Carrier 30MPA - Manual

Carrier 30MPA

A technical manual for Carrier Aquasnap® liquid chillers with scroll compressors and ComfortLink™ controls covers their installation, operation, and integration into refrigeration systems. The document includes detailed specifications–such as dimensional layouts, weight distributions, and performance metrics (e.g., refrigerant capacity, compressor data)–for air-cooled (30MPA) and liquid-cooled (30MPW) models across multiple sizes. It also addresses critical topics like safety precautions during installation, piping configurations for fluid loops, water pressure drop characteristics in evaporators and condensers, and electrical wiring requirements, including phase voltage balance compliance with standards like ASHRAE and NEC.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 1 – Installation Overview and Safety Warnings
  • Page 2 – Model Nomenclature and Installation Requirements
  • Page 3 – Dimensional Specifications and Component Layouts
  • Page 4 – Unit Dimensional Views and Mounting Details
  • Page 5 – Performance Specifications Table
  • Page 6 – Detailed Technical Specifications in SI Units
  • Page 7 – Physical Installation Procedures
  • Page 8 – Liquid-Cooled System Piping Schematic
  • Page 9 – Chiller System Piping Diagram and Guidelines
  • Page 10 – Operational Installation Procedures
  • Page 11 – Condenser Water Pressure Drop Analysis
  • Page 12 – Evaporator Water Pressure Drop Analysis
  • Page 13 – Chilled Water Loop Filling and Cleaning
  • Page 14 – Electrical Connections and System Flushing
  • Page 15 – Electrical Data and Imbalance Guidelines
  • Page 16 – Low Voltage Control Wiring Details
Loading the manual
Page 1

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Catalog No. 04-53300054-01

Printed in U.S.A.

Form 30MP-1SI

Pg 1 910

1-10

Replaces: New

Installation Instructions

CONTENTS

Page

GENERAL

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

SAFETY CONSIDERATIONS

. . . . . . . . . . . . . . . . . . . 1,2

INSTALLATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16

Location

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Step 1

— Inspect Shipment

. . . . . . . . . . . . . . . . . . . . 2

Step 2

— Position the Unit

. . . . . . . . . . . . . . . . . . . . . 2

Step 3

— Place the Unit

. . . . . . . . . . . . . . . . . . . . . . . . 7

Step 4

— Check Compressor Mounting

. . . . . . . . 7

Step 5

— Make Piping Connections

. . . . . . . . . . . . 7

• 30MPA SYSTEM CONDENSER

• 30MPW CONDENSER DESCRIPTION

• 30MPW CONDENSER

• EVAPORATOR DESCRIPTION

• EVAPORATOR PIPING

• AIR SEPARATION

Step 6

— Fill the Chilled Water Loop

. . . . . . . . . . .13

• WATER SYSTEM CLEANING

• FILLING THE SYSTEM

Step 7

— Make Electrical Connections

. . . . . . . . .14

• FLOW SWITCH

• CONTROL BOX, POWER SECTION

• CONTROL BOX, CONTROLS SECTION

• CONTROL BOX, FIELD CONTROL WIRING

SECTION

• UNBALANCED 3-PHASE SUPPLY VOLTAGE

GENERAL

These installation instructions cover the 30MPA, MPW units

with

Comfort

Link controls. The 30MPA units are condenserless

units and the 30MPW units are all fluid cooled.

SAFETY CONSIDERATIONS

Installing, starting up, and servicing this equipment (Fig. 1

and 2) can be hazardous due to system pressures, electrical

components, and equipment location (roofs, elevated struc-

tures, etc.). Model number structure is shown in Fig. 3.

Only trained, qualified installers and service technicians

should install, start up, and service this equipment.

When working on the equipment, observe precautions in the

literature and on tags, stickers, and labels attached to the

equipment.
• Follow all safety codes.

• Wear safety glasses and work gloves.

• Use care in handling, rigging, and setting bulky

equipment.

.

WARNING

Electrical shock can cause personal injury and death. Shut

off all power to this equipment during installation. There

may be more than one disconnect switch. Tag all discon-

nect locations to alert others not to restore power until work

is completed.

Fig. 1 — 30MPA Unit

a30-5029

Fig. 2 — 30MPW Unit

a30-5030

AQUASNAP

®

30MPA,MPW015-045

Liquid Chillers

with Scroll Compressors

and

COMFORTLINK

™ Controls

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
Carrier
Model
30MPA
Document type
Manual
Language(s)
English
Pages
16
File size
3.6 MB
Format
PDF

Summary

Page 1 - Installation Overview and Safety Warnings

Installation instructions, table of contents, safety considerations, and warnings regarding power shutdown during installation for liquid chillers.

Page 2 - Model Nomenclature and Installation Requirements

Explanation of model number nomenclature indicating options like condenser type, size, voltage, and mounting kits, along with location requirements, clearance, weight support, and safety cautions for unit positioning.

Page 3 - Dimensional Specifications and Component Layouts

Dimensional specifications, component layouts, engineering drawings of internal components, mounting holes, clearance requirements, operating weights, and compressor counts for various unit models.

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.