Guarantee This equipment is guaranteed against defects in materials andworkmanship. This guarantee applies for twelve months from date ofdelivery. We will repair or replace products which prove to be defectiveduring the guarantee period provided they are returned to us prepaid. Theguarantee will not...
Page 5 - Contents; Power Considerations; Figures
Contents 1. Introduction .................................................................. 1 2. Specifications .............................................................. 2 2.1 General Specifications ..............................................................................2 2.2 Output Speci...
Page 6 - Tables
Contents Tables 4-1. Datalogger to SDM-CVO4 Connections................................................. 4 4-2. Switch Position and Addresses ............................................................. 10 6-1. Description of Instruction 103 ............................................................
Page 8 - General Specifications
SDM-CVO4 4-Channel Current/Voltage Output Module The SDM-CVO4 is a synchronously addressed datalogger peripheral. Datalogger control ports 1, 2 and 3 are used to address the SDM-CVO4 and send out data that defines the desired voltage/current output of each of the four channels. The output levels are...
Page 9 - Output Specifications; Isolation Specifications
Instruction Manual 2.2 Output Specifications Voltage Mode: Range: 0 – 10,000 mV Resolution: 2.5 mV Maximum Output Current: 30 mA per channel. Minimum load current: 5 μ A if output < 200 mV. A ccuracy (+23 ° C) ± 0.02% of set voltage, + ( ± 2.5 mV). A ccuracy (-25 to +50 ° C) ± 0.13% of set voltag...
Page 10 - Connection to a Datalogger
SDM-CVO4 4-Channel Current/Voltage Output Module 3. Power Considerations The SDM-CVO4 power requirements are large compared to most Campbell Scientific products, especially when driving significant loads. Care must be taken to ensure that the power supply can cope with this higher demand. Alkaline b...
Page 12 - Output Device Connections
SDM-CVO4 4-Channel Current/Voltage Output Module 4.2 Output Device Connections For each output channel there are four terminals which are labelled V o , Id plus there are two ground ( ) connections per channel. The two ground terminals are internally connected; two are provided for convenience. 4.2....
Page 14 - Output Mode Setting
SDM-CVO4 4-Channel Current/Voltage Output Module 4.2.3 Shield and Ground Connections It is generally advisable to used shielded (screened) cable when connecting the output to any remote system to reduce the chances of noise pickup. The shield will only be effective if it is connected to a good groun...
Page 15 - SDM Address Setting
Instruction Manual Select channel(s) by fitting jumper (s) between appropriate terminals. (Current mode only.) Jumper shown fitted to ‘enable’ Channel 4. Jumper shown fitted in the unconnected ‘stored’ position. Figure 4-3. Location of Jumpers on Circuit Board Do not store the jumpers between any ot...
Page 16 - Safety Considerations
SDM-CVO4 4-Channel Current/Voltage Output Module Table 4-2. Switch Position and Addresses Switch Setting Base 4 Address 0 00 1 01 2 02 3 03 4 10 5 11 6 12 7 13 8 20 9 21 A 22 B 23 C 30 D 31 E 32 F 33 Use a screwdriver to select address Figure 4-4. Address Selection Switch The address switch has a he...
Page 18 - General Principles of Use; Voltage or Current Signalling
SDM-CVO4 4-Channel Current/Voltage Output Module this device is at the low end of its tolerance band (±10%), combined with the normal tolerance of flash test devices, then the spark gap could fire during a 1500 VAC flash test, which may cause an indication of failure. Testing at a slightly lower vol...
Page 19 - Datalogger Programming
Instruction Manual compensated for. With the SDM-CVO4 as an excitation source, any drift in its output accuracy, or of the logger measurement accuracy, can result in a combination of those errors. It is worth investigating, therefore, the exact requirements of the sensors you wish to use. For instan...
Page 21 - Edlog Program Examples
Instruction Manual If the SDM-CVO4 loses power for any reason, when power is restored the outputs will return to the default ‘off’ state. This will be held until the datalogger runs Instruction 103 again to update the output levels required. 6.2 Edlog Program Examples The following program examples ...
Page 24 - Providing Isolated Power Supplies to Sensors
SDM-CVO4 4-Channel Current/Voltage Output Module ; then set the value to –3000 13: Z=F (P30) 1: -3000 F 2: 00 Exponent of 10 3: 5 -- Z Loc [ ScldOut_1 ] 14: End (P95) 15: End (P95) ; Now update the SDM-CVO4 with the information ; for the four channels 16: SDM-AO4 (P103) 1: 4 Reps 2: 30 SDM Address 3...
Page 26 - CRBasic SDMCVO4 Instruction
SDM-CVO4 4-Channel Current/Voltage Output Module 6.3 CRBasic SDMCVO4 Instruction This instruction is used to control the SDM-CVO4 four channel current/voltage output device. Syntax SDMCVO4 ( CVO4Source, CVO4Reps, SDMAddress, CVO4Mode ) Remarks This instruction controls the SDM-CVO4, which outputs a ...
Page 30 - Campbell Scientific Companies
Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com [email protected] Campbell Scientific Africa Pty. Ltd. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.csafrica.co.za [email protected] Campbell Scientif...