Carrier 40QAC - Manual

Carrier 40QAC

Carrier 40QAC – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
Page: / 26

Table of Contents:

  • Page 2 – AC
  • Page 7 – Parts List; Indoor Unit; The following items are included with the indoor unit:; Table 1 – Installation Materials; Outdoor Unit; The following items are included with the outdoor unit:; Table 2 – Matched Systems; SYSTEM REQUIREMENTS; Clearances; Allow sufficient space around the indoor and outdoor unit for; Piping Lengths; Table 3 – Maximum Refrigerant Line Lengths; Pipe Sizes; Refer to table 4 for pipe sizes.; Table 4 – Pipe Sizes
  • Page 8 – Refrigerant Charge; Table 5 – Additional Charge; Metering Device; Table 6 – Accurator Sizes; Power and Connecting Cables -- Field Supplied; Control Wiring; User Interface -- Finished Goods Accessory; Table 7 – 38HDR / QRR Electrical Requirements
  • Page 9 – INSTALLATION
  • Page 10 – NOTE; clearance is required in back of unit.
  • Page 11 – INSTALL OUTDOOR UNIT; Mounting on Ground; CAUTION; Mounting Unit on Wall
  • Page 12 – Connection at Outdoor Unit; Complete Outdoor Power and Control Wiring; WARNING
  • Page 13 – ELECTRICAL SHOCK HAZARD; Power Wiring
  • Page 14 – ELECTRICAL DATA; Table 10 – 38HDR Electrical Data
  • Page 17 – Complete Indoor Piping; Connect Condensate Drain Line
  • Page 18 – Install Thermostat
  • Page 19 – Reassemble Indoor Unit; UNIT DAMAGE HAZARD; Service Valve
  • Page 20 – Deep Vacuum Method; MINUTES; MI; Triple Evacuation Method
  • Page 21 – AIR FILTERS
  • Page 22 – To clean the outdoor coil:; SERVICE
  • Page 23 – Before Calling for Service; FRESH AIR INSTALLATION OPTION; TROUBLESHOOTING; Table 14 – Troubleshooting
Loading the manual

40QAC / 38HDR

40QAQ / 38QRR

Ceiling --- Suspended Duct Free Split System

Sizes 018 to 060

Installation Instructions

the environmentally sound refrigerant

40QAC, QAQ Unit

38HDR, QRR Unit

NOTE

: Read the entire instruction manual before starting the

installation.

!

WARNING

UNIT OPERATION AND SAFETY HAZARD

Failure to follow this warning could result in personal injury or

equipment damage.
Puron refrigerant systems operate at higher pressures than

standard R--22 systems. To avoid damage to the unit or

possible personal injury, do not use R--22 service equipment or

components on Puron refrigerant equipment.

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,
or use can cause explosion, fire, electrical shock, or other

conditions which may cause death, personal injury, or property
damage. Consult a qualified installer, service agency, or your

distributor or branch for information or assistance. The qualified

installer or agency must use factory--authorized kits or accessories
when modifying this product. Refer to the individual instructions

packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,

and work gloves. Use quenching cloth for brazing operations.
Have fire extinguisher available. Read these instructions

thoroughly and follow all warnings or cautions included in

literature and attached to the unit. Consult local building codes and
current editions of the National Electrical Code ( NEC ) NFPA 70.

In Canada, refer to current editions of the Canadian electrical code
CSA 22.1.

Recognize safety information. This is the safety--alert symbol

!!

When you see this symbol on the unit and in instructions or
manuals, be alert to the potential for personal injury. Understand

these signal words; DANGER, WARNING, and CAUTION. These

words are used with the safety--alert symbol. DANGER identifies
the most serious hazards which

will

result in severe personal injury

or death. WARNING signifies hazards which

could

result in

personal injury or death. CAUTION is used to identify unsafe

practices which

would

result in minor personal injury or product

and property damage. NOTE is used to highlight suggestions
which

will

result in enhanced installation, reliability, or operation.

!

WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal

injury or death.
Before installing, modifying, or servicing system, main

electrical disconnect switch must be in the OFF

position. There may be more than 1 disconnect switch.

Lock out and tag switch with a suitable warning label.

PERSONAL INJURY AND EQUIPMENT DAMAGE

HAZARD

Failure to follow this caution may result in personal injury

and / or equipment damage.

DO NOT

operate the unit without a filter or with grille

removed.

CAUTION

!

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - AC

2 DIMENSIONS -- INDOOR NOTES: 1. Dimensions in [ ] are in millimeters.2. Direction of airflow. 3. Standard unit clearances are as follows: • 0 in. on top and rear • 3 in. on left side • 12 in. on right side • 36 in.on bottom (When facing unit discharge.) A08580 UNIT SIZE WEIGHT (lb) A B E F G Coolin...

Page 7 - Parts List; Indoor Unit; The following items are included with the indoor unit:; Table 1 – Installation Materials; Outdoor Unit; The following items are included with the outdoor unit:; Table 2 – Matched Systems; SYSTEM REQUIREMENTS; Clearances; Allow sufficient space around the indoor and outdoor unit for; Piping Lengths; Table 3 – Maximum Refrigerant Line Lengths; Pipe Sizes; Refer to table 4 for pipe sizes.; Table 4 – Pipe Sizes

7 These installation instructions cover the installation of the matchedsystems listed in table 2. Parts List Indoor Unit The following items are included with the indoor unit: Table 1 – Installation Materials Part No. Name of Part Qty. 1 Side Panels 2 2 Hex Head Bolts 4 3 Mounting Bracket 2 4 Piston...

Page 8 - Refrigerant Charge; Table 5 – Additional Charge; Metering Device; Table 6 – Accurator Sizes; Power and Connecting Cables -- Field Supplied; Control Wiring; User Interface -- Finished Goods Accessory; Table 7 – 38HDR / QRR Electrical Requirements

8 Refrigerant Charge The 38HDR and 38QRR units can be matched with multiple outdoor units and thus additional charge might be required whenmatched with the 40QAC or 40QAQ units. Table 5 – Additional Charge Additional Charge lb. (kg.) Unit Size 38HDR 38QRR 018 0.7 (0.32) 0.7 (0.32) 024 1.3 (0.59) 0.8...

Other Carrier Models