- Page 2 – DISASSEMBLY & CLEANING
- Page 3 – ASSEMBLY
- Page 4 – THOROUGH CLEANING OF THE PAF HOPPER (Once a week)
8. Wash components in a mild
solution of dish detergent using
a bristle brush. Rinse and dry
each item thoroughly before
reassembling.
NOTE: Parts must be thoroughly
dry before adding powder to the
hopper.
7. Slip the O-ring off the Whip-
per Chamber Receptacle and
remove the shaft seal.
4. Twist the Whipper Chamber
clockwise and pull it off the
Whipper Chamber Receptacle.
5. Pull the Frother off the Motor
Shaft. Notice the flat keyway on
the shaft and the matching key-
way inside the Frother. It is im-
portant that these two keyways
are lined up when reassembling.
6. Twist Whipper Chamber Re-
ceptacle clockwise and pull it off
the Motor Shaft. Wipe down all
inside surfaces.
USE & CARE INSTRUCTIONS for ULTRA-2 COLD DRINK DISPENSER WITH PAF DISPENSER
NOTICE - This guide is for quick reference only and is not intended to replace the information in the Operation Manual!
DISASSEMBLY & CLEANING
EMPTY ALL PRODUCT FROM THE ULTRA HOPPERS INTO A BUCKET OR CONTAINER BEFORE PROCEEDING!
1. Open the Cabinet Door and
allow the support arms to lock
in place. Door must remain
open during the entire cleaning
procedure.
3. Pull the Mixing Chamber out
of the Whipper Chamber.
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
43553.0000A 07/10 ©2010 Bunn-O-Matic Corporation
ULTRA-2 PAF
ULTRA-2 PAFA
(Page 1 of 4, Continued)
2. Place the power switch in
the OFF position. Slide the gate
shut on the powder hopper and
remove the hopper. Wipe the
hopper tray clean of powder
residue.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 2. Depress the hopper lock plunger, lift slightly. DISASSEMBLY & CLEANING Turn cooling to OFF selection. Empty all product from the hopper(s). Turn auger to OFF selection. 4.Pull the auger from the cool- ing drum. 6. CAUTION: Faucet valve is under spring tension. Spread one side of the handle ...
3 ASSEMBLY 2. Install the hopper seal over the flange at the rear of the cooling drum as shown. 3. Align the auger shafts with the augers. Push the augers as far as they will go and rotate them so the flat face of the auger shaft is aligned with the flat face of the auger nose. 5. Position the fauce...
4 1. Open the Cabinet Door and allow the support arms to lock in place. THOROUGH CLEANING OF THE PAF HOPPER (Once a week) 2. Slide the gate shut on the powder hopper and remove the hopper. Remove the Cover and empty the contents. 3. Pull the Ejector Elbow off the Hopper Base. Remove the Slide Gate f...