Page 4 - Suction connection is sweat with liquid; *Weights are for aluminum coils

4 CONSIDER SYSTEM REQUIREMENTS • Consult local building codes and NEC for special installation requirements. • Allow sufficient space for airflow clearance, wiring, refrigerant piping, and unit servicing. See Fig. 1. • Locate unit so that condenser airflow is unrestricted on all sides and above. Ref...

Page 5 - – Liquid Line Data – 50Hz; must

5 FILTER DRIER AND MOISTURE INDICATOR —Moisture indicator and filter drier should be installed in liquid line. Do not use a receiver; there is none provided with unit and one should not be used. NOTE: System pressure must be relieved before removing caps. Recover refrigerant prior to brazing. Pass n...

Page 7 - – Cooling Charging Chart

7 START-UP Preliminary Checks 1. Field electrical power source must agree with unit nameplate acting. 2. Check that all internal wiring connections are tight and hat all barriers, covers, and panels are in place. Ensure no electrical wires are in contact with refrigerant tubing. 3. Ensure all servic...

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16

Summary

Page 4 - Table 2 — Weight Distribution; Step 2 — Rig and Mount the Unit; If it is necessary to roll unit into position, mount unit on; Table 3A — Refrigerant Piping Sizes — 60 Hz; Be sure unit panels are securely in place prior to rigging.

4 CONSIDER SYSTEM REQUIREMENTS• Consult local building codes and NEC for special instal-lation requirements. • Allow sufficient space for airflow clearance, wiring,refrigerant piping, and unit servicing. See Fig. 2. • Locate unit so that condenser airflow is unrestricted onall sides and above. Refer...

Page 5 - Fig. 3 — Rigging Label

5 UNIT 38 DIM. A DIM. B DIM. C DIM. D DIM. E DIM. F AK007 1 ′ -6 1 / 2 ″ [470.0] 1 ′ -2 3 / 4 ″ [375.0] —— 1 ′ -2 1 / 4 ″ [362] 1 ′ -4 5 / 16 ″ [415] 2 ′ -9 5 / 16 ″ [846.5] AK008 1 ′ -8 ″ [508.0] 1 ′ -6 1 / 2 ″ [470.0] —— 1 ′ -3 ″ [381] 2 ′ - 5 / 16 ″ [613] 3 ′ -5 7 / 16 ″ [1052.5] AK012 1 ′ -9 ″ [...

Page 6 - Step 4 — Make Electrical Connections; Fig. 4 — Typical Compressor Mounting; Fig. 5 — Power Wiring Connections

6 FILTER DRIER AND MOISTURE INDICATOR — The fil-ter drier is factory installed. Moisture indicator is field-suppliedand should be installed just after liquid line shutoff valve. Donot use a receiver; there is none provided with unit and oneshould not be used.NOTE: Unit is shipped with R-22 holding c...