Table of Contents:
- Page 2 – TABLE OF CONTENTS
- Page 3 – MODEL NUMBER NOMENCLATURE; Cooling Capacities and Efficiencies
- Page 4 – PHYSICAL DATA
- Page 5 – OPTIONS AND ACCESSORIES; Electric Heaters
- Page 9 – ACCESSORY DIMENSIONS; Roof Curb for Small Cabinet; Roof Curb for
- Page 10 – 0XT SUGGESTED RIGGING; SELECTION PROCEDURE; Determine cooling and heating requirements at design
- Page 29 – Multiplication Factors
- Page 31 – TYPICAL PIPING AND WIRING
- Page 32 – APPLICATION DATA; Condensate trap; Ductwork; Balance Point Worksheet; Building Heat Loss, 1000BTUH
- Page 33 – ELECTRICAL DATA
- Page 35 – CONTROLS
- Page 36 – GUIDE SPECIFICATIONS
1
50XT
Infinity 15
t
SEER Single --- Packaged Heat Pump System
with Puron
r
(R--- 410A) Refrigerant
Single Phase
2 --- 5 Nominal Tons (Sizes 024 --- 060)
Product Data
A05307
Fig. 1 -- Unit 50XT
Single--Packaged Products with energy--saving features and
Puron
®
refrigerant.
S
Up to 15.5 SEER
S
Up to 8.0 HSPF
S
Up to 12 EER at 95
°
F (35
°
C) OD
S
Low Sound Levels
S
Variable--Speed Blower (Standard)
S
Factory--Installed TXV
S
Two--stage cooling and heat pump operation
FEATURES/BENEFITS
One--piece Heat Pump unit with optional electric heater, low
installation cost, dependable performance and easy maintenance.
Efficient operation
High--efficiency design
with SEERs (Seasonal Energy Efficiency
Ratio) of up to 15.5.
Puron
®
environmentally--sound refrigerant
is Carrier’s unique
refrigerant designed to help protect the environment. Puron is an
HFC refrigerant which does not contain chlorine that can harm the
ozone layer. Puron refrigerant is in service in millions of systems
proving highly reliable, environmentally sound performance.
Comfort Heat Pump System with IdealHumidity
t
featuring
Infinity
t
control variable--speed blower motor
and two--stage
cooling and heating that provides greater comfort, humidity
control, and energy efficiency.
Variable--speed blower motors
provide better comfort and energy
efficiency. You can expect up to 30 times better dehumidification;
economical constant airflow which provides improved indoor air
quality and more even temperatures from room to room; and
reduced indoor noise due to lower air velocity. In addition, you’ll
realize improved installation flexibility with 3 different airflow
choices for best overall comfort.
Easy installation
Factory--assembled package is a compact, fully self--contained heat
pump unit that is pre--wired, pre--piped, and pre--charged for
minimum installation expense. 50XT units are available in a
variety of standard capacity ranges. Units install easily on a rooftop
or at ground level.
Durable, dependable components
Compressors
have two stages of cooling and heating and are
designed for high efficiency. Each compressor is hermetically
sealed against contamination to help promote longer life and
dependable operation. Vibration isolation provides quiet operation.
Compressors have internal high--pressure and overcurrent
protection.
Convertible duct configuration
Unit is designed for easy use in either downflow or horizontal
applications. Each unit is easily converted from horizontal to
downflow with two duct covers (available as an accessory).
Downflow operation is easily provided in the field to allow vertical
ductwork connections. The basepan utilizes knockout style seals
on the bottom openings to ensure a positive seal in the horizontal
airflow mode.
Direct--drive, variable--speed blower motor
is standard on all
50XT models.
Direct--drive, PSC condenser fan motors
are designed to help
reduce energy consumption and provide for cooling operation
down to 55
°
F (12.7
°
C) outdoor temperature. Low--ambient
cooling is available below 55
°
F (12.7
°
C) when low--ambient
cooling is enabled in the User Interace (UI). Motormaster
®
II
low--ambient kit is not required.
Infinity
t
User Interface
is designed to work as a system with
Carrier’s single--packaged product.
Refrigerant system
is designed to provide dependability. Liquid
refrigerant filter driers are used to promote clean, unrestricted
operation. Each unit leaves the factory with a full Puron refrigerant
charge. Refrigerant service connections make checking operating
pressures easier.
Indoor and outdoor coils
are computer designed for optimum
heat transfer and cooling efficiency. The indoor coil is fabricated
from copper tube and aluminum fins and is located inside the unit
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for Carrier 50XT
Summary
2 for protection against damage. The outdoor coil is internallymounted on the top tier of the unit. Copper fin coils and pre--coated fin coils are available from the factory by special order. These coilsare recommended in applications where aluminum fins are likely to be damaged due to corrosion. Th...
3 MODEL NUMBER NOMENCLATURE 50XT 0 1 024 3 Type of Unit 50XT - Packaged Electric Heat Pump Nominal Cooling Capacity024 - 2 Ton 030 - 2.5 Ton 036 - 3 Ton 042 - 3.5 Ton 048 - 4 Ton 060 - 5 Ton N/A – – – Options BT - AL evap, vinyl condens CC - AL evap, CU condens CU - CU evap & condens TP - Base u...
4 PHYSICAL DATA UNIT SIZE 024 030 036 042 048 060 NOMINAL CAPACITY (ton) 2 2 --- 1/2 3 3 --- 1/2 4 5 OPERATING WEIGHT (lb) (kg) 405 184 435 197 464 210 476 216 492 223 535 243 COMPRESSOR Two --- Stage Scroll REFRIGERANT: PURON (R --- 410A) Quantity (lb) (kg) 10.3 4.7 11.5 5.2 9.7 4.4 14.0 6.4 15.5 7...