Carrier 40RU- Manual

Carrier 40RU

Carrier 40RU– Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
Page: / 40

Table of Contents:

  • Page 2 – INSTALLATION
  • Page 3 – Table 1A — 40RUA Physical Data, English — Cooling Units; Throwaway — Factory Supplied
  • Page 4 – Table 1B — 40RUA Physical Data, SI — Cooling Units
  • Page 5 – Table 1C — 40RUQ Physical Data, English — Heat Pump Units
  • Page 6 – Table 1D — 40RUA Physical Data, SI — Heat Pump Units
  • Page 7 – Table 1E — 40RUS Physical Data, English — Chilled Water Units; ODM
  • Page 8 – Table 1F — 40RUS Physical Data, SI — Chilled Water Units
  • Page 10 – UNIT
  • Page 12 – IMPORTANT; OVERHEAD SUSPENSION ACCESSORY — UNIT SIZE 25
  • Page 14 – V ERTI CA L I NS TALL ATI ON
  • Page 15 – Table 2 – Factory--Installed Nozzle and Distributor Data; Table 3 – Fitting Requirements
  • Page 18 – NOTE
  • Page 19 – ELECTRICAL SHOCK HAZARD; FIRE HAZARD; WARNING
  • Page 20 – Table 4 – Electrical Data, Standard Motors; Table 5 – Electrical Data, Alternate Motors; Legend and Notes for Tables 4 and 5
  • Page 21 – Table 6 – Fan Contactor Coil Data; UNIT OPERATION HAZARD; CAUTION
  • Page 22 – Fig. 19 -- Typical Fan Discharge Connections for Multiple Fan Units
  • Page 23 – Adjusting TXV for Superheat; INSTALLER / INSTALLATEUR; SERVICE
  • Page 24 – Table 7 – Lubricant Data; Multifak 2
  • Page 33 – Table 10B -- 40RU Standard Fan Performance Data —
  • Page 36 – Legend and Notes for Tables 10A and 10C; FACTORY-SUPPLIED PRESSURE DROP — ENGLISH; FACTORY-SUPPLIED PRESSURE DROP — SI
  • Page 39 – I. PRELIMINARY INFORMATION; ADDITIONAL ACCESSORIES; OUTDOOR UNIT
  • Page 40 – CHECK VOLTAGE IMBALANCE; COMP A1
Loading the manual

40RU

Packaged Air --- Handling Units

60 Hz

With Puron

R

(R --- 410A) Refrigerant

Sizes 25, 28, 30

Installation, Start --- Up and

Service Instructions

TABLE OF CONTENTS

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . .

PRE--INSTALLATION

2

. . . . . . . . . . . . . . . . . . . . . . . . .

Moving and Storage

2

. . . . . . . . . . . . . . . . . . . . . . . . . .

Rigging

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INSTALLATION

2–22

. . . . . . . . . . . . . . . . . . . . . . . . . .

General

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Uncrating

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Accessories

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Unit Positioning

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Unit Isolation

13

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Refrigerant and Chilled Water Piping Access

13

. . . . .

Refrigerant Piping

13

. . . . . . . . . . . . . . . . . . . . . . . . . .

Chilled Water Piping

17

. . . . . . . . . . . . . . . . . . . . . . . .

Condensate Drain

18

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Fan Motors and Drives

18

. . . . . . . . . . . . . . . . . . . . . . .

Power Supply and Wiring

19

. . . . . . . . . . . . . . . . . . . .

Connecting Ductwork

21

. . . . . . . . . . . . . . . . . . . . . . .

Return--Air Filters

21

. . . . . . . . . . . . . . . . . . . . . . . . . .

START--UP

23

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SERVICE

23–36

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Panels

23

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fan Motor Lubrication

24

. . . . . . . . . . . . . . . . . . . . . . .

Fan Shaft Bearings

24

. . . . . . . . . . . . . . . . . . . . . . . . . .

Centering Fan Wheel

24

. . . . . . . . . . . . . . . . . . . . . . . .

Fan Shaft Position Adjustment

24

. . . . . . . . . . . . . . . .

Individual Fan Wheel Adjustment

25

. . . . . . . . . . . . . .

Fan Belts

25

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fan Rotation

25

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fan Pulley Alignment

25

. . . . . . . . . . . . . . . . . . . . . . .

Pulley and Drive Adjustment

25

. . . . . . . . . . . . . . . . . .

Condensate Drains

25

. . . . . . . . . . . . . . . . . . . . . . . . . .

Return--Air Filters

25

. . . . . . . . . . . . . . . . . . . . . . . . . .

Chilled Water Coil Freeze Protection

26

. . . . . . . . . . .

Coil Removal

26

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Cleaning Cooling Coil

26

. . . . . . . . . . . . . . . . . . . . . . .

Cleaning Insulation

26

. . . . . . . . . . . . . . . . . . . . . . . . .

Replacing Filters

26

. . . . . . . . . . . . . . . . . . . . . . . . . . .

START--UP CHECKLIST

39--40

. . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service,

maintenance, or use can cause explosion, fire, electrical

shock or other conditions which may cause personal

injury or property damage. Consult a qualified installer,

service agency, or your distributor or branch for

information or assistance. The qualified installer or

agency must use factory--authorized kits or accessories

when modifying this product. Refer to the individual

instructions package

Follow all safety codes. Wear safety glasses and work

gloves. Use quenching cloths for brazing operations and

have a fire extinguisher available. Read these instructions

thoroughly and follow all warnings or cautions attached to

the unit. Consult local building codes and appropriate

national electrical codes (in USA, ANSI/NFPA70,

National Electrical Code (NEC); in Canada, CSA C22.1)

for special requirements.

It is important to recognize safety information. This is the
safety--alert symbol

. When you see this symbol on the

unit and in instructions or manuals, be alert to the

potential for personal injury.

Understand the signal words DANGER, WARNING,

CAUTION, and NOTE. These words are used with the

safety--alert symbol. DANGER identifies the most serious

hazards which

will

result in severe personal injury or

death. WARNING signifies hazards which

could

result in

personal injury or death. CAUTION is used to identify

unsafe practices, which

may

result in minor personal

injury or product and property damage. NOTE is used to

highlight suggestions which

will

result in enhanced

installation, reliability, or operation.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Carrier 40RU

Summary

Page 2 - INSTALLATION

2 ELECTRICAL SHOCK HAZARD Failure to follow this warning could cause in personal injury or death.Before performing service or maintenance operations on unit, always turn off main power switch to unit and install lockout tag. Unit may have more than one power switch. ! WARNING UNIT OPERATION AND SAFE...

Page 3 - Table 1A — 40RUA Physical Data, English — Cooling Units; Throwaway — Factory Supplied

3 Table 1A — 40RUA Physical Data, English — Cooling Units UNIT 40RUA* 25 28 30 NOMINAL CAPACITY (Tons) 20 25 30 OPERATING WEIGHT (lb) Base Unit with TXV 730 1050 1062 Plenum 225 325 325 FANS Qty...Diam. (in.) 2...15 2...18 2...18 Nominal Airflow (cfm) 8000 10000 12000 Airflow Range (cfm) 6000 – 1000...

Page 4 - Table 1B — 40RUA Physical Data, SI — Cooling Units

4 Table 1B — 40RUA Physical Data, SI — Cooling Units UNIT 40RUA* 25 28 30 NOMINAL CAPACITY (kW) 70 87 105 OPERATING WEIGHT (kg) Base Unit with TXV 331 477 482 Plenum 102 148 148 FANS Qty...Diam. (mm) 2...381 2...457 2...457 Nominal Airflow (L/s) 3775 4119 5663 Airflow Range (L/s) 2831 – 4719 3539 – ...

Other Carrier Models