Cadet SBFT2 - Manual

Cadet SBFT2

Cadet SBFT2 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
Page: / 6

Table of Contents:

  • Page 2 – Cadet Manufacturing Co. will repair or replace; These warranties do not apply:; Contact Cadet for information on Parts or Service.
  • Page 3 – Instrucciones de instalación del; Retire el tornillo que sujeta el conjunto del BTF existente (ter-; A D V E R T E N C I A
  • Page 4 – Cableado del zócalo/termostato; Elemento; Interruptor límite; Completar la instalación; GARANTIA LIMITADA DE UN AÑO:
  • Page 5 – General Programming Operation:; AUTO and MANUAL Modes:; Programming Instructions:; START UP; Setting the Time of Day and Day of Week:
  • Page 6 – Operación de programación general:; Consejos para ahorrar energía:; Instrucciones de programación:; INICIO; Fijar la hora del día y el día hábil:
Loading the manual

IMPORTANT INFORMATION

SAVE THESE INSTRUCTIONS

Installation Instructions

Tools Required: Phillips Screwdriver, Insulated Wire
Connectors (Wire Nuts®), Wire Strippers, Wire Cutters

TEL: 360-693-2505 Fax: 360-694-8668 P.O. Box 1675 Vancouver, WA 98668-1675

PLEASE READ THROUGH THESE INSTRUCTIONS BEFORE
PROCEEDING WITH INSTALLATION OF THE “SBFT2”
THERMOSTAT INTO A CADET SERIES “F” BASEBOARD

For All Applications

The thermostat needs to be mounted into the same junc-
tion box (wiring compartment) as the supplied electrical
power. If the supplied case ground conductor is not in this
junction box it will need to be relocated to the end wired.

The installation of the SMART-BASE thermostat may
require a slight adjustment of the panel across the front of
the heater, to allow the thermostat to fit into the junction
box unobstructed. To do so, remove both junction box cov-
ers and unlatch the bottom of the panel from its hangers.
(Use a rubber-coated tool, or hammer handle to remove
the panel. Carefully pry upward to remove.) Next, slide it
back out of the junction box opening to be used for the
thermostat until its edge is just hanging over the partition.
Hold the panel and snap it back on to its hangers. The
thermostat will now have enough room to fit into the junc-
tion box opening.

Replacing Existing BTF Thermostat Control

SBFT2

SMART-BASE

Thermostat

Installation Instructions

1. Remove screw attaching the existing BTF assembly

(thermostat and plate) to the baseboard case and care-
fully pull it back to expose the wiring and connections.
(Test with meter or circuit tester to verify that no electri-
cal power is present before proceeding.)

2. If the power supply has been brought into the base-

board at this junction box, undo the wiring connections
and remove the old thermostat assembly. Follow the
appropriate wiring diagram (“FIGURE A” for left end

attachment, “FIGURE B” for right end attachment) and
the following instructions “Baseboard/Thermostat
Wiring” below to connect the SBFT2 to the baseboard
and power supply.

3. If the power supply has not been brought into the base-

board at this junction box, remove the old thermostat
assembly by removing the wiring connections. The new
thermostat (SBFT2) must be located in the same junction
box as the supplied electrical power; therefore, strip 1/2"
of insulation from the two loose leads (created when the
thermostat was removed) and join the two wires back
together using a wire connector. Remove the end plate
from the other junction box and apply it to the junction
box where the thermostat was removed. Follow the
appropriate wiring diagram (“FIGURE A” for left end
attachment, “FIGURE B” for right end attachment) and
the following further instructions “Baseboard/Thermostat
Wiring” to connect the SBFT2 to the baseboard and
power supply.

As Part of New Installation

Install the Cadet “F” series baseboard heater according to
the installation instructions supplied with the product. Keep
in mind the SBFT2 thermostat needs to be mounted into the
same junction box (wiring compartment) as the supplied
electrical power. If the supplied case ground conductor is
not in this junction box it will need to be relocated to the
end wired.

IMPORTANT!

It is extremely impor-

tant that you verify

the electrical power
to be supplied to the

heater is the same

voltage as the heater.

Connecting a heater

to a lesser voltage

supply than is intend-

ed will reduce the

heater's output, and

connecting it to a

greater voltage sup-

ply than it is intended

can cause property

damage and personal

injury. The electron-

ic thermostat will
only function cor-

rectly on 240 & 208

volt circuits.

TM

W A R N I N G

Turn the electrical power off at the electrical panel
board (circuit breaker or fuse box) and lock or tag the
panel board door to prevent someone from turning on
power while you are working on the heater. Failure to
do so could result in serious electrical shock, burns,
or possible death.

©2005 Cadet Manufacturing Co.

Printed in U.S.A. 12/05 #720004

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Cadet SBFT2

Summary

Page 2 - Cadet Manufacturing Co. will repair or replace; These warranties do not apply:; Contact Cadet for information on Parts or Service.

Baseboard/Thermostat Wiring Thermostat in left junction box: (Figure A) 1. Locate and cut closed end splice of wires containing limit lead wire and return wire (wire behind deflector). Strip 1/2" of insulation fromthese two cut lead wires. a. Join the lead wire from the limit with the lead wire ...

Page 3 - Instrucciones de instalación del; Retire el tornillo que sujeta el conjunto del BTF existente (ter-; A D V E R T E N C I A

INFORMACIÓN IMPORTANTE CONSERVE ESTAS INSTRUCCIONES Instrucciones para la Instalación Herramientas necesarias: Destornillador Phillips, conectores dealambre aislados (WireNuts®), pelacables, cortadores de alambre TEL: 360-693-2505 Fax: 360-694-8668 P.O. Box 1675 Vancouver, WA 98668-1675 LEA COMPLETA...

Page 4 - Cableado del zócalo/termostato; Elemento; Interruptor límite; Completar la instalación; GARANTIA LIMITADA DE UN AÑO:

Cableado del zócalo/termostato Termostato en la caja de empalmes izquierda: (Figura A) 1. Localice y corte el empalme de extremo cerrado de los alambres que con- tiene el alambre conductor de límite y el de retorno (situado detrás deldeflector). Pele 1/2" de aislamiento de estos dos alambres con...