Carrier 38AK008- Troubleshooting Guide
Carrier 38AK008– Troubleshooting Guide, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 4 – Suction connection is sweat with liquid; *Weights are for aluminum coils
- Page 5 – – Liquid Line Data – 50Hz; must
- Page 7 – – Cooling Charging Chart
- Page 8 – SERVICE; Inspect unit interior at the beginning of each
- Page 9 – – September Coil Section; Compressor Removal; See Tables 1A and 1B for; CAUTION; Close both compressor service
- Page 10 – TROUBLESHOOTING GUIDE; SYMPTOM
- Page 11 – I. Preliminary Information; OUTDOOR UNIT
- Page 12 – CHECK VOLTAGE IMBALANCE; NOTES; Sanaye Sarma Afarin Iran; ناریا هیرفآامرس عیانص تکرش
1
38AK008,009,012
Air-Cooled Condensing Units
50 Hz
Installation, Start-Up and
Service Instructions
CONTENTS
Page
SAFETY CONSIDERATIONS
. . . . . . . . . . . .. . . . . . . . . 1
INSTALLATION
. . . . . . . . . . . . . . . . . . . . . . . ... . . . . . 1-6
Step 1 — Complete Pre-Installation Checks
. . ……. . . . 1
• UNCRATE UNIT
• INSPECT SHIPMENT
• CONSIDER SYSTEM REQUIREMENTS
Step 2 — Complete Refrigerant Piping
Connections
. . . . . . . . . . . . . . . . . . . . . . . . . . . .... . . . . . . . 4
• SIZE REFRIGERANT LINES
• FILTER DRIER AND MOISTURE INDICATOR
Step 3 — Make Electrical Connections
. . . . . . . . …... . . 5
• FIELD POWER SUPPLY
• FIELD CONTROL WIRING
START-UP
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8
Preliminary Checks
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Compressor Rotation
. . . . . . . . . . . . . . . . . . . . . . .. . . . . 7
Evacuate and Dehydrate
. . …………………………...... 7
Refrigerant Charge
. . . . . . . . . . . . . . . . . . . . . .. . . . . . . . 7
Low-Pressure/Loss-of-Charge Switch (LPS)
. . ……. . . 7
High-Pressure Switch (HPS)
. . . . . . . . . . . . . ... . . . . . . . 7
Refrigerant Service Ports
. . . . . . . . . . . . . . . . ... . . . . . . 7
Cooling
. . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . 7
Sequence of Operation
. . . . . . . . . . . . . . . . . . . ... . . . . . . 8
Oil Charge
. . . . . . . . . . . . . . . . . . . . . …… .. . . . . . . . . . 8
SERVICE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9
Cleaning
. . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . .. . . . 8
Lubrication
. . . . . . . . . . . . . . . . . . . . .. . . . . . . . . .. . . . . . 8
Condenser-Fan Adjustment
. . . . . . . . . . . . . . ….. . . . . 8
Compressor Removal
. . . . . . . . . . . . . . . . . . . …. . . . . . 9
Crankcase Heater
……………………. . . . . . ….. . . . . . 9
TROUBLESHOOTING GUIDE
. . . . . . . . . . . . . . . . 10
START-UP CHECKLIST
. . . . . . . . . . . . . .. . 11-12
SAFETY CONSIDERATIONS
Installing and servicing air-conditioning equipment can
be hazardous due to system pressure and electrical
components. Only trained and qualified service personnel
should install or service air-conditioning equipment.
When working on air-conditioning equipment, observe
precautions in literature and on tags and labels attached to
unit.
Follow all safety codes. Wear safety glasses and work
gloves. Use quenching cloth for brazing operations. Have
fire extinguisher available. Read these instructions
thoroughly.
Consult local building codes and National
Electrical Code(NEC) (U.S.A. Standard) for special
installation requirements.
WARNING
Before installing or servicing system, always turn off
main power to system and install lockout tag on
disconnect. There may be more than one disconnect
switch. Electrical shock can cause personal injury.
INSTALLATION
The 38AK008, 009, and 012 units use hermetic
compressors. See Table 1A or 1B for physical data.
Step 1
— Complete Pre-Installation Checks
UNCRATE UNIT — Remove unit packaging except for the
top, which should be left in place until after unit is rigged
into place.
INSPECT SHIPMENT — File claim with shipping
company if shipment is damaged.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for Carrier 38AK008
Summary
4 CONSIDER SYSTEM REQUIREMENTS • Consult local building codes and NEC for special installation requirements. • Allow sufficient space for airflow clearance, wiring, refrigerant piping, and unit servicing. See Fig. 1. • Locate unit so that condenser airflow is unrestricted on all sides and above. Ref...
5 FILTER DRIER AND MOISTURE INDICATOR —Moisture indicator and filter drier should be installed in liquid line. Do not use a receiver; there is none provided with unit and one should not be used. NOTE: System pressure must be relieved before removing caps. Recover refrigerant prior to brazing. Pass n...
7 START-UP Preliminary Checks 1. Field electrical power source must agree with unit nameplate acting. 2. Check that all internal wiring connections are tight and hat all barriers, covers, and panels are in place. Ensure no electrical wires are in contact with refrigerant tubing. 3. Ensure all servic...