONS
• WATER SOLENOID VALVES
• WSHP OPEN WIRING
PRE-START-UP
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22,23
System Checkout
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
PSC Blower Speed Selection
. . . . . . . . . . . . . . . . . . 22
FIELD SELECTABLE INPUTS
. . . . . . . . . . . . . . . .24,25
Complete C Control Jumper Settings
. . . . . . . . . . . 24
Complete C Control DIP Switches
. . . . . . . . . . . . . . 24
Deluxe D Control Jumper Settings
. . . . . . . . . . . . . 24
Deluxe D Control DIP Switches
. . . . . . . . . . . . . . . . 24
Deluxe D Control Accessory Relay
Configurations
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Water Valve (Slow Opening)
. . . . . . . . . . . . . . . . . . . 25
Outside Air Damper (OAD)
. . . . . . . . . . . . . . . . . . . . 25
START-UP
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25-33
Operating Limits
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Scroll Compressor Rotation
. . . . . . . . . . . . . . . . . . . . . 26
Unit Start-Up Cooling Mode
. . . . . . . . . . . . . . . . . . . . . 26
Page
Unit Start-Up Heating Mode
. . . . . . . . . . . . . . . . . . . . . 30
Unit Start-Up with WSHP Open Controls
. . . . . . . . 30
Flow Regulation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Flushing
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Antifreeze
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Cooling Tower/Boiler Systems
. . . . . . . . . . . . . . . . . . 32
OPERATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33-36
Power Up Mode
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Units with Aquazone Complete C Control
. . . . . . . 33
Units with Aquazone Deluxe D Control
. . . . . . . . . . 33
Units with WSHP Open Multiple Protocol
. . . . . . . . 33
COMPLETE C AND DELUXE D BOARD
SYSTEM TEST
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36-38
Test Mode
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
WSHP Open Test Mode
. . . . . . . . . . . . . . . . . . . . . . . . . . 36
Retry Mode
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Aquazone Deluxe D Control LED Indicators
. . . . . 37
SERVICE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38-40
Filters
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Water Coil
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Condensate Drain Pans
. . . . . . . . . . . . . . . . . . . . . . . . . 38
Refrigerant System
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Compressor
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Fan Motors
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Condensate Drain Cleaning
. . . . . . . . . . . . . . . . . . . . . 38
Air Coil Cleaning
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Condenser Cleaning
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Checking System Charge
. . . . . . . . . . . . . . . . . . . . . . . 39
Refrigerant Charging
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Air Coil Fan Motor Removal
. . . . . . . . . . . . . . . . . . . . . 40
Replacing the WSHP Open Controller’s
Battery
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
TROUBLESHOOTING
. . . . . . . . . . . . . . . . . . . . . . . . 40-42
Thermistor
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Control Sensors
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
WSHP Open Controller
. . . . . . . . . . . . . . . . . . . . . . . . . . 40
APPENDIX A — WSHP OPEN SCREEN
CONFIGURATION
. . . . . . . . . . . . . . . . . . . . . . . . . . 43-48
50PCH,PCV START-UP CHECKLIST
. . . . . CL-1, CL-2
SAFETY CONSIDERATIONS
Installation and servicing of air-conditioning equipment can
be hazardous due to system pressure and electrical compo-
nents. Only trained and qualified service personnel should
install, repair, or service air-conditioning equipment.
Untrained personnel can perform basic maintenance func-
tions of cleaning coils and filters and replacing filters. All other
operations should be performed by trained service personnel.
When working on air-conditioning equipment, observe
precautions in the literature, tags and labels attached to the unit,
and other safety precautions that may apply.
IMPORTANT: Read the entire instruction manual before
starting installation.
AQUAZONE™
50PCH,PCV006-060
Compact High-Efficiency Water Source Heat Pumps
with PURON
®
Refrigerant (R-410A)
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
3 or an equivalent protective covering. Cap open ends of pipes stored on the jobsite. This precaution is especially important in areas where painting, plastering, or spraying of fireproof mate- rial, etc. is not yet complete. Foreign material that accumulates within the units can prevent proper star...
4 F RIGHT RETURN S TRAIGHT DI S CHARGE FRONT L N O M RIGHT RETURN FRONT LEFT/ S TRAIGHT DI S CHARGE C S P BACK DI S CHARGE CONDEN S ATE 3 / 4" FPT 3 . 3 " [ 83 . 8 MM] 0.7" [17. 8 MM] FRONT-VIEW E D K J 2 1 1.1 [27.9 MM] A CAP B S P RIGHT RETURN RIGHT VIEW - AIR COIL OPENING AIR COIL C T...
5 AccessoryElectric Heat(if applicable) Filter Access Return Loop Supply Loop Water OutWater In Integral hanger support-pre-attached in factory Field-supplied transition tominimize pressure loss 3/8" threaded rods (by others) Return Air(Ductworknot shown) Thermostat Wiring Power Wiring Balancing...