Cadet RM208 - Manual
Cadet RM208 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Installation Instructions; How do I install for new construction?; How do I install in an existing wall?; Route Supply Wires; READ ALL; Mount Wall Can
- Page 3 – Part Two; FIGURE 2; WARNING; FIGURE 1; Keep; YOUR WIRES WILL BE CONFIGURED LIKE THIS:; *Cut Blue Terminal from Red Wire and wrap with electrical tape.
- Page 4 – Symptom Problem; Troubleshooting Chart
- Page 5 – Nota: Termostato no incluido; ADVERTENCIA; INSTRUCCIONES IMPORTANTES; GUÍA PARA EL PROPIETARIO; The Register Plus
- Page 6 – Instrucciones para la instalación; LEA TODAS LAS; Parte Uno; Montaje de la cámara de pared
- Page 7 – Parte Dos; FIGURA 2; FIGURA 1; LOS ALAMBRES SE DEBEN CONFIGURAR ASÍ:; El terminal
- Page 8 – SÍNTOMA; Tabla de resolución de problemas
Features & Benefits
■
Thermal Safeguard:
•
High temperature manual reset:
turns off heater if normal operating
temperatures are exceeded
■
Commercial grade steel element
■
Powder coat paint process eliminates
sharp cutting edges
■
Five year extended warranty
■
Wall can designed for ease of
installation
■
Optional double pole field mount
thermostat kit available
■
Factory tested
MODELS:
RM202 RM208 RM108
RM151 RM162
Note: Thermostat not included
Dimensions in
inches (cm)
WARNING
Turn the electrical power off at the electrical
panel board (circuit breaker or fuse box) and lock
or tag the panel board door to prevent someone
from turning on power while you are working on
the heater. Failure to do so could result in serious
electrical shock, burns, or possible death.
SAVE THESE INSTRUCTIONS
1. Read all instructions before using this heater.
2. Read all information labels. Verify that the electrical supply
wires are the same voltage as the heater.
3. All electrical work and materials must comply with the
National Electric Code (NEC), the Occupational Safety and
Health Act (OSHA), and all state and local codes.
4. Connect the grounding pigtail (copper wire) provided in the
wall can to the supply ground wire.
5. If you need to install a new circuit or need additional wiring
information, consult a qualified electrician.
6. Protect electrical supply from kinks, sharp objects, oil,
grease, hot surfaces or chemicals.
7.
WARNING
Overheating or fire may occur. DO NOT install the heater in a
floor, ceiling or behind doors.
8.
WARNING
Fire or explosion may occur. DO NOT install heater in any
area where combustible vapors, gases, liquids, or excessive
lint or dust are present.
9.
WARNING
Burn Hazard. This heater is hot when in use. To avoid
burns, do not let bare skin touch hot surfaces. Use extreme
caution when any heater is used by or near children or
invalids.
10.
WARNING
Risk of Electrical Shock. Connect grounding lead to grounding
wire provided. Keep all foreign objects out of heater.
11.
WARNING
Risk of Fire. Do not block heater. Heater must be kept clear of
all obstructions: a minimum of 3 feet in front, 6 inches
above and on both sides. Heaters must be kept clean of lint,
dirt and debris. (See Maintenance Instructions).
12. Use this heater only as described in this manual. Any
other use not recommended by the manufacturer may
cause fire, electrical shock, or injury to persons.
IMPORTANT INSTRUCTIONS
Tools Required:
Phillips Screwdriver
Straight Screwdriver
Wire Strippers
Utility Knife
(4) 1 ½“ Wood Screws
(3) Insulated Wire Connectors
(1) Strain Relief Connector
OWNER’S GUIDE
The Register Plus
TEL: 360-693-2505 Fax: 360-694-8668 P.O. Box 1675 Vancouver, WA 98668-1675
Grill Front
Wall Can Front
4"T
10,16
2"T
5,08
3
/
4
"T
1,91
1"T
2,54
2
1
/
2
"T
6,35
3
3
/
8
"T
8,57
T
45˚T
Wall Can Side
5
7
/
8
"T
14,92
1"T
2,54
2"T
5,08
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Installation Instructions PLACEMENT: For best results install The Register Plus on an inside wall. Headers and bracing are not necessary. NOTE: The wall can must be installed in the TOP UP (horizontal) position only. Heater is notapproved for ceiling mount. THERMOSTAT: A thermostat is required. A Ca...
Element Wire Configuration (Multi-watt models RM151 or RM162 only) Cadet’s Multi-Watt RM heater offers a variety of heat output options. You must first determine thedesired wattage and then configure the heating element wire connections. The heater is shipped fromthe factory configured for 1600 Watt...
Operation & Maintenance Warranty How to operate your heater 1. Once installation is complete and power has been restored, turn the thermostat knob fully clockwise. 2. When the room reaches your comfort level, turn the thermostat knob counterclockwise until the heater turns off. The heater will a...