Carrier 50XT- Manual

Carrier 50XT

Carrier 50XT– Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
Page: / 38

Table of Contents:

  • Page 2 – TABLE OF CONTENTS
  • Page 3 – MODEL NUMBER NOMENCLATURE; Cooling Capacities and Efficiencies
  • Page 4 – PHYSICAL DATA
  • Page 5 – OPTIONS AND ACCESSORIES; Electric Heaters
  • Page 9 – ACCESSORY DIMENSIONS; Roof Curb for Small Cabinet; Roof Curb for
  • Page 10 – 0XT SUGGESTED RIGGING; SELECTION PROCEDURE; Determine cooling and heating requirements at design
  • Page 29 – Multiplication Factors
  • Page 31 – TYPICAL PIPING AND WIRING
  • Page 32 – APPLICATION DATA; Condensate trap; Ductwork; Balance Point Worksheet; Building Heat Loss, 1000BTUH
  • Page 33 – ELECTRICAL DATA
  • Page 35 – CONTROLS
  • Page 36 – GUIDE SPECIFICATIONS
Loading the manual

1

50XT

Infinity 15

t

SEER Single --- Packaged Heat Pump System

with Puron

r

(R--- 410A) Refrigerant

Single Phase

2 --- 5 Nominal Tons (Sizes 024 --- 060)

Product Data

A05307

Fig. 1 -- Unit 50XT

Single--Packaged Products with energy--saving features and
Puron

®

refrigerant.

S

Up to 15.5 SEER

S

Up to 8.0 HSPF

S

Up to 12 EER at 95

°

F (35

°

C) OD

S

Low Sound Levels

S

Variable--Speed Blower (Standard)

S

Factory--Installed TXV

S

Two--stage cooling and heat pump operation

FEATURES/BENEFITS

One--piece Heat Pump unit with optional electric heater, low
installation cost, dependable performance and easy maintenance.

Efficient operation

High--efficiency design

with SEERs (Seasonal Energy Efficiency

Ratio) of up to 15.5.

Puron

®

environmentally--sound refrigerant

is Carrier’s unique

refrigerant designed to help protect the environment. Puron is an
HFC refrigerant which does not contain chlorine that can harm the

ozone layer. Puron refrigerant is in service in millions of systems

proving highly reliable, environmentally sound performance.

Comfort Heat Pump System with IdealHumidity

t

featuring

Infinity

t

control variable--speed blower motor

and two--stage

cooling and heating that provides greater comfort, humidity
control, and energy efficiency.

Variable--speed blower motors

provide better comfort and energy

efficiency. You can expect up to 30 times better dehumidification;
economical constant airflow which provides improved indoor air

quality and more even temperatures from room to room; and
reduced indoor noise due to lower air velocity. In addition, you’ll

realize improved installation flexibility with 3 different airflow

choices for best overall comfort.

Easy installation

Factory--assembled package is a compact, fully self--contained heat

pump unit that is pre--wired, pre--piped, and pre--charged for
minimum installation expense. 50XT units are available in a

variety of standard capacity ranges. Units install easily on a rooftop

or at ground level.

Durable, dependable components

Compressors

have two stages of cooling and heating and are

designed for high efficiency. Each compressor is hermetically
sealed against contamination to help promote longer life and

dependable operation. Vibration isolation provides quiet operation.

Compressors have internal high--pressure and overcurrent
protection.

Convertible duct configuration

Unit is designed for easy use in either downflow or horizontal
applications. Each unit is easily converted from horizontal to

downflow with two duct covers (available as an accessory).

Downflow operation is easily provided in the field to allow vertical
ductwork connections. The basepan utilizes knockout style seals

on the bottom openings to ensure a positive seal in the horizontal
airflow mode.

Direct--drive, variable--speed blower motor

is standard on all

50XT models.

Direct--drive, PSC condenser fan motors

are designed to help

reduce energy consumption and provide for cooling operation
down to 55

°

F (12.7

°

C) outdoor temperature. Low--ambient

cooling is available below 55

°

F (12.7

°

C) when low--ambient

cooling is enabled in the User Interace (UI). Motormaster

®

II

low--ambient kit is not required.

Infinity

t

User Interface

is designed to work as a system with

Carrier’s single--packaged product.

Refrigerant system

is designed to provide dependability. Liquid

refrigerant filter driers are used to promote clean, unrestricted

operation. Each unit leaves the factory with a full Puron refrigerant

charge. Refrigerant service connections make checking operating
pressures easier.

Indoor and outdoor coils

are computer designed for optimum

heat transfer and cooling efficiency. The indoor coil is fabricated

from copper tube and aluminum fins and is located inside the unit

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Carrier 50XT

Summary

Page 2 - TABLE OF CONTENTS

2 for protection against damage. The outdoor coil is internallymounted on the top tier of the unit. Copper fin coils and pre--coated fin coils are available from the factory by special order. These coilsare recommended in applications where aluminum fins are likely to be damaged due to corrosion. Th...

Page 3 - MODEL NUMBER NOMENCLATURE; Cooling Capacities and Efficiencies

3 MODEL NUMBER NOMENCLATURE 50XT 0 1 024 3 Type of Unit 50XT - Packaged Electric Heat Pump Nominal Cooling Capacity024 - 2 Ton 030 - 2.5 Ton 036 - 3 Ton 042 - 3.5 Ton 048 - 4 Ton 060 - 5 Ton N/A – – – Options BT - AL evap, vinyl condens CC - AL evap, CU condens CU - CU evap & condens TP - Base u...

Page 4 - PHYSICAL DATA

4 PHYSICAL DATA UNIT SIZE 024 030 036 042 048 060 NOMINAL CAPACITY (ton) 2 2 --- 1/2 3 3 --- 1/2 4 5 OPERATING WEIGHT (lb) (kg) 405 184 435 197 464 210 476 216 492 223 535 243 COMPRESSOR Two --- Stage Scroll REFRIGERANT: PURON (R --- 410A) Quantity (lb) (kg) 10.3 4.7 11.5 5.2 9.7 4.4 14.0 6.4 15.5 7...