Campbell Hausfeld TF2136 - User Manual

Campbell Hausfeld TF2136

Campbell Hausfeld TF2136 Compressor – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
Page: / 24

Table of Contents:

  • Page 2 – SPRAYING; Installation
  • Page 3 – Operating Instructions; PUMP LUBRICATION; Recommended Oil; Do NOT fill the pump; STARTER SOLENOID (UNIT; Disconnect negative cable from; ENGINE LUBRICATION; Operation; Assembly; TANK
  • Page 4 – CRANKCASE BREATHER; Maintenance; CONTINUOUS RUN OPERATION
  • Page 5 – COMPONENTS; STORAGE; COMPRESSOR LUBRICATION; MAINTENANCE SCHEDULE
  • Page 6 – TROUBLESHOOTING CHART
  • Page 7 – Symptom
  • Page 8 – Limited Warranty
  • Page 9 – Instructions D’Utilisation; Description; DIRECTIVES DE SÉCURITÉ; DÉBALLAGE; Généralités sur la; PROPOSITION 65 CALIFORNIE; Lire attentivement tous; Voir la Garantie à la page 16 pour de; Compresseur D’Air Avec; AVERTISSEMENT; Ce compresseur/pompe n’est pas
  • Page 10 – PRÉCAUTIONS DE PULVÉRISATION
  • Page 11 – GRAISSAGE DU MOTEUR; Il est; Fonctionnement; GRAISSAGE DE LA POMPE; Huile recommandée; Montage; RÉSERVOIR
  • Page 12 – FONCTIONNEMENT CONTINU; Ne pas
  • Page 13 – Liste
  • Page 14 – GUIDE DE DÉPANNAGE; HORAIRE D’ENTRETIEN
  • Page 15 – Symptôme
  • Page 16 – Garantie Limitée
  • Page 17 – Manual de Instrucciones; Descripción; MEDIDAS DE SEGURIDAD; PARA DESEMPACAR; rales de Seguridad; PROPOSICIÓN DE CALIFORNIA 65; Lea con cuidado todos; Ver la Garantía en página 24 para; Compresores de; ADVERTENCIA SOBRE
  • Page 18 – PRECAUCIONES PARA ROCIAR
  • Page 19 – LUBRICACION DEL MOTOR; Antes de utilizarlo le debe; Funcionamiento; LUBRICACION DEL CABEZAL; Aceite recomendado; Ensamblaje; TANQUE; rales de
  • Page 20 – FUNCIONAMIENTO CONTINUO; No mezcle gasolina
  • Page 21 – Manual de instrucciones; Lista de repuestos; se le indica la; Lea las instrucciones
  • Page 22 – Problema; GUÍA DE DIAGNÓSTICO DE AVERÍAS; MANTENIMIENTO
  • Page 23 – GUÍA DE DIAGNÓSTICO DE AVERÍAS (CONTINUACIÓN)
  • Page 24 – Garantía Limitada
Loading the manual

Operating Instructions

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain

the product described. Protect yourself and others by observing all safety information. Failure to comply with

instructions could result in personal injury and/or property damage! Retain instructions for future reference.

1

Description

These air compressors are designed
to provide high air delivery where
electricity is not available. The
pump supplied with this unit has oil
lubricated bearings which cause a
small amount of oil carryover to be
present in the compressed air stream.
Applications requiring air free of
oil and water condensation should
have the appropriate filters installed.
Gasoline engine driven air compressors
are mounted on 30 gallon ASME code
horizontal tanks. Portable contractor
air compressors are mounted on twin
4 gallon tanks for low profile and
low center of gravity. All units are
equipped with a belt guard and an
idle down control to minimize fuel
consumption. Applications include tire
changers, inflation devices, pneumatic
tools and controls, nailers and spraying
equipment.

SAFETY GUIDELINES

This manual contains information
that is very important to know
and understand. This information
is provided for SAFETY and to
PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following ..

Danger indicates

an imminently

hazardous situation which, if not
avoided, will result in death or serious
injury.

Warning indicates

a potentially
hazardous situation which, if not
avoided, could result in death or serious
injury.

Caution indicates

a potentially
hazardous situation which, if not
avoided, may result in minor or
moderate injury.

Notice indicates

important
information, that if not followed, may
cause damage to equipment.

UNPACKING

After unpacking the unit, inspect
carefully for any damage that may
have occurred during transit. Make sure
to tighten fittings, bolts, etc., before
putting unit into service.

Do not operate

unit if damaged

during shipping, handling or use.

Damage may result in bursting and

cause injury or property damage.

General Safety

Information

CALIFORNIA PROPOSITION 65

CONTAINS LEAD.

May be harmful if

eaten or chewed. May generate

dust containing lead. Wash hands

after use. Keep out of reach of

children.

This product can expose

you to chemicals including

lead, which is known

to the State of California to

cause cancer and birth defects

or other reproductive harm. For

more information go to www.

P65Warnings.ca.gov.

Since the air compressor and other
components (pump, spray guns, filters,
lubricators, hoses, etc.) used make up
a high pressure pumping system, the
following safety precautions must be
observed at all times:
1. Read all manuals included

with this product
carefully. Be thoroughly
familiar with the controls
and the proper use of the
equipment.

2. Follow all local safety codes as well

as Occupational Safety and Health
Act (OSHA) in the United States.

3. Only persons well acquainted with

these rules of safe operation should
be allowed to use the compressor.

4. Keep visitors away and NEVER allow

children in the work area.

See Warranty on page 8 for

important information about

commercial use of this product.

Gasoline Engine Air

Compressors

© 2021 Campbell Hausfeld, MAT Industries, LLC.

IN259503AV Revision A

BREATHABLE AIR WARNING

This compressor/pump is NOT

This compressor/pump is NOT
equipped and should NOT be

equipped and should NOT be
used “as is” to supply breathing

used “as is” to supply breathing
quality air. For any application of

quality air. For any application of
air for human consumption, you

air for human consumption, you
must fit the air compressor/pump

must fit the air compressor/pump
with suitable in-line safety and

with suitable in-line safety and
alarm equipment. This additional

alarm equipment. This additional
equipment is necessary to

equipment is necessary to
properly filter and purify the air

properly filter and purify the air
to meet minimal specifications for

to meet minimal specifications for
Grade D breathing as described

Grade D breathing as described
in Compressed Gas Association

in Compressed Gas Association
Commodity Specification G 7.1

Commodity Specification G 7.1
-1966, OSHA 29 CFR 1910. 134,

-1966, OSHA 29 CFR 1910. 134,
and/or Canadian Standards

and/or Canadian Standards
Associations (CSA).

Associations (CSA).

DISCLAIMER OF WARRANTIES

DISCLAIMER OF WARRANTIES
IN TH

IN THE EVENT THE COMPRESSOR

E EVENT THE COMPRESSOR

IS USED FOR THE PURPOSE OF

IS USED FOR THE PURPOSE OF
BREATHING AIR APPLICATION

BREATHING AIR APPLICATION
AND PROPER IN-LINE SAFETY

AND PROPER IN-LINE SAFETY
AND ALARM EQUIPMENT IS NOT

AND ALARM EQUIPMENT IS NOT
SIMULTANEOUSLY USED, EXISTING

SIMULTANEOUSLY USED, EXISTING
WARRANTIES ARE VOIDED, AND

WARRANTIES ARE VOIDED, AND
THE MANUFACTURER DISCLAIMS

THE MANUFACTURER DISCLAIMS
ANY LIABILITY WHAT-SOEVER FOR

ANY LIABILITY WHAT-SOEVER FOR
ANY LOSS, PERSONAL

ANY LOSS, PERSONAL

INJURY OR

INJURY OR

DAMAGE.

DAMAGE.

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

IN259503AV

REVISION A

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SPRAYING; Installation

Operating Instructions 2 General Safety Information (continued) 5. Wear safety glasses and use hearing protection when operating the pump or unit. 6. Do not stand on or use the pump or unit as a handhold. 7. Before each use, inspect compressed air system, fuel system and electrical components for si...

Page 3 - Operating Instructions; PUMP LUBRICATION; Recommended Oil; Do NOT fill the pump; STARTER SOLENOID (UNIT; Disconnect negative cable from; ENGINE LUBRICATION; Operation; Assembly; TANK

Operating Instructions 3 PUMP LUBRICATION All moving parts must be guarded. All electrical covers must installed before turning on the power. Before operating compressor, fill to the center of the sight gauge (see Figure 3). Using any other type of oil may shorten pump life and damage valves. Recomm...

Page 4 - CRANKCASE BREATHER; Maintenance; CONTINUOUS RUN OPERATION

Operating Instructions 4 3. Open outlet valve and allow pressure in tank to drop to lower limit of control valve which is preset at 145 psi (2 stage) or 90 psi (single stage). At this point the control valve should close allowing the compressor to begin loading the tank instead of discharging throug...

Other Campbell Hausfeld Compressors Models