Carrier 25HPA6 - Manual

Carrier 25HPA6

Carrier 25HPA6 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 2 – Check Equipment and Job Site; Unpack Unit; Install on a Solid, Level Mounting Pad; NOTE; Clearance Requirements
  • Page 3 – CAUTION; Make Piping Connections; WARNING; Outdoor Unit Connected to Factory--Approved Indoor
  • Page 4 – Table 2 – Accessory Usage; Yes
  • Page 5 – UNIT DAMAGE HAZARD; UNIT DAMAGE HAZARD; LEAK IN; MI; Make Electrical Connections; ELECTRICAL SHOCK HAZARD
  • Page 6 – Route Ground and Power Wires; Connect Ground and Power Wires; IMPORTANT; Compressor Crankcase Heater
  • Page 7 – Follow these steps to properly start up the system:; System Functions And Sequence Of Operation; Communication and Status Function Lights
  • Page 9 – GENERAL INFORMATION; Infinity Controlled low ambient cooling:; Accessory Liquid Solenoid with Infinity Communicating
  • Page 10 – Check Charge
  • Page 12 – Thermistor Sensor Comparison
  • Page 13 – Status Codes; EXAMPLE; OPERATION
  • Page 14 – Variable Speed Furnace and 2-- Stage Heat Pump
Loading the manual

25HPA6

Performance

t

Series 2 --- Stage Heat Pump

with Puron

r

Refrigerant

2 to 5 Nominal Tons

Installation Instruction

NOTE

: Read the entire instruction manual before starting the

installation.

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,

or use can cause explosion, fire, electrical shock, or other
conditions which may cause death, personal injury, or property

damage. Consult a qualified installer, service agency, or your

distributor or branch for information or assistance. The qualified
installer or agency must use factory--authorized kits or accessories

when modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,

and work gloves. Use quenching cloth for brazing operations.
Have fire extinguisher available. Read these instructions

thoroughly and follow all warnings or cautions included in
literature and attached to the unit. Consult local building codes and

current editions of the National Electrical Code ( NEC ) NFPA 70.

In Canada, refer to current editions of the Canadian electrical code
CSA 22.1.

Recognize safety information. This is the safety--alert symbol

!

!

.

When you see this symbol on the unit and in instructions or
manuals, be alert to the potential for personal injury.
Understand these signal words; DANGER, WARNING, and
CAUTION. These words are used with the safety--alert symbol.

DANGER identifies the most serious hazards which

will

result in

severe personal injury or death.

WARNING signifies hazards

which

could

result in personal injury or death. CAUTION is used

to identify unsafe practices which

may

result in minor personal

injury or product and property damage. NOTE is used to highlight

suggestions which

will

result in enhanced installation, reliability, or

operation.

Indoor Thermostat Control Options

Model

Infinity

Control

Standard

2 --- stage

Thermostat

25HPA6

Yes

Yes

!

WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal

injury or death.
Before installing, modifying, or servicing system, main

electrical disconnect switch must be in the OFF position

and install a lockout tag. There may be more than 1

disconnect switch. Lock out and tag switch with a

suitable warning label.

!

WARNING

UNIT OPERATION AND SAFETY HAZARD

Failure to follow this warning could result in personal injury

or equipment damage.
Puron

R

refrigerant systems operate at higher pressures than

standard R--22 systems. Do not use R--22 service equipment

or components on Puron

R

refrigerant equipment.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Check Equipment and Job Site; Unpack Unit; Install on a Solid, Level Mounting Pad; NOTE; Clearance Requirements

2 INSTALLATION RECOMMENDATIONS NOTE : In some cases noise in the living area has been traced to gas pulsations from improper installation of equipment. 1. Locate unit away from windows, patios, decks, etc. where unit operation sound may disturb customer. 2. Ensure that vapor and liquid tube diameter...

Page 3 - CAUTION; Make Piping Connections; WARNING; Outdoor Unit Connected to Factory--Approved Indoor

3 Operating Ambient The minimum outdoor operating ambient in cooling mode is 55 _ F (12.78 _ C) without low ambient cooling enabled, and the maximum outdoor operating ambient in cooling mode is 125 _ F (51.67 _ C). At line voltage of 208v (or below) and an outdoor ambient of 120 _ F (48.9 _ C) (and ...

Page 4 - Table 2 – Accessory Usage; Yes

4 Table 1 – Refrigerant Connections and Recommended Liquid and Vapor Tube Diameters (in.) UNIT SIZE LIQUID RATED VAPOR* Connection Diameter Tube Diameter Connection Diameter Tube Diameter 25HPA624 3/8 3/8 3/4 3/4 25HPA636 3/8 3/8 7/8 7/8 25HPA648 3/8 3/8 7/8 1 --- 1/8 25HPA660 3/8 3/8 7/8 1 --- 1/8 ...

Other Carrier Models