Page 3 - Notice; NOTICE; LANVIEW; is a registered trademark of Cabletron Systems, Inc.; Ethernet; is a trademark of Xerox Corp.; CompuServe; is a registered trademark of CompuServe, Inc.
Notice i NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or soft...
Page 4 - FCC NOTICE; This equipment has been tested and found to comply with; DOC NOTICE
Notice ii FCC NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOT...
Page 5 - VCCI NOTICE; Read the instructions for correct handling.
Notice iii brouillage radioélectrique édicté par le ministère des Communications du Canada. VCCI NOTICE This equipment is in the 1st Class Category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the Voluntary Control Council for Interfer...
Page 6 - EXCLUSION OF WARRANTY; EXCLUSION OF WARRANTY. Except as may be specifically
Notice iv EXCLUSION OF WARRANTY AND DISCLAIMER OF LIABILITY 1. EXCLUSION OF WARRANTY. Except as may be specifically provided by Cabletron in writing, Cabletron makes no warranty, expressed or implied, concerning the Program (including Its documentation and media). CABLETRON DISCLAIMS ALL WARRANTIES,...
Page 7 - CONTENTS; CHAPTER 1 INTRODUCTION
v CONTENTS CHAPTER 1 INTRODUCTION 1.1 USING THIS MANUAL ......................................................................... 1-11.2 THE 7H02-06 MODULE.......................................................................... 1-2 1.2.1 Cable Type and FEPIMs .........................................
Page 8 - Contents; APPENDIX A
vi Contents 5.3 SAFETY ......................................................................................................5-15.4 EMI .............................................................................................................5-15.5 IMMUNITY ..........................................
Page 9 - Introduction
1-1 CHAPTER 1 INTRODUCTION Welcome to Cabletron Systems 7H02-06 Fast Ethernet SmartSwitch ™ Interface Module Installation Guide. This guide is a simple reference for installing and using the 7H02-06 Module. Before installing the module, carefully read this manual to gain a full understanding of its ...
Page 10 - UTP operates at 10/100 Mbps, while Fiber operates at 100 Mbps.
1-2 Introduction 1.2 THE 7H02-06 MODULE The 7H02-06 Module provides six Fast Ethernet ports via 5 RJ45 connectors and one FEPIM. The 7H02-06 Module can be installed in: • The 7C03 MMAC SmartSwitch • The 7C04 Workgroup SmartSwitch Chassis • The 7C04-R Workgroup SmartSwitch Redundant Chassis The 7H02-...
Page 12 - The 7H02-06 Module incorporates the following LANVIEW LEDs:
1-4 Introduction Ring to be used with the 7H02-06 Module. These modules provide the capability to share data without the use of external bridges or routers. The 7C03 MMAC SmartSwitch is a unique module that can be installed in an MMAC Series chassis. The 7C04 Workgroup SmartSwitch and the 7C04-R Wor...
Page 15 - Appendix A; FEPIM MODULE SPECIFICATIONS
2-1 CHAPTER 2 NETWORK REQUIREMENTS Before installing Cabletron Systems 7H02-06 Module, review the network requirements outlined in this chapter. All requirements included in this chapter should be met to ensure satisfactory performance of the 7H02-06 Module. Failure to do so may result in unsatisfac...
Page 16 - Network Requirements; Transmitter power parameters are listed in Table 2-2.; Table 2-2. Transmitter Power Parameters; fiber
2-2 Network Requirements Transmitter power parameters are listed in Table 2-2. The link distance is up to 2 kilometers on the multimode fiber-optic cable as specified by ANSI MMF-PMD. Note: The link distance for Full Duplex is 2km; if Full Duplex is not being utilized, the link distance is 400 meter...
Page 17 - Pin Number; NA
Network Requirements 2-3 The link distance is up to 100 meters on unshielded Category 5 twisted pair cable as specified by ANSI TP-PMD. Table 2-3. FEPIM Pinouts Pin Number Represents Pin Number Represents 1 Transmit+ 5 NA 2 Transmit- 6 Receive- 3 Receive+ 7 NA 4 NA 8 NA
Page 19 - The procedure for removing the module depends upon the chassis
3-1 CHAPTER 3 INSTALLATION This chapter contains instructions for unpacking and installing the 7H02-06 Module in the 7C03, 7C04, 7C04-R MMAC SmartSwitch. Also included in the chapter are instructions for the front panel FEPIMs. 3.1 UNPACKING THE 7H02-06 MODULE Unpack the 7H02-06 Module by using the ...
Page 20 - Installation; Remove the blank front cover over the FEPIM slot.
3-2 Installation Figure 3-1. Module Bottom View 3. Remove the blank front cover over the FEPIM slot. 4. Install the FEPIM as shown in Figure 3-2. Ensure that the rear connector is seated firmly before tightening the three mounting screws. Note: Carefully push the FEPIM straight down once it is firml...
Page 21 - SmartSwitch; The
Installation 3-3 Figure 3-2. Installing an FEPIM 3.3 INSTALLING/REMOVING THE 7H02-06 MODULE The 7H02-06 Module is installed in: the 7C03 MMAC SmartSwitch, the 7C04 Workgroup SmartSwitch or the 7C04-R Workgroup SmartSwitch by using the following steps and referring to the appropriate figure. 3.3.1 In...
Page 22 - Remove the blank panel covering the slot in which the module; C03 MMAC SmartSwitch
3-4 Installation 1. Remove the blank panel covering the slot in which the module will be installed. All other slots in the 7C03 must remain covered to ensure proper airflow and cooling. 2. Slide the module into the slot. Make sure the printed circuit board (PCB) is between the card guides, slides in...
Page 23 - Before removing the; Figure 3-4. Removing the 7H02-06 Module from a 7C03 MMAC SmartSwitch; Screws
Installation 3-5 3.3.2 Removing the 7H02-06 Module from a 7C03 MMAC SmartSwitch To remove the 7H02-06 Module from a 7C03 MMAC SmartSwitch, follow the listed steps and refer to Figure 3-4. Note: Before removing the 7H02-06 Module, attach the wrist strap included with the module (instructions are prin...
Page 24 - Chassis
3-6 Installation 3.3.3 Installing the 7H02-06 Module in a 7C04 or 7C04-R Chassis To install the 7H02-06 Module in a 7C04 or 7C04-R Chassis, follow the listed steps and refer to Figure 3-5 and Figure 3-6, respectively. Notes: The 7H02-06 Module cannot be installed in the top slot of the 7C04 Chassis....
Page 26 - Ejector Tabs
3-8 Installation 3.3.4 Removing the 7H02-06 Module from a 7C04 or 7C04-R Chassis To remove the 7H02-06 Module from a 7C04 or 7C04-R Chassis, follow the listed steps and refer to Figure 3-7 and Figure 3-8 respectively. Note: Before removing the 7H02-06 Module, attach the wrist strap included with the...
Page 29 - Transmit
4-1 CHAPTER 4 TROUBLESHOOTING The 7H02-06 Module uses LANVIEW, Cabletron Systems built-in visual diagnostic and status monitoring system. With LANVIEW LEDs the status of each transmit and receive port on the 7H02-06 Module can be determined, at a glance. This section discusses the function and purpo...
Page 30 - Troubleshooting; Table 4-1 indicates the state of the receive port.; LED Color
4-2 Troubleshooting Table 4-1 indicates the state of the receive port. Table 4-2 indicates the state of the transmit port. Table 4-1. Port Receive LEDs LED Color State Green Link, no activity, port enabled Green (Flashing) Link, port disabled Yellow (Flashing) Link, activity, port enabled (flashing ...
Page 31 - Internal Processor: Intel i960 running at 33 MHz; FCC Part 15 Class A
5-1 CHAPTER 5 TECHNICAL SPECIFICATIONS This chapter includes the technical specifications for Cabletron Systems 7H02-06 module. Cabletron Systems reserves the right to change these specifications at any time without notice. 5.1 SYSTEM RESOURCES Internal Processor: Intel i960 running at 33 MHz Read O...
Page 32 - Technical Specifications; VCCI Class I; NETWORK INTERFACES; RJ45 connectors and 1 FEPIM.
5-2 Technical Specifications • VCCI Class I 5.5 IMMUNITY The 7H02-06 Module meets the requirements of EN50082-1 including: • IEC 801-2 ESD • IEC 803-1 radiated immunity • IEC 801-4 EFT/B 5.6 NETWORK INTERFACES 5 RJ45 connectors and 1 FEPIM. 5.7 SERVICE MTBF >200,000 hours MTTR <0.5 hour 5.8 PH...
Page 33 - Operating Temperature +5
Technical Specifications 5-3 5.8.3 Environmental Operating Temperature +5 ° to +40 ° C (+41 ° to +104 ° F) Storage Temperature -30 ° to +80 ° C (-22 ° to +160 ° F) Relative Humidity 5 to 95% (non-condensing)
Page 35 - side, the pairs are
A-1 APPENDIX A The 7H02-06 module uses Fast Ethernet Interface Modules (FEPIMs) to provide front panel cable connections. The FEPIMs are user-installable. See the section ‘Installing an FEPIM’ on page 3-1. A.1 FE-100TX The FE-100TX is an RJ45 connector supporting Unshielded Twisted Pair (UTP) cablin...
Page 36 - m fiber
A-2 Figure A-2. FE-100FX The transmitter power levels listed in Table A-1 are peak power levels after optical overshoot. A peak power meter must be used to correctly compare the values given below to those measured on any particular port. If power levels are being measured with an average power mete...