Page 2 - MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.; The agents, dealers or employees of BUNN; SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND.
2 41047 041108 BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) All equipment other than as specified below: 2 years parts and 1 year labor. 2) Electronic circuit and/or control boards: parts and labor for 3 years. 3) Compresso...
Page 3 - INTRODUCTION; CONTENTS
3 INTRODUCTION This equipment dispenses granita-type and cold liquid drinks on demand from separate hoppers. Operating controls are accessible only through password protection. CONTENTS Introduction & Warranty..........................................................................................
Page 4 - OPERATING CONTROLS; switch (upper left corner of the control pad)
4 OPERATING CONTROLS ULTRA-1 There are three of these switches that will be used for the operation of the dispenser. 1. switch (upper left corner of the control pad) This switch is the ON/OFF toggle switch which powers up the dispenser and the LCD display. When ON the Date and Time toggle back and f...
Page 6 - “GOURMET”; to scroll through the functions.; “ULTRA”
6 1 3 PROGRAMMING Using the menu-driven display on the front of the dispenser, the operator has the ability to alter or modify various parameters such as beverage consistency and set day/night “ON/OFF” times. The operator is also prompted to check a variety of periodic service functions or even a st...
Page 7 - PROGRAMMING THE DISPENSER; and procedures to program the various functions of the dispenser.
7 PROGRAMMING THE DISPENSER During normal operations, the Date, the Time, and the Serial Number toggle back and forth continuously. The following function screens are in the order they appear from the menu display. Each screen will have instructions and procedures to program the various functions of...
Page 9 - NO
9 P3678 Cleaning Guide This function leads the operator through a nine step cleaning process when answered YES (“ICE”). Depress GOURMET to display the next cleaning instruction. When entering this mode, the refrigeration system will automatically turn OFF. After step when hoppers are drained, the au...
Page 10 - Set Consistency; YES; ULTRA-1 models will only have one adjustment screen.
10 P3678 Set Consistency This function allows the operator to adjust the ice consistency, or torque of each auger when answered YES (“ICE”). Two screens will appear for left and right. The operator can scroll through a range of a minimum of 1 (ULTRA) to a maximum of 16 (ICE). Factory default is 10. ...
Page 11 - Select NEXT to repeat process for Right Auger Test.; MONTH 1; ULTRA-1 models will only have one test screen.
11 Test Augers This function tests the operation of forward and reverse of each auger motor. Left auger appears first. Press the ICE hidden switch to toggle between OFF, FORWARD and REVERSE. Press GOURMET hidden switch to repeat the operation for the right auger motor. A one minute time out will ret...
Page 12 - PASSWORD 0; ENGLISH
12 P3678 Password From this screen, the operator must know the password before moving on to the remaining functions. The range is from 0 - 9999 with the factory default being 0 . Set Language ? (Late Model Dispensers) The setting of the Set Language mode allows the operator to scroll thru a list of ...
Page 13 - Set Night Time/Set Day Time
13 This feature allows the machine to defrost the product during day time operation. The defrost minutes set- ting will select the defrost time period. The freeze minutes setting will select the freeze time between defrost periods. These modes when activated will function anytime the machine is in d...
Page 14 - Preventive Maintenance Complete?
14 Preventive Maintenance Complete? This function is used to reset a reminder message Preventive Maintenance Due every six months. The machine will not shut down if service is not performed. When the service is performed and the message is answered YES (ICE), the time and date is recorded for anothe...
Page 15 - NO EDIT YES; Late Model Dispensers
15 Day To Clean Off This function allows the operator to program a cleaning schedule from 1 to 14 days. The default screen is 0 or OFF. Selecting - or ULTRA will prompt the screen Days To Clean. Once a number of days is selected the screen will prompt two functions, CLEAN MESSAGE ONLY or CLEAN LOCKO...
Page 16 - Consistency Adjust Lock; YES THICK ADJUST
16 Consistency Adjust Lock This is an option of locking the Set Consistency function by selecting + (YES) or - (NO). YES THICK ADJUST (-) NEXT (+) NO THICK ADJUST (-) NEXT (+) 41047 040108
Page 17 - Switches Enabled; SWITCHES
17 Switches Enabled This function allows the operator to lockout the touch pad. Selecting + (ON) provides no time delay on switches except for the center (GOURMET) hidden switch. Selecting - (LOCKOUT) provides a five second hold to wake up the touch pad and a two minute time frame from last button p...
Page 19 - NO YES; AD MESSAGE; Ad Messages Enabled (Late Model Dispensers)
19 MODIFY MESSAGE ? NO YES SAVE ? NO EDIT YES SCROL THRU ALPHA NEXT-NEXT LETTER AD MESSAGE SETUP COMPLETE (MESSAGE) SCROL DONE NEXT AD MESSAGE (-) DISABLED (+) AD MESSAGE (-) ENABLED (+) Ad Messages Enabled (Late Model Dispensers) This function allows the operator to create an AD Message that will t...
Page 20 - Set Password; SET PASS WR 0; Enter Asset Number
20 Set Password This is the function to set the password using a range of 0 to 9999 (the factory default is 0). When the pass- word is set, the operator can only access the first four functions: Cleaning Guide, Set Consistency, Test Augers and Set Date & Time. SET PASS WR 0 (-) NEXT (+) SET PASS...
Page 22 - DISPLAY; The TEMP & TORQUE mode is typically used for service.
22 DISPLAY TEMP & TORQUE 0 0 36 36° 0 0 67 67°h TEMP & TORQUE Press and hold for five seconds the ULTRA and ICE hidden switches to display the TEMP & TORQUE. The tempera- ture of each cooling drum and the hot gas temperature will toggle back and forth. The auger torque is displayed conti...