Carrier 30RA - Manual
Carrier 30RA – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – ENGLISH; Contents; Page
- Page 3 – Physical data and electrical data - Model RA
- Page 4 – Physical data and electrical data - Model RH
- Page 5 – Dimensions and location of hydraulic connections (mm)
- Page 6 – General information and hydronic module; Unit installation
- Page 7 – Water connections; Typical water circuit diagram for units with hydronic module; Typical water circuit diagram for units without hydronic module
- Page 8 – Ethylene glycol curve
- Page 9 – Water pressure drop of the unit without hydronic module
- Page 10 – Electrical connections and refrigerant charge; Electrical connections; Liquid refrigerant charge
- Page 11 – Refrigerant charge and electronic control; Electronic control
- Page 12 – Compressor replacement; Description of unit protection devices
- Page 13 – Unit protection devices, operating limits and operating range; Table III: Pressure switch settings; 0RA - Operating limits; 0RH - Operating limits; Operating range - 30RA units
- Page 14 – General maintenance, maintenance and final recommendations; General maintenance; Maintenance
- Page 15 – Troubleshooting
AQUASNAP
30RA / 30RH
PRO-DIALOG
control
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
•
LL
O
Y
D
'S
R
E
G
IS
TE
R QUALIT
Y
A
S
S
U
R
A
N
C
E
I S O 9 0 0 1
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
GB - 1 30RA/30RH Air-cooled liquid chillers and reversible air-to-water heat pumpswith integrated hydronic module ENGLISH For the use of the control system, refer to the Pro-Dialog Plus control manual. Contents Page Physical data .........................................................................
30RA GB - 2 30RA 017 021 026 033 Power supply V-ph-Hz 400-3-50 / 400-3-50+N Voltage range V 360-440 Nominal power input* kW 6.43 8.57 9.56 12.39 Effective power input** kW 6.54 8.72 9.75 12.60 Nominal current drawn* A 10.75 15.50 18.80 24.55 Effective current drawn** A 10.95 15.75 19.10 24.95 Maximu...
GB - 3 30RH E N G L I S H 30RH 017 021 026 033 Power supply V-ph-Hz 400-3-50 / 400-3-50+N Voltage range V 360-440 Nominal power input* kW 6.21 7.95 9.13 11.83 Effective power input** kW 6.30 8.10 9.30 12.00 Nominal current drawn* A 10.75 14.80 18.70 23.65 Effective current drawn** A 10.90 15.05 19.0...